[Federal Register Volume 72, Number 11 (Thursday, January 18, 2007)]
[Proposed Rules]
[Pages 2217-2219]
From the Federal Register Online via the Government Publishing Office [www.gpo.gov]
[FR Doc No: E7-580]


-----------------------------------------------------------------------

CONSUMER PRODUCT SAFETY COMMISSION

16 CFR Part 1211


Safety Standard for Automatic Residential Garage Door Operators

AGENCY: Consumer Product Safety Commission.

ACTION: Notice of proposed rulemaking.

-----------------------------------------------------------------------

SUMMARY: The Consumer Product Safety Commission is proposing to amend 
16 CFR part 1211, Safety Standard for Automatic Residential Garage Door 
Operators, to reflect changes made by Underwriters Laboratories, Inc. 
in its standard UL 325.

DATES: Written comments in response to this document must be received 
by the Commission no later than February 20, 2007.

ADDRESSES: Comments should be filed by e-mail to [email protected]. 
Comments also may be filed by telefacsimile to (301) 504-0127 or they 
may be mailed or delivered, preferably in five copies, to the Office of 
the Secretary, U.S. Consumer Product Safety Commission, Room 502, 4330 
East-West Highway, Bethesda, Maryland 20814-4408; telephone (301) 504-
7923. Comments should be captioned ``Garage door operators.''

FOR FURTHER INFORMATION CONTACT: John Murphy, Directorate for 
Engineering Sciences, Consumer Product Safety Commission, 4330 East-
West Highway, Bethesda, Maryland, 20814-4408, telephone 301-504-7664 or 
e-mail: [email protected].

SUPPLEMENTARY INFORMATION: The Commission issued part 1211 on December 
21, 1992 to minimize the risk of entrapment by residential garage door 
openers. As mandated by section 203 of Public Law 101-608, subpart A of 
part 1211 codifies garage door operator entrapment provisions of 
Underwriter Laboratories, Inc. (``UL'') standard UL 325, third edition, 
``Door, Drapery, Louver and Window Operators and Systems.'' 
Subparagraph (c) of section 203 of Public Law 101-608 also required the 
Commission to incorporate into part 1211 any revisions that UL proposed 
to the entrapment protection requirements of UL 325, unless the 
Commission notified UL that the revision does not carry out the 
purposes of Public Law 101-608.
    Recently, UL revised some provisions of UL 325 in response to a 
request from Commission staff. The staff identified several incidents 
in which children became entrapped beneath a garage door that had been 
left partially open. In most of these incidents, a child tried to crawl 
under the partially open door and became stuck under the door. A 
bystander pressed the wall control button thinking the door would go up 
and release the child. Instead, the garage door moved down compressing 
and further entrapping the child. The Commission determined that the 
entrapment related revisions incorporated into the UL standard do carry 
out the purposes of Public Law 101-608. The proposed rule would revise 
part 1211 to reflect the changes UL made to UL 325. UL set an effective 
date of February 21, 2008 for these provisions in the UL standard. The 
Commission proposes the same effective date for these provisions in the 
CPSC standard.
    To address the same entrapment hazard, UL also added to its 
standard a requirement that the statement ``Never go under a stopped 
partially open door'' be added to garage door operator instruction 
manuals. The Commission is proposing to make this change in the CPSC 
standard as well. UL set an effective date of September 14, 2004 for 
this provision in UL 325. The Commission proposes that the instruction 
manual provision in the CPSC standard would become effective when it is 
published as a final rule.
    Pursuant to section 605(b) of the Regulatory Flexibility Act, 5 
U.S.C. 605(b), the Commission certifies that this rule will not have a 
significant impact on a substantial number of small

[[Page 2218]]

entities. The changes are minor. Moreover, UL has already made these 
changes to its UL 325 standard which is widely followed by the 
industry. The Commission also certifies that this rule will have no 
environmental impact. The Commission's regulations state that safety 
standards for products normally have little or no potential for 
affecting the human environment. 16 CFR 1021.5(c)(1). Nothing in this 
proposed rule alters that expectation.
    Public Law 101-608 contains a preemption provision. It states: 
``those provisions of laws of States or political subdivisions which 
relate to the labeling of automatic residential garage door openers and 
those provisions which do not provide at least the equivalent degree of 
protection from the risk of injury associated with automatic 
residential garage door openers as the consumer product safety rule'' 
are subject to preemption under 15 U.S.C. 2075. Public Law 101-608, 
section 203(f).

