[Federal Register: September 29, 2008 (Volume 73, Number 189)]
[Proposed Rules]
[Page 56513-56528]
From the Federal Register Online via GPO Access [wais.access.gpo.gov]
[DOCID:fr29se08-24]
========================================================================
Proposed Rules
Federal Register
________________________________________________________________________
This section of the FEDERAL REGISTER contains notices to the public of
the proposed issuance of rules and regulations. The purpose of these
notices is to give interested persons an opportunity to participate in
the rule making prior to the adoption of the final rules.
========================================================================
[[Page 56513]]
DEPARTMENT OF AGRICULTURE
Rural Utilities Service
7 CFR Parts 1728 and 1755
Standards and Specifications for Timber Products Acceptable for
Use by Rural Development Utilities Programs' Electric and
Telecommunications Borrowers
AGENCY: Rural Utilities Service, USDA.
ACTION: Proposed rule.
-----------------------------------------------------------------------
SUMMARY: The Rural Utilities Service, an agency delivering the United
States Department of Agriculture's (USDA) Rural Development Utilities
Programs, hereinafter referred to as USDA Rural Development or Agency,
proposes to revise its regulations on Electric and Telecommunications
Standards and Specifications for Materials, Equipment and Construction,
by codifying specifications for wood poles, stubs and anchor logs, wood
crossarms (solid and laminated), transmission timbers and pole keys,
and for quality control and inspection of timber products. The Agency
is proposing to update these specifications to conform with revisions
in the industry and to follow Agency policy on insurance requirements.
DATES: Written comments must be received by the agency or bear a
postmark or equivalent no later than November 28, 2008.
ADDRESSES: Submit comments by either of the following methods:
Federal eRulemaking Portal: Go to http://
www.regulations.gov and, in the lower ``Search Regulations and Federal
Actions'' box, select ``Rural Utilities Service'' from the agency drop-
down menu, then click on ``Submit.'' In the Docket ID column, select
RUS-07-Electric-0010 to submit or view public comments and to view
supporting and related materials available electronically. Information
on using Regulations.gov, including instructions for accessing
documents, submitting comments, and viewing the docket after the close
of the comment period, is available through the site's ``User Tips''
link.
Postal Mail/Commercial Delivery: Please send your comment
addressed to Michele Brooks, Director, Program Development and
Regulatory Analysis, USDA Rural Development, 1400 Independence Avenue,
STOP 1522, Room 5818-S, Washington, DC 20250-1522. Please state that
your comment refers to Docket No. RUS-07-Electric-0010.
Other Information: Additional information about USDA Rural
Development and its programs is available on the Internet at http://
www.rurdev.usda.gov/index.html.
Submit written comments to Michele L. Brooks, Director, Program
Development and Regulatory Analysis, USDA Rural Development, 1400
Independence Ave., SW., Stop 1522, Room 5818-S South Building,
Washington, DC 20250-1522.
An original and three copies of all comments (7 CFR 1700.4) are
required. All comments received will be made available for inspection
at room 1246-S, during regular business hours (7 CFR 1.27(b)).
FOR FURTHER INFORMATION CONTACT: Mr. H. Robert Lash, Transmission
Branch. Electric Staff Division, USDA Rural Development, Room 1246
S.T.O.P 1569, 1400 Independence Ave., SW., Washington, DC 20250-1569,
or telephone (202) 720-0486.
SUPPLEMENTARY INFORMATION:
Executive Order 12866
This proposed rule is exempted from the Office of Management and
Budget (OMB) review for purposes of Executive Order 12866 and,
therefore, has not been reviewed by OMB.
Executive Order 12988
This proposed rule has been reviewed in accordance with Executive
Order 12988, Civil Justice Reform. The Agency has determined that this
proposed rule meets the applicable standards provided in section 3 of
the Executive Order. In addition, all state and local laws and
regulations that are in conflict with this rule will be preempted; no
retroactive effect will be given to this rule; and, in accordance with
section 212(e) of the Department of Agriculture Reorganization Act of
1994 (7 U.S.C. 6912(e)) administrative appeal procedures, if any are
required, must be exhausted before an action against the Department or
its agencies.
Executive Order 12372
This proposed rule is excluded from the scope of Executive Order
12372, Intergovernmental Consultation, which may require consultation
with State and local officials. See the final rule related notice
entitled ``Department Programs and Activities Excluded from Executive
Order 12372,'' (50 FR 47034) advising that agency loans, loan
guarantees, and RTB bank loans were not covered by Executive Order
12372.
Regulatory Flexibility Act Certification
It has been determined that the Regulatory Flexibility Act is not
applicable to this proposed rule since the USDA Rural Development
Programs is not required by 5 U.S.C. 601 et seq.) or any other
provision of law to publish a notice of proposed rulemaking with
respect to the subject matter of this proposed rule.
Paperwork Reduction Act and E-Government Act
In accordance with the Paperwork Reduction Act of 1995 (44 U.S.C.
Chapter 35, as amended), USDA Rural Development invites comments on
this information collection for which approval from the Office of
Management and Budget (OMB) will be requested.
Comments on this proposal must be received by November 28, 2008.
Comments are invited on (a) whether the collection of information
is necessary for the proper performance of the functions of the agency,
including whether the information will have practical utility; (b) the
accuracy of the agency's estimate of burden including the validity of
the methodology and assumption used; (c) ways to enhance the quality,
utility and clarity of the information to be collected; and (d) ways to
minimize the burden of the collection of information on those who are
to respond, including through the use of appropriate automated,
electronic, mechanical, or other technological collection techniques on
other forms of information technology.
Comments may be sent to Michele L. Brooks, Director, Program
Development and Regulatory Analysis, USDA Rural Development, 1400
Independence Ave., SW., Stop 1522, Room 5818-S South Building,
Washington, DC 20250-1522.
Title: 7 CFR Parts 1728 and 1755.
[[Page 56514]]
OMB Control Number: 0572-0076.
Type of Request: Revision of a currently approved information
collection package.
Abstract: The Agency has a tremendous amount of interest in loan
security and protection of the Government's interest over the long term
life of a loan, which is generally secured by a first mortgage security
instrument and amortized over a period of up to 35 years. Therefore,
the Agency necessarily has a strong interest in the business,
financial, and operating aspects of its borrowers.
The Agency proposes to revise its regulations on Electric and
Telecommunications Standards and Specifications for Materials,
Equipment and Construction, by codifying specifications for wood poles,
stubs and anchor logs, wood crossarms (solid and laminated),
transmission timbers and pole keys, and for quality control and
inspection of timber products. The Agency is proposing to update these
specifications to conform with revisions in the industry and to follow
Agency policy on insurance requirements.
Respondents: Businesses and Not-for-profit institutions.
Estimated Number of Respondents: 25.
Estimated Number of Responses per Respondent: 1,600.
Estimated Total Annual Burden on Respondents: 40,000.
This estimated total annual burden is a decrease of 363 due to the
changes in the requirement that borrowers submit an annual summary
report and reserve stock notices on timber specifications.
Copies of this information collection can be obtained from MaryPat
Daskal, Program Development and Regulatory Analysis, at (202) 720-7853.
All responses to this information collection and recordkeeping
notice will be summarized and included in the request for OMB approval.
All comments will also become a matter of public record. USDA Rural
Development is committed to the E-Government Act, which requires
Government agencies in general to provide the public the option of
submitting information or transacting business electronically to the
maximum extent possible.
Send questions or comments regarding this burden or any other
aspect of these collections of information, including suggestions for
reducing the burden to Director, Program Development and Regulatory
Analysis, USDA Rural Development Programs, 1400 Independence Ave., SW.,
Room 5818-S Bldg., STOP 1522, Washington, DC 20250-1522.
National Environmental Policy Act Certification
The Administrator of the Agency has determined that this proposed
rule will not significantly affect the quality of the human environment
as defined by the National Environmental Policy Act of 1969 (42 U.S.C.
4321 et seq.). Therefore, this action does not require an environmental
impact statement or assessment.
Catalog of Federal Domestic Assistance
The program described by this proposed rule is listed in the
Catalog of Federal Domestic Assistance Programs under No. 10.850, Rural
Electrification Loans and Loan Guarantees, No. 10.851, Rural Telephone
Loans and Loan Guarantees, and No. 10.852, Rural Telephone Bank Loans.
