[Federal Register: October 25, 2005 (Volume 70, Number 205)]
[CORRECTIONS]
[Page 61698]
From the Federal Register Online via GPO Access [wais.access.gpo.gov]
[DOCID:fr25oc05-119]
[[Page 61698]]
DEPARTMENT OF ENERGY
Office of Energy Efficiency and Renewable Energy
10 CFR Parts 430 and 431
RIN 1904-AB54
Energy Conservation Standards for Certain Consumer Products and
Commercial and Industrial Equipment
Correction
In rule document 05-20701 beginning on page 60407 in the issue of
Tuesday, October 18, 2005, make the following corrections:
Sec. 430.32 [Corrected]
1. On page 60413, in Sec. 430.32(u), in the second table, under the
first column, in the 12th line, ``Lamp Power>20'' should read ``Lamp
Power>=20''.
Sec. 431.97 [Corrected]
2. On page 60415, in Sec. 431.97(b), in the table, in the fourth
column, the heading ``Efficiency level'' should read ``Efficiency
level[dagger]''.
3. On the same page, in the same section, in the same table, in the
same column, in the fifth entry, ``EER = 1 1.0*'' should read ``EER =
11.0*''.
4. On the same page, in the same section, in the same table, in the
third footnote, ``*EER'' should read ``[dagger]EER''.
Sec. 431.136 [Corrected]
5. On page 60416, in Sec. 431.136, the table is corrected to read
as follows:
----------------------------------------------------------------------------------------------------------------
Harvest rate Maximum condenser
Equipment type Type of cooling (lbs ice/24 Maximum energy use water use * (gal/100
hours) (kWh/100 lbs ice) lbs ice)
----------------------------------------------------------------------------------------------------------------
Ice Making Head............... Water............ < 500............. 7.80-0.0055H....... 200-0.022H.
Ice Making Head............... Water............ >=500 and <1436.. 5.58-0.0011H....... 200-0.022H.
Ice Making Head............... Water............ >=1436........... 4.0................ 200-0.022H.
Ice Making Head............... Air.............. < 450............. 10.26-0.0086H...... Not applicable.
Ice Making Head............... Air.............. >=450............ 6.89-0.0011H....... Not applicable.
Remote Condensing (but not Air.............. < 1000............ 8.85-0.0038H....... Not applicable.
remote compressor).
Remote Condensing (but not Air.............. >=1000........... 5.1................ Not applicable.
remote compressor).
Remote Condensing and Remote Air.............. < 934............. 8.85-0.0038H....... Not applicable.
Compressor.
Remote Condensing and Remote Air.............. >=934............ 5.3................ Not applicable.
Compressor.
Self Contained................ Water............ < 200............. 11. 40-0.019H...... 191-0.0315H.
Self Contained................ Water............ >=200............ 7.6................ 191-0.0315H.
Self Contained................ Air.............. < 175............. 18.0-0.0469H....... Not applicable.
Self Contained................ Air.............. >=175............ 9.8................ Not applicable.
----------------------------------------------------------------------------------------------------------------
H Harvest rate in pounds per 24 hours.
* Water use is for the condenser only and does not include potable water used to make ice.
[FR Doc. C5-20701 Filed 10-24-05; 8:45 am]
BILLING CODE 1505-01-D