List of Subjects in 16 CFR Part 1211

    Consumer protection, Imports, Labeling, Reporting and recordkeeping 
requirements.
    Accordingly, 16 CFR part 1211 is proposed to be amended as follows:

PART 1211--SAFETY STANDARDS FOR AUTOMATIC RESIDENTIAL GARAGE DOOR 
OPENERS

    1. The authority citation for part 1211 continues to read as 
follows:

    Authority: Sec. 203 of Public Law 101-608, 104 Stat. 3110; 15 
U.S.C. 2063 and 2065.

    2. Section 1211.7 is amended by revising paragraphs (a), (b), (f) 
and (g) to read as follows:


Sec.  1211.7  Inherent entrapment protection requirements.

    (a)(1) Other than for the first 1 foot (305mm) of door travel from 
the full upmost position both with and without any external entrapment 
protection device functional, the operator of a downward moving 
residential garage door shall initiate reversal of the door within 2 
seconds of contact with the obstruction as specified in paragraph (b) 
of this section. After reversing the door, the operator shall return 
the door to, and stop at, the full upmost position. Compliance shall be 
determined in accordance with paragraphs (b) through (i) of this 
section.
    (2) The door operator is not required to return the door to, and 
stop the door at, the full upmost position when the operator senses a 
second obstruction during the upward travel.
    (3) The door operator is not required to return the door to, and 
stop the door at, the full upmost position when a control is actuated 
to stop the door during the upward travel--but the door can not be 
moved downward until the operator reverses the door a minimum of 2 
inches (50.8 mm).
    (b)(1) A solid object is to be placed on the floor of the test 
installation and at various heights under the edge of the door and 
located in line with the driving point of the operator. When tested on 
the floor, the object shall be 1 inch (25.4 mm) high. In the test 
installation, the bottom edge of the door under the driving force of 
the operator is to be against the floor when the door is fully closed.
    (2) For operators other than those attached to the door, a solid 
object is not required to be located in line with the driving point of 
the operator. The solid object is to be located at points at the 
center, and within 1 foot of each end of the door.
    (3) To test operators for compliance with requirements in 
paragraphs (a)(3), (f)(3), and (g)(3) of this section, Sec.  
1211.10(a)(6)(iii), and Sec.  1211.13(c), a solid rectangular object 
measuring 4 inches (102 mm) high by 6 inches (152 mm) wide by a minimum 
of 6 inches (152 mm)long is to be placed on the floor of the test 
installation to provide a 4-inch (102 mm) high obstruction when 
operated from a partially open position.
* * * * *
    (f)(1) An operator, using an inherent entrapment protection system 
that monitors the actual position of the door, shall initiate reversal 
of the door and shall return the door to, and stop the door at, the 
full upmost position in the event the inherent door operating 
``profile'' of the door differs from the originally set parameters. The 
entrapment protection system shall monitor the position of the door at 
increments not greater than 1 inch (25.4 mm).
    (2) The door operator is not required to return the door to, and 
stop the door at, the full upmost position when an inherent entrapment 
circuit senses an obstruction during the upward travel.
    (3) The door operator is not required to return the door to, and 
stop the door at, the full upmost position when a control is actuated 
to stop the door during the upward travel--but the door can not be 
moved downward until the operator reverses the door a minimum of 2 
inches (50.8 mm).
    (g)(1) An operator, using an inherent entrapment protection system 
that does not monitor the actual position of the door, shall initiate 
reversal of the door and shall return the door to and stop the door at 
the full upmost position, when the lower limiting device is not 
actuated in 30 seconds or less following the initiation of the close 
cycle.
    (2) The door operator is not required to return the door to, and 
stop the door at, the full upmost position when an inherent entrapment 
circuit senses an obstruction during the upward travel. When the door 
is stopped manually during its descent, the 30 seconds shall be 
measured from the resumption of the close cycle.
    (3) The door operator is not required to return the door to, and 
stop the door at, the full upmost position when a control is actuated 
to stop the door during the upward travel--but the door can not be 
moved downward until the operator reverses the door a minimum of 2 
inches (50.8 mm). When the door is stopped manually during its descent, 
the 30 seconds shall be measured from the resumption of the close 
cycle.
    3. Section 1211.10 is amended by revising paragraph (a)(1) and 
adding a new paragraph (a)(6) to read as follows:


Sec.  1211.10  Requirements for all entrapment protection devices.

    (a) General requirements. (1) An external entrapment protection 
device shall perform its intended function when tested in accordance 
with paragraphs (a)(2) through (4) and (6) of this section.
* * * * *
    (6)(i) An operator using an external entrapment protection device, 
upon detecting a fault or an obstruction in the path of a downward 
moving door, shall initiate reversal and shall return the door to, and 
stop the door at, the full upmost position.
    (ii) The door operator is not required to return the door to, and 
stop the door at, the full upmost position when an inherent entrapment 
circuit senses an obstruction during the upward travel.
    (iii) The door operator is not required to return the door to, and 
stop the door at, the full upmost position when a control is actuated 
to stop the door during the upward travel--but the door can not be 
moved downward until the operator has reversed the door a minimum of 2 
inches (50.8 mm).
    4. Section 1211.13 is amended by adding a new paragraph (c) to read 
as follows:


Sec.  1211.13  Inherent force activated secondary door sensors.

    (a) * * *
    (b) * * *
    (c) Obstruction test. For a door traveling in the downward 
direction,

[[Page 2219]]

when an inherent secondary entrapment protection device senses an 
obstruction and initiates a reversal, a control activation shall not 
move the door downward until the operator reverses the door a minimum 
of 2 inches (50.8 mm). The test is to be performed as described in 
Sec.  1211.7(b)(3).
    5. Section 1211.14 is amended by revising paragraph (b)(2) to read 
as follows:


Sec.  1211.14  [Amended]

    (a) * * *
    (b) Specific required instructions.
    (1) * * *
    (2) The User Instructions shall include the following instructions:
Important Safety Instructions

Warning--To reduce the risk of severe injury or death:

    1. Read and Follow all Instructions.
    2. Never let children operate, or play with door controls. Keep the 
remote control away from children.
    3. Always keep the moving door in sight and away from people and 
objects until it is completely closed. No One Should Cross the Path of 
the Moving Door.
    4. NEVER GO UNDER A STOPPED PARTIALLY OPEN DOOR.
    5. Test door opener monthly. The garage door MUST reverse on 
contact with a 1\1/2\ inch object (or a 2 by 4 board laid flat) on the 
floor. After adjusting either the force or the limit of travel, retest 
the door opener. Failure to adjust the opener properly may cause severe 
injury or death.
    6. For products requiring an emergency release, if possible, use 
the emergency release only when the door is closed. Use caution when 
using this release with the door open. Weak or broken springs may allow 
the door to fall rapidly, causing injury or death.
    7. Keep Garage Door Properly Balanced. See owner's manual. An 
improperly balanced door could cause severe injury or death. Have a 
qualified service person make repairs to cables, spring assemblies and 
other hardware.
    8. Save These Instructions.

    Dated: January 11, 2007.
Todd A. Stevenson,
Secretary, Consumer Product Safety Commission.
[FR Doc. E7-580 Filed 1-17-07; 8:45 am]
BILLING CODE 6335-01-P