This catalog is available on a subscription basis from the
Superintendent of Documents, the United States Government Printing
Office, Washington, DC 20402-9325, telephone number (202) 512-1800.
Unfunded Mandates
This proposed rule contains no Federal mandates (under the
regulatory provision of Title II of the Unfunded Mandates Reform Act)
for State, local, and tribal governments or the private sector. This
rule is not subject to the requirements of section 202 and 205 of the
Unfunded Mandates Reform Act.
Background
The Agency maintains bulletins that contain construction standards
and specifications for materials and equipment. These standards and
specifications apply to systems constructed by electric and
telecommunications borrowers in accordance with the loan contract, and
contain standard construction units, materials, and equipment units
used on electric and telecommunications borrowers' systems. Bulletins
1728F-700, ``Specification for Wood Poles, Stubs and Anchor Logs'';
1728H-701, ``Specification for Wood Crossarms (Solid and Laminated),
Transmission Timbers and Pole Keys''; and 1728H-702, ``Specification
for Quality Control and Inspection of Timber Products'', establish
standards for the manufacture and inspection of wood utility poles,
crossarms and poles keys.
The summary of the proposed major changes to these three bulletins
are as follows:
1. All references cited in these bulletins would be updated to the
latest edition.
2. The definition ``pole broker'' would be added to the list of
definitions to include as many organizations as possible to provide
borrowers a source from which they might purchase wood products.
3. Proposing to allow borrowers six months to notify treating
plants about poles not meeting the required preservative retention.
4. In accordance with Agency policy on insurance requirements for
contractors working for borrowers, the specification would be revised
to require manufacturers and inspection agencies to maintain certain
limits of liability and errors and omission insurance.
5. All poles would be required to be sterilized during the
conditioning or treating cycle. This sterilization should reduce the
number of poles with pre-treatment decay.
6. The independent inspection agency's identification on the face
of the pole would be branded.
7. The Agency would revise the qualifications for inspectors and
quality control personnel and would return to prior qualifications of
the specifications.
8. Provisions would be added to further clarify that wood products,
producers and inspection agencies maintain the greatest degree of
separation and eliminate any appearance of conflict of interest.
List of Subjects
7 CFR Part 1728
Electric power, Loan programs--energy, Reporting and recordkeeping
requirements, Rural areas.
7 CFR Part 1755
Loan programs--communications, Reporting and recordkeeping
requirements, Rural areas, Telephone.
For reasons set forth in the preamble, the Agency proposes to amend
7 CFR chapter XVII as follows:
PART 1728--ELECTRIC STANDARDS AND SPECIFICATIONS FOR MATERIALS AND
CONSTRUCTION
1. The authority citation for part 1728 continues to read as
follows:
Authority: 7 U.S.C. 901 et seq.; 1921 et seq., 6941 et seq.
2. Section 1728.97(b) is amended by revising the revision date of
Bulletin1728F-700.
Sec. 1728.97 Incorporation by reference of electric standards and
specifications.
(b) List of Bulletins.
* * * * *
Bulletin 1728F-700, Specification for Wood Poles, Stubs and Anchor
Logs [INSERT DATE OF PUBLICATION OF
[[Page 56515]]
THE FINAL RULE IN THE FEDERAL REGISTER]
* * * * *
3. Section 1728.201 is revised to read as follows:
Sec. 1728.201 Bulletin 1728H-701, Specification for Wood Crossarms
(Solid and Laminated), Transmission Timbers and Pole Keys.
(a) General Provisions. (1) This section implements contractual
provisions between the Agency and borrowers receiving financial
assistance. The contractual agreement between the Agency and its
borrowers requires the borrower's system to be constructed in
accordance with Agency accepted plans and specifications. Each electric
borrower must purchase only wood crossarms produced in accordance with
the specification in this section.
(2) Each electric borrower shall require each contractor to agree
in writing to furnish only materials produced in accordance with the
specification in this section.
(3) This specification describes the minimum acceptable quality of
wood distribution crossarms and transmission crossarms (hereinafter
called crossarms) that are purchased by or for borrowers. Where there
is conflict between this specification and any other specification
referred to in this section, this specification shall govern.
(4) Various requirements relating to quality control and inspection
are contained in Sec. 1728.202 of this part, Specification for Quality
Control and Inspection of Timber Products. Section 1728.201 of this
part and the American National Standards Institute (ANSI) O5.2, 1996,
(R2001) American National Standard for Wood Products--Structural Glued
Laminated Timber for Utility Structures, ANSI O5.3, 2002, American
National Standard for wood products Solid Sawn--Wood Crossarms and
Braces--Specification and Dimensions shall be followed exactly and
shall not be interpreted or subjected to judgment by the quality
control person or an independent inspector.
(5) The purchaser shall purchase from producers only material that
meets the requirements of this specification. Each purchaser shall use
a written purchase order to purchase material for use in financed
systems in order to ensure compliance with the standards and
specifications of this part. The written purchase order shall contain a
provision that specifically requires the producer to comply with the
provisions of this part. The purchase order shall contain a provision
that specifically requires the producer to make the treating plant and
storage areas available, during normal business hours, in order for
representatives of either the purchaser or this agency to inspect such
to determine compliance with the standards and specifications of this
part.
(6) The producer shall provide the inspectors with full information
(drawings, etc.) relating to the requirements contained in the purchase
order which is supplementary to this specification.
(7) The producer shall maintain, or have access to, adequate
laboratory facilities at or near the treating plant, and all chemical
tests, assays or analyses associated with the treatment shall be
independently performed in the laboratory by both the quality control
designee and the borrower's inspector. The producer may use a central
laboratory as accepted on a case-by-case basis.
(8) Inspection and treatment of all timber products produced under
this specification shall be performed after receipt of the order from
the purchaser, except as provided for reserve treated stock.
(9) The testing and inspection of the lamination process shall be
in accordance with American Institute of Timber Construction (AITC)
200-2004, Inspection Manual.
(10) With the exception of reserve treated stock, all invoices for
treated timber products shall be accompanied, in duplicate, by a copy
of the producer's Certificate of Compliance and a copy of either the
Independent Inspection Report or a Quality Assurance Plan Certificate.
The certificate shall be presented to the purchaser with the invoice.
For reserve treated stock, inspection reports shall be available from
the inspection agency. When shipped from reserve stock, the invoice
shall bear an endorsement and a further certification by the producer
that the material meets the requirements of this specification and any
supplementary requirements cited in the purchase order under which it
is purchased.
(11) Crossarms shall be warranted to conform to this specification.
If any crossarm is determined to be defective or does not conform to
this specification within 1 year after delivery to the borrower, it
shall be replaced as promptly as possible by the producer. In the event
of failure to do so, the purchaser may make such replacement and the
cost of the crossarm, at destination, shall be recoverable from the
producer.
(12) Crossarm producers shall take out and maintain liability
insurance and a bond or miscellaneous errors and omissions insurance
for not less than $1 million and $500,000, respectively. Upon request,
evidence of compliance shall be provided. The evidence shall be in the
form of a certificate of insurance signed by a representative of the
insurance company and include a provision that no changes in, or
cancellation of, will be made without the prior written notice to the
Director, Electric Staff Division, USDA Rural Development.
(b) Definitions.
Agency refers to Rural Utilities Service.
Arm is the structural wood member used to support electrical
conductors and equipment. Arm is used interchangeably with crossarm.
Certificate of compliance is a certification by an authorized
employee of the producer that the material shipped meets the
requirements of this specification and any supplementary requirements
specified in a purchase order from a borrower or the borrower's
contractor.
Crossarm is a structural wood member used to support electrical
conductors and equipment and is a term used interchangeably with arm.
Independent inspection is the examination of material by an
independent inspector employed by a commercial inspection agency.
Inspection is the examination of material in sufficient detail to
ensure conformity to all phases of the specification under which it was
purchased.
Lot is a quantity of crossarms of like size, conditioning, and
fabrication, usually making up one treating charge.
Producer is used to describe the party who manufactures and/or
treats crossarms.
Purchaser is the borrower or contractors acting as the borrower's
agent, except where a part of the specification specifically refers
only to the borrower or the contractor.
Quality control designee is an individual designated by the
producer to oversee proper operation of the manufacturer's internal
quality control system.
