[Federal Register: October 25, 2005 (Volume 70, Number 205)]
[CORRECTIONS]               
[Page 61698]
From the Federal Register Online via GPO Access [wais.access.gpo.gov]
[DOCID:fr25oc05-119]                         



[[Page 61698]]



DEPARTMENT OF ENERGY

Office of Energy Efficiency and Renewable Energy

10 CFR Parts 430 and 431

RIN 1904-AB54

 
Energy Conservation Standards for Certain Consumer Products and 
Commercial and Industrial Equipment

Correction

    In rule document 05-20701 beginning on page 60407 in the issue of 
Tuesday, October 18, 2005, make the following corrections:


Sec.  430.32  [Corrected]

    1. On page 60413, in Sec. 430.32(u), in the second table, under the 
first column, in the 12th line, ``Lamp Power>20'' should read ``Lamp 
Power>=20''.


Sec.  431.97  [Corrected]

    2. On page 60415, in Sec. 431.97(b), in the table, in the fourth 
column, the heading ``Efficiency level'' should read ``Efficiency 
level[dagger]''.
    3. On the same page, in the same section, in the same table, in the 
same column, in the fifth entry, ``EER = 1 1.0*'' should read ``EER = 
11.0*''.
    4. On the same page, in the same section, in the same table, in the 
third footnote, ``*EER'' should read ``[dagger]EER''.


Sec.  431.136  [Corrected]

    5. On page 60416, in Sec. 431.136, the table is corrected to read 
as follows:

----------------------------------------------------------------------------------------------------------------
                                                      Harvest rate                           Maximum condenser
        Equipment type           Type of cooling      (lbs ice/24      Maximum energy use  water use *  (gal/100
                                                         hours)        (kWh/100 lbs ice)          lbs ice)
----------------------------------------------------------------------------------------------------------------
Ice Making Head...............  Water............  < 500.............  7.80-0.0055H.......  200-0.022H.
Ice Making Head...............  Water............  >=500 and <1436..  5.58-0.0011H.......  200-0.022H.
Ice Making Head...............  Water............  >=1436...........  4.0................  200-0.022H.
Ice Making Head...............  Air..............  < 450.............  10.26-0.0086H......  Not applicable.
Ice Making Head...............  Air..............  >=450............  6.89-0.0011H.......  Not applicable.
Remote Condensing (but not      Air..............  < 1000............  8.85-0.0038H.......  Not applicable.
 remote compressor).
Remote Condensing (but not      Air..............  >=1000...........  5.1................  Not applicable.
 remote compressor).
Remote Condensing and Remote    Air..............  < 934.............  8.85-0.0038H.......  Not applicable.
 Compressor.
Remote Condensing and Remote    Air..............  >=934............  5.3................  Not applicable.
 Compressor.
Self Contained................  Water............  < 200.............  11. 40-0.019H......  191-0.0315H.
Self Contained................  Water............  >=200............  7.6................  191-0.0315H.
Self Contained................  Air..............  < 175.............  18.0-0.0469H.......  Not applicable.
Self Contained................  Air..............  >=175............  9.8................  Not applicable.
----------------------------------------------------------------------------------------------------------------
H Harvest rate in pounds per 24 hours.
* Water use is for the condenser only and does not include potable water used to make ice.


[FR Doc. C5-20701 Filed 10-24-05; 8:45 am]

BILLING CODE 1505-01-D