Rapid Processing of Turner Designs Model 10-AU-005 Internally
Logged Fluorescence Data
AGENCY: Environmental Protection Agency.
ACTION: Notice of availability of a final document.
-----------------------------------------------------------------------
SUMMARY: This notice announces the availability of a final report
titled, Rapid Processing of Turner Designs Model 10-AU-005 Internally
Logged Fluorescence Data (EPA/600/R-04/053, August 2004), which was
prepared by the U.S. Environmental Protection Agency's (EPA) National
Center for Environmental Assessment (NCEA) of the Office of Research
and Development (ORD).
ADDRESSES: The document will be made available electronically through
the NCEA Web site (http://www.epa.gov/ncea). A limited number of copies
of the printed and CD-ROM version of the document will be available
from the EPA's National Service Center for Environmental Publications
(NSCEP), PO Box 42419, Cincinnati, OH 45242; telephone: 1-800-490-9198
or 513-489-8190; facsimile: 513-489-8695. Please provide your name,
your mailing address, the title and the EPA number of the requested
publication.
FOR FURTHER INFORMATION CONTACT: The Technical Information Staff,
National Center for Environmental Assessment/Washington Office (8623D),
U.S. Environmental Protection Agency, 1200 Pennsylvania Avenue, NW.,
Washington, DC 20460. Telephone: 202-564-3261; fax: 202-565-0050; e-
mail: nceadc.comment@epa.gov.
SUPPLEMENTARY INFORMATION: The U.S. EPA has used field fluorometers to
measure dye fluorescence when such dyes are injected into ground water
to trace groundwater flow. Typically, the data output from these off
the shelf fluorometers are not optimized for field use or subsequential
analysis. EPA has developed a methodology to enhance the usability of
fluorometer data and is sharing that information with the user
community.
This document and the related computer program, FLOWTHRU, provide a
method for rewriting data internally logged by a fluorometer used by
EPA (Turner Designs Model 10-AU-005 Field Fluorometer), thus optimizing
the utility of the instrument's stored data. Application of the
methodology provides the information necessary for rapid examination of
tracer test results and preparation of data sets for numerical
analysis. The new computer program bypasses block headers, reads the
downloaded data, identifies the time-concentration units used, and
relates the data to injection time. All preinjection time-concentration
data are accorded background data status and are written to a
background file with average temperature values included. All time
values recorded after injection time are rewritten into decimal time
using time units chosen by user. Additional features include options
for processing selected percentages, averaged time values, and a
smoothing routine that may be applied to the time-concentration data.
FLOWTHRU also allows users to view the data converted to decimal time
directly on the computer monitor without program interruption or to go
directly to a data plotting routine. Data plotting is rapid and clear
with a smooth line connecting each data point, and each data plot may
be saved as a file in a common format.