Reserve treated stock are timber products treated in accordance
with this specification, prior to and in anticipation of the receipt of
specific orders, and held in storage ready for immediate shipment.
Supplier is the producer, or in some cases, the distributor selling
crossarms to the borrower.
Treating plant is the organization that applies the preservative
treatment to the crossarms.
(c) Related specifications and standards incorporated by reference.
The following specifications and
[[Page 56516]]
standards are pending approval of incorporation by reference by the
Office of the Federal Register in accordance with 5 U.S.C. 552(a) and 1
CFR part 51. Copies of each reference are available for inspection
during normal business hours, room 1246-S, U.S. Department of
Agriculture, Washington, DC or, at the Office of the Federal Register,
800 North Capitol Street, NW., suite 700, Washington, DC. Copies of
these standards and specifications may be purchased from the addresses
shown below.
(1) West Coast Lumber Inspection Bureau, Standard No. 17, Grading
Rules for West Coast Lumber, January 1, 2004, available from West Coast
Lumber Inspection Bureau, P.O. Box 23145, Portland, Oregon 97281,
telephone (503) 639-0651, Fax (503) 684-8928. The Web address for West
Coast Lumber Inspection Bureau is http://www.wclib.org/.
(2) The following Southern Pine Inspection Bureau Standards,
available from Southern Pine Inspection Bureau, 4709 Scenic Highway,
Pensacola, Florida 32504-9094, telephone (850) 434-2611. The Web
address for the Southern Pine Inspection Bureau is http://
www.spib.org/.
(i) Standard Grading Rules for Southern Pine Lumber, available from
Southern Pine Inspection Bureau, 4709 Scenic Highway, Pensacola,
Florida 32504, telephone (850) 434-2611.
(ii) Special Product Rules for Structural, Industrial, and
Railroad-Freight Car Lumber.
(3) American Wood-Protection Association (AWPA), Book of Standards,
2007 edition, available from AWPA, P.O. Box 361784, Birmingham, AL
35236-1784, telephone 205 733-4077, http://www.awpa.com/, include the
following standards:
(i) A1-98, Standard Methods for Analysis of Creosote and Oil-Type
Preservatives.
(ii) A2-07, Standard Methods for Analysis of Waterborne
Preservatives and Fire-Retardant Formulations.
(iii) A3-05, Standard Methods for Determining Penetration of
Preservatives and Fire Retardants.
(iv) A5-05, Standard Methods for Analysis of Oil-Borne
Preservatives.
(v) A6-01, Method for the Determination of Oil-Type Preservatives
and Water in Wood.
(vi) A7-04, Standard Wet Washing Procedure for Preparing Wood for
Chemical Analysis.
(vii) A9-01, Standard Method for Analysis of Treated Wood and
Treating Solutions by X-Ray Spectroscopy.
(viii) A11-93, Standard Method for Analysis of Treated Wood and
Treating Solutions by Atomic Absorption Spectroscopy.
(ix) U1-07, Use Category System: User Specification for Treated
Wood.
(x) T1-07, Use Category System: Processing and Treatment Standard.
(xi) M1-07, Standard for the Purchase of Treated Wood Products.
(xii) M2-07, Standard for Inspection of Treated Timber Products.
(xiii) M3-05, Standard Quality Control Procedures for Wood
Preserving Plants.
(xiv) M4-06, Standard for the Care of Preservative-Treated Wood
Products.
(xv) P1/P13-06, Standards for Creosote Preservatives.
(xvi) P5-07, Standards for Waterborne Preservatives.
(xvii) P8-06, Standards for Oil-Borne Preservatives, and
(xviii) P9-06, Standards for Solvents and Formulations for Organic
Preservative Systems.
(4) American Institute of Timber Construction (AITC) 200-2004,
Inspection Manual, 2004 edition, available from AITC, 7012 S. Revere
Park Way, Englewood, Colorado 80112, telephone (303) 792-9559, Web
address: https://www.aitc-glulam.org/index.asp.
(5) American National Standards Institute (ANSI) O5.2-1996 (R2001),
American National Standard for Wood Products--Structural Glued
Laminated Timber for Utility Structures, available from ANSI, 25 West
43rd Street, New York, New York 10036, telephone (212) 642-4900, Web
address: http://www.ansi.org/.
(6) American Society for Testing and Materials (ASTM) D9-05,
Standard Terminology Relating to Wood, available from ASTM, 100 Barr
Harbor Dr. West, PO Box C700, Conshohocken, PA 19428-2959, telephone
number (610) 832-9585, Web address: http://www.astm.org.
(d) Independent Inspection Plan. This plan or a Quality Assurance
Plan, as described in paragraph (e) of this section, is acceptable for
supplying crossarms. All crossarms purchased under the Independent
Inspection Plan, for use on an Agency financed system shall be
inspected by a qualified independent inspector in accordance with Sec.
1728.202 of this part.
(1) The borrower has the prerogative to contract directly with the
inspection agency for service. The borrower should, where practical,
select the inspection agency so that continual employment is dependent
only on performance acceptable to the borrower and in accordance with
this specification. The selected inspection agency shall not be allowed
to subcontract the service to any other inspection agency.
(2) The producer shall not be permitted to be a party to the
selection of the inspection agency by the borrower and shall not
interfere with the work of the inspector, except to provide
notification of the readiness of material for inspection. To obtain
inspection services for reserve stock, the producer may deal directly
with the inspection agency. Under the Independent Inspection Plan, the
producer shall not be permitted to treat material before it has been
properly inspected in the white, as evidenced by the inspector's hammer
mark.
(3) The methods of inspection described in this section and in
Sec. 1728.202 of this part shall be used no matter which plan
crossarms are produced under, i.e., Independent Inspection Plan, or
Quality Assurance Plans, as described in this section.
(e) Quality Assurance Plans. The producer shall furnish crossarms
conforming to this specification as monitored by an acceptable Quality
Assurance Plan. Borrower groups or agents for borrower groups
endeavoring to operate Quality Assurance Plans shall submit their plan
for assuring quality control to the Chairman, Technical Standards
Committee ``A'', Electric Staff Division, USDA Rural Development, Stop
1569, Washington, DC 20250-1569.
(f) Material requirements--(1) Material and grade. All crossarms
furnished under this specification shall be free of brashy wood, decay,
and insect holes larger than \3/32\ of an inch and shall meet
additional requirements as shown on specific drawings. Crossarms shall
be made of one of the following:
(i) Douglas-fir which conforms to the applicable crossarm
provisions of paragraphs 170 and 170a, or the applicable transmission
arm provisions of paragraphs 169 and 169a of the 2004 Standard Grading
Rules for West Coast Lumber No. 17. Only coastal origin Douglas-fir
shall be used for Douglas-fir crossarms manufactured under this
specification;
(ii) Southern Yellow Pine which conforms to the provisions of Dense
Industrial Crossarm 65, as described in paragraph 31.2 in Southern Pine
Inspection Bureau 1991 Special Product Rules for Southern Pine; or
(iii) Laminated wood crossarms shall conform to ANSI O5.2, and have
at least the same load carrying capacity as the solid sawn arm it
replaces. The load carrying capacity of the laminated arms shall be
determined by one of the procedures outlined in ANSI O5.2.
[[Page 56517]]
(2) Borrowers may use alternative crossarms that are listed in
Informational Publication 202-1, List of Materials Acceptable for Use
on Systems of the Agency Electrification Borrowers.
(3) Knots. Sound, firm, and tight knots, if well spaced, are
allowed.
(i) Slightly decayed knots are permitted, except on the top face,
provided the decay extends no more than \3/4\ of an inch into the knot
and provided the cavities will drain water when the arm is installed.
For knots to be considered well spaced, the sum of the sizes of all
knots in any 6 inches of length of a piece shall not exceed twice the
size of the largest knot permitted. More than one knot of maximum
permissible size shall not be in the same 6 inches of length. Slightly
decayed, firm, or sound ``pin knots'' (\3/8\ of an inch or less) are
not considered in size, spacing, or zone considerations.`
(ii) Knots are subject to limits on size and location as detailed
in Tables I and II, as follows:
BILLING CODE 3410-P
[[Page 56518]]
[GRAPHIC] [TIFF OMITTED] TP29SE08.056
BILLING CODE 3410-C
(iii) Knot clusters shall be prohibited unless the entire cluster,
measured on the worst face, is equal to or less than
[[Page 56519]]
the round knot allowed at the specific location.
(iv) Spike knots shall be prohibited in deadend arms. Any spike
knot across the top face shall be limited to the equivalent
displacement of a knot \3/8\ of an inch deep on one face and the
maximum round knot for its particular location on the worst face, with
a maximum width of 1 inch measured at the midpoint of the spiked
section. Elsewhere across the bottom or side faces, spike knots shall
not exceed \1/2\ the equivalent displacement of a round knot permitted
at that location, provided that the depth of the knot on the worst face
shall not exceed the maximum round knot allowed at that location.
(v) Loose knots and knot holes shall be such that they can drain
water when the arm is installed in its normal position. In the center
section, upper half, loose knots shall not be greater than \1/2\ the
dimensions of round knots. Elsewhere, loose knots shall not be greater
than the round knot dimension. Loose knots shall be prohibited in
deadend arms.
(vi) All knots except those ``spike'' knots intersecting a corner
shall be measured on the least diameter of the knot.
(vii) A knot shall be considered to occupy a specific zone or
section if the center of the knot (i.e., pith of knot) is within the
zone or on the zone's boundary.
(viii) If a round or oval knot appears on two faces and is in two
zones, each face shall be judged independently. When this does not
occur, average the least dimension showing on both faces. Knots which
occur on only one face of a free of heart center (FOHC) arm shall be
permitted to be 25 percent larger than the stated size.
(ix) Knot spacing. Two or more knots opposite each other on any
face shall be limited by a sum not to exceed the size of a maximum
single knot permitted for the location. On all four faces, all knots
shall be well spaced.
(x) Knots which have a maximum of \5/8\ inch diameter may intersect
pin holes in the center section. One inch diameter knots may intersect
insulator pin holes elsewhere.
(4) Miscellaneous characteristics, features, and requirements. (i)
The top face of distribution crossarms shall not have more than four
medium pitch and bark pockets in 8-foot arms, and not more than five
pitch and bark pockets in 10-foot arms. Elsewhere a maximum of six
medium pockets in 8-foot arms and eight in 10-foot arms shall be
permitted. Equivalent smaller pockets shall be permissible. An
occasional large pocket is permissible.
(ii) Shakes shall be prohibited.
(iii) Checks. Prior to treatment on properly seasoned arms, single
face checks shall not exceed an average penetration of \1/4\ the depth
from any face and shall be limited to 10 inches long on the top face,
and \1/3\ the arm length on the other faces. Checks shall not be
repeated in the same line of grain in adjacent pin holes. The sum of
the average depths of checks occurring in the same plane on opposite
faces shall be limited to \1/4\ the face depth.
(iv) Compression wood shall be prohibited on any face. Compression
wood is permitted if wholly enclosed in the arm, more than six annual
rings from the surface, and not over \3/8\ of an inch in width.
(v) Insect holes \3/32\ of an inch and larger shall be prohibited.
Insect pin holes (i.e. holes not over \1/16\ of an inch diameter) shall
be allowed if scattered and not exceeding 10 percent of the arm girth.
(vi) Wane shall be allowed on one edge, limited to approximately 1
inch measured across the corner. Outside of the top center section, an
aggregate length not to exceed 2 feet may have wane up to 1\1/2\ inches
on an occasional piece on one or both edges. Bark shall be removed.
(vii) Prior to preservative treatment, and after treatment, crook,
bow, or twist shall not exceed \1/2\ of an inch in 8-foot arms and \5/
8\ of an inch in 10-foot arms.
(g) Manufacture. (1) All dimensions and tolerances shall conform to
those shown on the drawings in this section or drawings supplied with
the purchase order. Drawings supplied shall meet or exceed minimum
dimensions and tolerances shown on the drawings in this section. Cross-
sectional dimensions shall be measured and judged at about \1/4\ the
arm length, except when the defects of ``skip dressing'' or ``machine
bite or offset'' are involved.
(2) Lamination techniques shall comply with ANSI O5.2-1996.
(3) Pin and bolt holes shall be smoothly bored without undue
splintering where drill bits break through the surface. The center of
any hole shall be within \1/8\ of an inch of the center-line locations
on the face in which it appears. Holes shall be perpendicular to the
starting and finishing faces.
(4) Shape. The shape of the arms at any cross section, except for
permissible wane, shall be as shown on the respective drawings in this
section or supplied with the order. The two top edges may be either
chamfered or rounded \3/8\ of an inch radius. The two bottom edges
shall be slightly eased \1/8\ of an inch radius for the entire length.
(5) Incising. The lengthwise surfaces of Douglas-fir crossarms
shall be incised approximately \1/4\ of an inch deep. The incision
shall be reasonably clean cut with a spacing pattern that ensures
uniform penetration of preservative.
(6) Quality of Work. All crossarms shall be of the highest quality
production. Crossarms shall be dressed on four sides, although ``hit
and miss skips'' may occur on two adjacent faces on occasional pieces.
(h) Conditioning prior to treatment. (1) All solid sawn crossarms
shall be made of lumber which has been kiln-dried. Douglas-fir arms
shall have an average moisture content of 19 percent or less, with a
maximum not to exceed 22 percent. Southern Yellow Pine arms shall have
an average moisture content of 22 percent or less, with a maximum not
to exceed 30 percent.
(2) Moisture content levels shall be measured at about \1/4\ the
length and at a depth of about \1/5\ the crossarm's thickness.
Additionally, the moisture content gradient between the shell (i.e. \1/
4\ of an inch deep) and the core (i.e. about 1 inch deep) shall not
exceed 5 percentage points.
(3) A minimum of at least 20 solid sawn crossarms per treating
charge shall be measured to verify moisture content and shall be duly
recorded by the quality control designee.
(4) The moisture content of lumber used in laminating shall, at the
time of gluing, be within the range of 8 to 12 percent, inclusive.
(i) Preservatives. (1) The preservatives shall be:
(i) Creosote which conforms to the requirements of AWPA Standard P1
when analyzed in accordance with the methods in AWPA Standard A1,
sections 2, 3, 4, either 5 or 9, and 6;
(ii) Pentachlorophenol which contains not less than 95 percent
chlorinated phenols and conforms to AWPA Standard P8 when analyzed in
accordance with AWPA Standard A5 or A9. The hydrocarbon solvents for
introducing the preservative into the wood shall meet the requirements
of AWPA Standard P9 Type A;
(iii) Waterborne Preservatives, shall be any of the following:
(A) Ammoniacal Copper Arsenates (ACA) and Ammoniacal Copper Zinc
Arsenate (ACZA) which shall meet the requirements of AWPA Standard P5,
when analyzed in accordance with methods in AWPA Standards A2, A9, or
A11; and
(B) Chromated Copper Arsenates (CCA) which shall meet the
requirements of one of the formulations
[[Page 56520]]
given in AWPA Standard P5, sections 4, 5 or 6, and 10. Tests to
establish conformity shall be made in accordance with AWPA Standards
A2, A9, or A11.
(1) The pH of treating solutions of the waterborne preservatives
shown in AWPA Standard P5, section 10, shall be determined in
accordance with AWPA Standard A2, section 8.
(2) Waterborne preservatives are available either as oxides, which
form non-ionizing chemical compounds in the wood, or as salts, which
leave ionizing compounds as well as non-ionizing compounds in the wood.
Unless otherwise specified in the purchase order, the oxide
formulations of waterborne preservatives shall be supplied.
(3) Douglas-fir crossarms shall not be treated with CCA
preservatives.
(4) Materials treated with waterborne preservatives shall be free
of visible surface deposits.
(iv) Copper Naphthenate (CuN) concentrate used to prepare wood
preserving solutions shall contain not less than 6 percent nor more
than 8 percent copper in the form of CuN and shall conform to AWPA
Standard P8 when analyzed in accordance with AWPA Standard A5. The
hydrocarbon solvents for introducing the preservative into the wood
shall meet the requirements of AWPA Standard P9 Type A.
(2) [Reserved]
(j) Preservative treatment. (1) All timber products treated under
this specification shall be treated by either a pressure or a thermal
(non-pressure) process.
(2) These materials may be further conditioned by steaming, or by
heating in hot oil (Douglas-fir), within the following limits:
------------------------------------------------------------------------
Time hours
(max.) Temperature
------------------------------------------------------------------------
Steam.............................. 3 220[deg] F
Heating in Preservation............ 3 210[deg] F
------------------------------------------------------------------------
(3) A final steam or hot oil bath may be used only to meet
cleanliness requirements of paragraph (k) of this section. Total
duration of the final steam bath shall not exceed 2 hours and the
temperature shall not exceed 240 degrees Fahrenheit.
(k) Results of treatments. (1) The quality control designee shall
test or supervise the testing of each treated charge for penetration
and retention.
(2) Method of Sampling. When testing penetration and retention, a
borer core shall be taken from not less than 20 crossarms in each
treating charge. The borings shall be taken from any face except the
top face at a point as close to the end as possible, being at least 3
inches from the end of the arm and no closer than 3 inches from the
edge of the holes. The bored holes shall be plugged with preservative-
treated plugs driven into the arm. Borings from laminated arms shall
not be taken from the same laminate unless there is an end joint
separation.
(3) As determined in accordance with AWPA A3, all sapwood present
in Douglas-fir or Southern Yellow Pine crossarms shall be completely
penetrated with preservative. In the heartwood of Douglas-fir
crossarms, the penetration shall be not less than 3 inches
longitudinally from the edge of holes and ends, and at least \3/16\
inch from the surface of any face.
(4) Retention of preservative in the outer \6/10\ of an inch for
Douglas-fir and one inch for Southern Yellow Pine assay zones at the
treating plant shall be not less than:
----------------------------------------------------------------------------------------------------------------
Retention
Preservation (pcf) AWPA analysis method
----------------------------------------------------------------------------------------------------------------
Creosote..................................... 8 A6
Pentachlorophenol............................ *0.4 A5
ACA, ACZA, or CCA............................ 0.4 A2, A7, A9, or A11
Copper Naphthenate........................... 0.04 A5, A9, or A11
----------------------------------------------------------------------------------------------------------------
* The pentachlorophenol retention is for the lime ignition method. The copper pyridine method, retention 0.36
pcf is required when timbers may have been in contact with salt water, and for all species native to the
Pacific coast region. It is not required when it specifically states on the rough sawn material invoice that
this material has not been in contact with salt water or is shown by analysis to have no additional chlorides
present in the wood before treating.
(5) Cleanliness of lengthwise surfaces of all crossarms shall be
free from tarry, greasy, or sticky material, and from oil exudation and
pentachlorophenol crystallization (blooming).
(6) Re-treatment of materials which do not meet the penetration and
retention requirements of this specification may be done only twice.
Initial treatment steaming time plus re-treatment steaming time,
combined, shall not exceed time allowed in paragraph (i) of this
section.
(l) Marks and brands. (1) All crossarms shall be legibly branded
(hot brand) or die-stamped and to a depth of approximately \1/16\ of an
inch before treatment.
(2) The letters and figures shall be not less than \1/2\ of an inch
in height. The top of the brand shall be oriented to the top of the
arm.
(3) The brand or die-stamp shall include:
(i) The manufacturer's identification symbol;
(ii) Month and year of manufacture;
(iii) Species of timber such as DF for Douglas-fir and SP for
Southern Yellow Pine; and
(iv) The preservative notated with a C for creosote, P for penta, S
for waterbornes, or N for Copper Naphthenate.
(4) An example is:
M-6-06 Manufacturer--Month--Year
DF-P Douglas-fir--penta treated
(5) The brand or stamp shall be placed on either of the wide
surfaces of the arms, oriented with letters right side up towards the
top of the arm and preferably about 1 foot from the midpoint of the
arm.
(6) The mark should be approximately the same location on each type
of crossarm of each producer.
(7) Brands, inspection marks, or quality assurance marks shall be
removed from arms that do not meet these specifications.
(m) Storage. (1) Producers may treat crossarms for reserve stock
under any of the Rural Development approved plans.
(2) Crossarms treated with oil-borne preservatives which have been
held in storage for more than 1 year before shipment to the borrower,
shall be re-assayed before shipment and shall be re-treated if found
nonconforming for retention on orders placed in accordance with this
section.
(3) Crossarms shall meet the assay after re-treatment in accordance
with paragraph (k) of this section.
(4) Crossarms which are held in storage after final acceptance
shall be stacked in piles or on skids in such a manner as to assure
good ventilation. The stacks shall be covered or stored indoors for
protection from the sun and weather to reduce checking, bending, and
loss of preservative.
[[Page 56521]]
(n) Drawings. (1) The drawings of Appendix B of this section,
Crossarm Drilling Guide, have a type number and show in detail the hole
size, shape, and pattern desired for crossarms ordered under this
specification.
(2) Purchase orders shall indicate the type or size and length
crossarm required. For orders of arms where no drawings are included,
the dimension tolerance of + \1/8\''-0'' shall be used. For example, a
3\3/4\ x 4\3/4\ cross section shall actually be 3\3/4\'' x 4 \3/4\'' +
\1/8\''.
(3) Crossarms shall be furnished in accordance with the details of
these drawings or in accordance with drawings attached to the purchase
order.
(4) Appropriate drawings for transmission arms are to be specified
and included with purchase orders. Technical drawings for transmission
crossarms are published in Bulletin 1728F-811, ``Electric Transmission
Specifications and Drawings, 115kV through 230kV'', and Bulletin 1728F-
810, ``Electric Transmission Specification and Drawings, 34.5kV through
69kV''.
(o) Destination inspection. All crossarms shall meet or exceed
their minimum dimensions for at least 1 year after date of delivery.
Borrowers have the right to reject crossarms that do not meet minimum
dimensions.
BILLING CODE 3410-P
[[Page 56522]]
Appendix A to Sec. 1728.201--Distribution and Transmission Arms
[GRAPHIC] [TIFF OMITTED] TP29SE08.057
[[Page 56523]]
Appendix B to Sec. 1728.201--Crossarm Drilling Guide
[GRAPHIC] [TIFF OMITTED] TP29SE08.058
[[Page 56524]]
BILLING CODE 3410-C
Appendix C to Sec. 1728.201--Metric Conversion Factors
------------------------------------------------------------------------
To convert from To Multiply by
------------------------------------------------------------------------
Foot (ft)......................... Meter (m)........... 0.3048
Inch (in)......................... Centimeter.......... 2.54
Pound per cubic foot (pcf) (lb/ Kilogram per cubic 1.601846
ft\3\). meter (kg/m\3\).
Pound per square inch (psi) (lb/ Kilogram per square 703.0696
in\2\). meter (kg/m\2\).
Degrees Fahrenheit (X [deg]F)..... Degrees Celsius \5/9\(X[deg]-
([deg]C). 32)
------------------------------------------------------------------------
4. Section 1728.202 is amended by revising paragraphs (a) through
(k) and by revising Appendix A to Sec. 1728.202 to read as follows.
Sec. 1728.202 Bulletin 1728H-702, Specification for Quality Control
and Inspection of Timber Products.
(a) Scope. This specification describes in more detail the
responsibilities and procedures pertaining to quality control for
crossarms, as specified in section 1728.201 of this part, and poles,
covered in Bulletin 1728F-700, Specification for Wood Poles, Stubs and
Anchor Logs,'' incorporated by reference in Sec. 1728.97 of this part
and in Sec. 1755.97 of 7 CFR part 1755.
(b) Related specifications and standards incorporated by reference.
The following specifications and standards referenced throughout this
section are pending approval of incorporation by reference in
accordance with 5 U.S.C. 552(a) and 1 CFR part 51. Copies of each are
available for inspection during normal business hours, room 1246-S,
U.S. Department of Agriculture, Washington, DC or at the Office of the
Federal Register, 800 North Capitol Street, NW., suite 700, Washington,
DC. Copies of these standards and specifications may be purchased from
the addresses shown below.
(1) American Wood-Protection Association (AWPA), Book of Standards,
2005 edition, available from AWPA, P.O. Box 361784, Birmingham, AL
35236-1784, telephone 205 733-4077, http://www.awpa.com/, include the
following standards:
(i) A1-06, Standard for Coal Tar Creosote for Land and Fresh Water
Use.
(ii) A2-05, Standard Methods for Analysis of Waterborne
Preservatives and Fire-Retardant Formulations.
(iii) A3-05, Standard Methods for Determining Penetration of
Preservatives and Fire Retardants.
(iv) A5-05, Standard Methods for Analysis of Oil-Borne
Preservatives.
(v) A6-01, Method for the Determination of Water and Oil-Type
Preservatives in Wood.
(vi) A7-04, Wet Ashing Procedure for Preparing Wood for Chemical
Analysis.
(vii) A9-01, Standard Method for Analysis of Treated Wood and
Treating Solutions by X-Ray Emission Spectroscopy.
(viii) A11-93, Analysis of Treated Wood and Treating Solutions by
Atomic Absorption Spectroscopy.
(ix) U1-07, Use Category System: User Specification for Treated
Wood.
(x) T1-07, Use Category System Processing and Treatment Standard.
(xi) M1-07, Standard for the Purchase and Preservation of Forest
Products.
(xii) M2-05, Standard Instructions for the Inspection of
Preservative Treatment of Wood.
(xiii) M3-05, Standard Quality Control Procedures for Wood
Preserving Plants.
(xiv) M4-06, Standard for the Care of Preservative-Treated Wood
Products.
(xv) P1/P13-06, Standard for Coal Tar Creosote for Land and, Fresh
Water and Marine (Coastal Water Use).
(xvi) P5-07, Standards for Water-Borne Preservatives.
(xvii) P8-06, Standards for Oil-Borne Preservatives.
(xviii) P9-03, Standards for Solvents for Organic Preservative
Systems.
(2) American Institute of Timber Construction (AITC) 200-92,
Inspection Manual, 1992 edition, available from AITC, 7012 S. Revere
Parkway, Suite 140, Englewood, Colorado 80110, telephone number (303)
792-9559.
(3) American National Standards Institute (ANSI) O5.2-1996 (R2001),
American National Standard for Wood Products--Structural Glued
Laminated Timber for Utility Structures, available from ANSI, 25 West
43rd Street, New York, New York 10036, telephone (212) 642-4900, Web
address: http://www.ansi.org/.
(4) American Society for Testing and Materials (ASTM) D9-05,
Standard Terminology Relating to Wood, available from ASTM, 100 Barr
Harbor Dr. West, PO Box C700, Conshohocken, PA 19428-2959, telephone
number (610) 832-9585, Web address: http://www.astm.org.
(c) General stipulations. (1) Conformance of poles and crossarms to
agency specifications for the most part is the responsibility of the
producer's management. A member of the producer's staff shall be
designated quality control designee and charged with the responsibility
for the exercise of proper quality control procedures. Failure of a
selected third-party inspection agency to properly perform their
required overview responsibilities may subject said agency to
subsequent liability claims for unsatisfactory or inadequate product
performance.
(2) The requirements in American Wood Protection Association (AWPA)
Standard M3, covering records, adequate laboratory, plant gauges, and
other plant facilities including proper storage, shall be followed.
(3) The methods of inspection described in this section shall be
used no matter which plan timber products are purchased under, i.e.,
Insured Warranty Plan, Independent Inspection Plan, or Quality
Assurance Plans, as described in Sec. 1728.201 of this part or
Bulletin 1728F-700. The number of poles and crossarms actually
inspected by monitors for quality control under a Quality Assurance
Plan or the Insured Warranty Plan may vary from the number of poles and
crossarms inspected under the Independent Inspection Plan. Under the
Independent Inspection Plan, each pole and a sample number of crossarms
shall be inspected.
(4) Under the Independent Inspection Plan, the borrower should
designate in the purchase order which inspection agency it has
selected. This service shall not be subcontracted to another agency.
Unless the borrower contracts for inspection as a separate transaction,
the treating company shall obtain the services of the borrower's
designated inspection agency. For reserve treated stock for purchase
under the Independent Inspection Plan, the treating company shall
obtain the services of an inspection agency.
(5) Individual inspectors in the employ of Independent Inspection
Agencies shall be experienced, competent and employed by only a single
inspection Agency. The inspector shall perform all phases of the
inspection personally and in the proper sequence. The primary
responsibility of the inspector is to determine, for the
[[Page 56525]]
borrower, by careful inspection and verification, that the timber
products, preservative, and treatment meet the requirements of
Bulletins 1728F-700 and 1728H-701 and that the methods, storage
facilities, and production equipment conform to applicable
specifications. For details of the inspector's qualifications see
Appendix A of this section.
(6) Independent inspection agencies and inspectors shall maintain
their impartiality. To do so, inspection agencies, inspectors,
producers and brokers must maintain the greatest degree of separation
and eliminate even the appearance of a conflict of interest. Inspection
agencies shall not receive gratuities from or enter into financial
agreements, other than for inspection services, with suppliers for
which they perform inspection. Inspection agencies shall not provide
gratuities or free services to suppliers. Inspection agencies shall not
offer product warranties on inspected material.
(7) Failure of an individual inspector to follow proper procedures
or failure of an inspection agency to properly supervise inspectors or
follow the appropriate specifications are grounds for debarment of
inspection of agency financed material.
(8) Inspection agencies shall have and maintain liability insurance
in the amount of $500,000 and a surety bond or miscellaneous errors and
omission insurance for consequential damages for not less than
$250,000. Upon request, evidence of compliance to this requirement
shall be forwarded to the agency. The evidence shall be in the form of
a certificate of insurance or a Bond signed by a representative of the
insurance or Surety Bonding company and include a provision that no
change in, or cancellation of, will be made without the prior written
notice to Chairman, Technical Standards Committee ``A'' (Electric).
(9) Inspection agencies shall maintain their own laboratory that is
properly equipped according to AWPA standards, capable of completely
analyzing the respective preservatives treatments, and at a minimum to
run referee methods. This laboratory shall be independent from any
treating plant laboratory. Independent Inspection Agencies may use one
central laboratory.
(10) Laminated materials manufactured for use on borrower systems
shall comply with manufacturing and quality control requirements
specified in ANSI O5.2-1996 (R2001), American National Standard for
Wood Products--Structural Glued Laminated Timber for Utility
Structures. The product shall be marked and certified.
(i) Laminated material shall be inspected in accordance with ANSI
O5.2-1996 (R2001).
(ii) Quality control of material shall be performed to determine
conformance with Sec. 1728.201 of this part and AITC 200-2004,
Inspection Manual.
(d) Quality control and inspection procedures for product
acceptance. It is the responsibility of the plant quality control
designee to perform the following procedures to ensure that a
particular lot of material conforms to the requirements of the
applicable agency specification prior to treatment. After the plant
quality control designee has performed these procedures, a particular
lot of material shall be released to the inspector for verification of
conformance.
(1) Poles can be purchased under any of the three purchase plans.
These plans are Insured Warranty Plan, Independent Inspection Plan, or
a Quality Assurance Plan. Under all of these plans, all poles in a lot
shall be inspected by the plant quality control designee. Under the
Insured Warranty Plan and a Quality Assurance Plan, the number of poles
in a lot actually inspected by a third party inspector may be less than
every pole, depending on the terms of the plans.
(i) Ample space and assistance shall be provided by the treating
plant for handling and turning to ensure that the surfaces of all items
can be adequately inspected.
(ii) Under the Independent Inspection Plan, all poles shall be
inspected by the Independent Inspector for conformance to the
requirements of Bulletin 1728F-700. If a pole is rejected and the cause
of rejection is corrected, the rejected pole may be offered again for
inspection as new material.
(iii) Dimensions, length, and circumference shall be measured by a
standard steel tape to determine that they are in agreement with the
details for class and length in the brand and butt stamp. If it is
obvious by visual comparison with a measured pole that the brand
information is correct, individual poles need not be measured. Pole
circumference dimensions made prior to treatment shall govern
acceptance. Reduction in dimension due to treatment and shipping shall
be not more than 2 percent below the minimum for the pole class.
(iv) If 15 percent of the poles in a lot offered for inspection are
defective, the inspector shall terminate the inspection. Re-examination
of an entire lot by plant quality control shall be required when the
number of rejected poles equals or exceeds 15 percent of the lot
inspected. All defective or nonconforming poles either shall be removed
from the lot or have their brands marked out.
(v) Poles in a lot shall be inspected for decay and all poles shall
be of the same seasoning condition. If the plant quality control
designee suspects that decay has occurred, a slice from both ends shall
be cut for closer examination. If 5 percent of the inspected poles in a
lot shows evidence of decay, the entire lot shall be unconditionally
rejected without further sorting.
(vi) Moisture content, when limited by the purchaser, as stated on
the purchaser's purchase order, shall be measured by calibrated
electronic moisture meter. Calibration of the meter shall include not
only the zero settings for the X and Y readings, but also two
resistance standards for 12 and 22 percent moisture content.
(vii) Material failing to conform for moisture content may be
retested upon request after a recalibration of the instrument. The
results of the second test shall govern disposition of the lot.
(viii) Re-examination for any mechanical damage or deterioration
and for original acceptance shall be conducted on timber products not
treated within 10 days after original inspection.
(2) Crossarms can be purchased only under either of two purchase
plans. These plans are the Independent Inspection Plan or Quality
Assurance Plans. Under the Independent Inspection Plan, crossarms are
to be inspected prior to manufacture, during manufacture, and after
treatment. Under a Quality Assurance Plan, crossarms are monitored
according to the terms of the quality assurance program acceptable to
Rural Development Utilities Programs.
(i) Inspection prior to treatment shall include:
(A) Surface inspection of all ends of all arms. This is usually
done on the stacks of arms prior to manufacture. Particular attention
shall be paid to defects commonly found in the ends, such as
compression wood, red heart and other forms of decay, shakes, splits,
through checks, scantiness, honeycomb, and low density, determined by
rings per inch and percent of summerwood. Whenever the number of
nonconforming arms is found to exceed 0.5 percent of the lot or one
arm, whichever is greater, the entire lot shall be rejected for excess
number of defective ends. After the producer has removed or marked out
the defective material, the arms may be resubmitted for inspection.
(B) Surface inspection of the lengthwise sides performed on a
random representative sample. The
[[Page 56526]]
sample size shall equal 20 percent of a lot size or 200 arms, whichever
is smaller. The inspector shall examine side surfaces as they are
slowly rotated. When necessary, the rotation may be stopped for closer
inspection. Whenever the number of nonconforming arms is found to
exceed 2 percent of the sample size, the entire lot shall be rejected.
After the producer has removed or marked out the defective material,
the arms may be resubmitted for inspection.
(C) Check of moisture content of the random sample by a calibrated
moisture meter.
(D) Check of crossarm dimensions of the random sample measured
after surfacing.
(ii) Inspection during manufacture shall consist of:
(A) Checking bolt and insulator pin holes for squareness and
excessive splintering;
(B) Checking brands for completeness, location, and legibility; and
(C) Checking arms for conformance.
(iii) Under the Independent Inspection Plan, there shall be a final
inspection after treatment for preservative retention and penetration
and for damage.
(3) Structural glued laminated timber shall be tested and inspected
in accordance with AITC 200, Inspection Manual. Grade of lumber shall
be inspected by a qualified grader for specified quality, and so
marked, in accordance with grading rules of the American Lumber
Standards. Adhesives used for all structural arms shall meet
requirements of ANSI O5.2-1996 (R2001) paragraph 5.2. Melamine urea
adhesives shall not be used. End joint spacing and limitations shall be
in accordance with ANSI O5.2-1996 (R2001).
(e) Preservatives. (1) Creosote shall conform to the requirements
of AWPA Standard P1 when analyzed by AWPA Standard Al, sections 2, 3,
4, either 5 or 9, and 6, as follows:.
(i) Each occasional charge; and
(ii) The first charge and one of every five charges randomly
selected in consecutive charges shall be analyzed.
(2) Solutions of waterborne preservatives shall be analyzed for
components in accordance with AWPA Standards A2, A9, or A11, and shall
meet the requirements of P5 for composition. AWPA A2 shall be used as a
referee method.
(3) Pentachlorophenol shall contain not less than 95 percent
chlorinated phenols and should conform to AWPA Standard P8 in
hydrocarbon solvent AWPA P9 Type A.
(4) Copper Naphthenate in hydrocarbon solvent (AWPA P9 Type A)
shall contain not less than 6 percent nor more than 8 percent copper in
the form of Copper Naphthenate and shall conform to AWPA Standard P8
when analyzed in accordance with AWPA Standard A5.
(f) Plant facilities and inspection during treatment. (1)
Manufacturing and treating plant facilities shall conform to AWPA
Standard M3, paragraph 3. Pressure plants shall be equipped with
recording instruments to register time, pressure, temperature and
vacuum during each cycle of treatment. Pressure plants shall also be
equipped with indicating thermometers and pressure and vacuum gauges to
check the accuracy of the recorders. Work tanks shall be equipped with
a thermometer. Thermal treating vats shall be equipped with a time and
temperature recorder and with an indicating thermometer. Temperature
recording devices are not mandatory for plants treating exclusively
with waterborne preservatives.
(2) Temperature and humidity readings throughout the kiln shall be
recorded on a recording chart and verified by observation of direct
reading equipment. Gauges and recording equipment shall be calibrated
annually.
(3) Under the Independent Inspection Plan, the inspector shall be
present during the treatment procedure, except at times when it may be
impractical, such as during late night or early morning treatments. At
such times of absence, temperature, pressure, and vacuum data shall be
taken from the recording charts.
(4) Recording instruments shall be checked with calibrated
indicating gauges and thermometers, per AWPA standard M3. Inaccuracies
shall be referred to the treating plant for prompt correction. If an
inaccuracy which indicates error resulting in non-compliance with this
specification indicating possible damage to the material, the inspector
shall reject the charge.
(g) Results of treatment. (1) Poles shall be tested for retention
and penetration by means of a calibrated increment borer 0.2 inches
0.02 inches in diameter in accordance with procedures in
AWPA Standard M2. Under the Independent Inspection Plan, all treating
charges shall be tested for retention and penetration. Plant quality
control and independent inspection shall do their analyses separately.
Under the Insured Warranty Plan and Quality Assurance Plans, the
frequency of testing retention and penetration may vary according to
the Agency approved plan.
(i) Unless otherwise specified, borings shall be taken
approximately 1 foot above the face brand to 1 foot below the face
brand. For pressure treated Western Red Cedar and all butt treated
poles, borings shall be taken approximately 1 foot below groundline.
(ii) Penetration compliance shall be determined in accordance with
AWPA Standard A3. Chrome Azurol S and Penta-Check shall be used to
determine penetration of copper containing preservatives and penta,
respectively.
(iii) Retention sampling. (A) When there are 20 or more poles in
the treating charge, the retention sample for creosote shall consist of
20 assay zones from southern pine and Douglas-fir poles. All poles in
charges with fewer than 20 poles shall be bored once. Charges with less
than 15 poles shall be bored once and bored again on a random basis to
obtain a minimum of 15 assay zones.
(B) Retention samples shall be taken from 20 poles in charges of 20
or more poles.
(C) Retention samples for Alaska yellow, western red, and northern
white cedars shall consist of a minimum of 30 assay zones for creosote
and waterborne preservatives. For penta charges of fewer than 30 poles,
the sample shall contain the assay zone from each pole in the lot.
(D) Retention samples shall consist of borings, representative of
pole volumes for each class and length in the charge. Further selection
and marking of poles of mixed seasoning, volume, and location on the
tram shall be made as illustrated in the following table:
----------------------------------------------------------------------------------------------------------------
Vol. in cu. % of total Number of
Number of poles Class/length ft. volume borings
----------------------------------------------------------------------------------------------------------------
27.............................................. 7/30 232 15 3
26.............................................. 4/35 447 29 6
11.............................................. 5/35 163 10 2
* 55............................................ 6/35 704 46 9
---------------------------------------------------------------
[[Page 56527]]
Total....................................... .............. 1,546 .............. ..............
----------------------------------------------------------------------------------------------------------------
* If a portion of these poles were green and some partially seasoned, then the number of borings should reflect
the approximate percentage of each.
(iv) When material in a lot consists of fewer pieces than the
designated minimum number of samples for assay, additional borings
shall be taken so as to make up at least the minimum sample, and in
such manner that the sample is representative of the lot of material
with respect to any variations in size, seasoning condition, or other
features that might affect the results of treatment.
(v) Analyses for preservative retention shall be performed as
follows:
(A) Creosote retention shall be analyzed by AWPA Standard A6;
(B) Penta retention shall be analyzed by AWPA Standard A5 or A9.
Copper pyridine method is required when timber may have been in contact
with salt water and for all species native to the Pacific coast region,
unless the raw material invoice specifically states that the material
either has not been in contact with salt water or has been shown by
analysis to have contained no additional chlorides before treating;
(C) Copper Naphthenate retention shall be analyzed by tests in
accordance with AWPA Standards A5 or A9;
(D) Waterborne preservatives retention shall be analyzed by tests
in accordance with AWPA Standards A2, A7, A9, or A11; and
(E) Prior to unloading a tram, the inspectors may take their own
samples and analyze them concurrently with the quality control
designee, but each shall work independently, and quality control data
shall be presented before acceptance of the charge.
(vi) Penetration sampling of poles. (A) Group A poles consist of
poles with a circumference of 37.5 inches or less at 6 feet from butt.
(1) Bore 20 Group A poles or 20 percent of the poles, whichever is
greater. Accept if 100 percent of the sample conform; otherwise, bore
all poles.
(2) Re-treat the charge if more than 15 percent of the borings are
found to be nonconforming.
(3) Re-treat all nonconforming poles if 15 percent or fewer fail
the requirement.
(B) Group B poles consist of poles with circumference greater than
37.5 inches at 6 feet from the butt.
(1) For Group B poles 50 feet and shorter, bore each pole and re-
treat only those found to be nonconforming, unless more than 15 percent
fail; in that case, re-treat the entire lot.
(2) For Group B poles longer than 50 feet, bore each pole twice at
90 degrees apart around the pole and accept only those poles conforming
to the penetration requirement in both borings. All nonconforming poles
may be re-treated only twice.
(vii) All holes (nominal 0.2 of an inch diam. bit) shall be
promptly filled with treated, tight-fitting wood plugs.
(2) Under the Independent Inspection Plan, all treating charges of
crossarms shall be tested for retention and penetration. Plant quality
control inspectors and independent inspectors shall do their analyses
independently. Under the Quality Assurance Plans, the frequency of
testing retention and penetration may vary according to the plan.
(i) The penetration and retention sample shall consist of 20 (48
for creosote) outer \6/10\ of an inch for Douglas-fir and 1 inch for
Southern Yellow Pine zones from borings taken from any face except the
top face at a location as close to the end as possible being at least 3
inches from the end of the arm and no closer than 3 inches from the
edge of any holes. For laminated material, borings shall be taken from
laminates on a random basis.
(ii) Preservative penetration shall be tested by taking not less
than 20 borings from 20 crossarms in each charge, determined in
accordance with AWPA Standard A3. Chrome Azurol S and Penta-Check shall
be used to determine penetration of copper containing preservatives and
penta, respectively.
(3) Laminated material shall be checked for any evidence of
delamination due to treatment and for the identifying quality stamp of
AITC or American Plywood Association (APA).
(4) If used for analysis, x-ray fluorescence instruments (XRF)
shall be accurate and reliable, and they shall generate reproducible
results. Instruments shall have thorough instructions which should
include recommendations on drying techniques, equipment, and density
calculations. These drying recommendations shall be followed when using
XRF instruments.
(5) To check the precision of the x-ray fluorescence instrument
(XRF) at plants where it is used, once weekly the independent inspector
shall rerun a sample at the inspection agency's laboratory. The
independent inspector's laboratory shall use XRF or the referee method,
maintain a log showing the plant's analysis value and the inspector's
laboratory result. If the values are within the AWPA precision
statement for each respective analysis method, the plant instrument
needs no further calibration. Inspection agency XRF instruments shall
be calibrated quarterly by the referee method for each preservative
treatment that is being analyzed by the XRF.
(6) Each independent inspector and plant quality control personnel
that use XRF instruments, shall be trained and certified competent by
the instrument manufacturer.
(h) Product acceptance. Under the Independent Inspection Plan, the
inspector shall signify acceptance by marking each piece of accepted
material with a clear, legible hammer stamp in one end prior to
treatment and in the other end after treatment. The inspector shall
personally mark each piece, and shall not delegate this responsibility
to another person.
(i) Charge Inspection Reports.
(1) Inspection Reports shall have the following matters:
(i) Total pieces in the lot, number of pieces, and causes for
rejection;
(ii) Conditioning details of the material prior to treatment;
(iii) Analyses of preservatives identified by the analyst's
signature or certification;
(iv) The details of treatment; and
(v) The results of treatment. Results shall include the following:
(A) The depth of penetration for retention samples and a summary of
all poles rejected for insufficient penetration;
(B) Separate worksheets for retention analyses, prepared by quality
control designee and independent inspector;
(2) On each inspection report the independent inspector and the
plant quality control designee shall certify, in writing, that the
material listed on the report has been inspected before, during, and
after treatment, and that the preservative used was analyzed in
accordance with the requirements of this section.
(3) Each inspector or inspection agency shall permanently retain
for a period of 1 year a copy or transcript of
[[Page 56528]]
each report of inspection, together with laboratory worksheets covering
retention by assay and preservative analyses for the purchaser, and on
request shall furnish a copy or transcript of any of these reports to
the Chairman, Technical Standards Committee ``A'', Electric Staff
Division, USDA Rural Development Utilities Programs, Washington, DC
20250-1569.
(j) Charge numbers on re-treat poles. The letter ``R'' shall be
added to the original charge number in the butts of all poles that are
re-treated for insufficient penetration or retention of preservative.
All poles that fail to meet treatment requirements after two re-
treatments shall be permanently rejected.
(k) Safety provisions. Poles intended for agency borrowers shall
not be inspected when, in the opinion of the inspector, unsafe
conditions are present.
Appendix A to Sec. 1728.202--Inspector's Qualifications
Inspection agencies should see that inspectors assigned to the
inspection of timber products and treatment for borrowers are
competent and experienced.
In general, any of the following examples are considered as
minimum qualifying experience before a new inspector may be
permitted to inspect timber products for borrowers:
(a) Three years' experience as an inspector of timber and the
preservative treatment of timber; or
(b) Three years' experience in timber treating plant quality
control work; or
(c) Under the direct, on site, supervision of an experienced,
well-qualified inspector, the prospective inspector shall have
performed the following:
(1) Inspected at least 10,000 poles and/or crossarms ``in the
white.''
(2) Checked preservative penetration results on at least 10,000
poles and crossarms;
(3) Made at least 100 wood assays for preservative retention;
(4) Made at lease 25 analyses of each type of preservative used
on material the person is assigned to inspect; and
(5) Certified competent by the XRF instrument manufacturer.
(d) In both (a) and (b) of this Appendix A, the experience
should be not less than that required in (c).
(e) Inspectors experienced in the inspections of one product,
such as poles, should not be qualified to inspect another product,
such as crossarms, until the above experience is gained for each
respective product.
(f) The inspector should be especially well informed in wood
preservation and the operation of a timber treating plant, and be
competent in preservative analysis and other laboratory work.
(g) In all cases, an inspector should be thoroughly instructed
in the application of the specifications and the standards
pertaining thereto before being permitted to independently inspect
timber products and the treatments applied to them. Knowledge of
these specifications and standards, as well as the inspector's
proficiency, may be checked routinely by members of the agency
staff.
* * * * *
PART 1755--TELECOMMUNICATIONS STANDARDS AND SPECIFICATIONS FOR
MATERIALS, EQUIPMENT AND CONSTRUCTION
4. The authority citation continues to read as follows:
Authority: 7 U.S.C. 901 et seq., 1921 et seq., 6941 et seq.
5. Section 1755.97 is amended in the table by revising the entry
for Bulletin 1728F-700 to read as follows:
Sec. 1755.97 Incorporation by reference of telephone standards and
specifications.
* * * * *
----------------------------------------------------------------------------------------------------------------
Specification Title of standard or
Bulletin No. No. Date last issued specification
----------------------------------------------------------------------------------------------------------------
* * * * * * *
1728F-700............................. .............. [Effective date of final Specification for Wood Poles,
rule]. Stubs and Anchor Logs.
----------------------------------------------------------------------------------------------------------------
Dated: September 8, 2008.
James M. Andrew,
Admininstrator, Rural Utilities Service.
[FR Doc. E8-21798 Filed 9-26-08; 8:45 am]
BILLING CODE 3410-15-P