Department of Energy
-----------------------------------------------------------------------
10 CFR Parts 429 and 430
Energy Conservation Program: Certification, Compliance, and Enforcement
for Consumer Products and Commercial and Industrial Equipment; Rule;
Correction
Federal Register / Vol. 76 , No. 84 / Monday, May 2, 2011 / Rules and
Regulations
[[Page 24762]]
-----------------------------------------------------------------------
DEPARTMENT OF ENERGY
10 CFR Parts 429 and 430
[Docket No. EERE-2010-BT-CE-0014]
RIN 1904-AC23
Energy Conservation Program: Certification, Compliance, and
Enforcement for Consumer Products and Commercial and Industrial
Equipment; Correction
AGENCY: Office of Energy Efficiency and Renewable Energy, Department of
Energy.
ACTION: Final rule; technical correction.
-----------------------------------------------------------------------
SUMMARY: This document contains technical corrections to the final rule
regarding certification, compliance, and enforcement regulations that
was published on March 7, 2011. In that final rule, the U.S. Department
of Energy (DOE) adopted regulations that provided for sampling plans
used in determining compliance with existing standards, manufacturer
submission of compliance statements and certification reports to DOE,
maintenance of compliance records by manufacturers, and the
availability of enforcement actions for improper certification or
noncompliance with an applicable standard. Due to drafting error,
language was inadvertently deleted from the rule and certain provisions
contained erroneous internal cross references.
DATES: This correction is effective May 2, 2011. The technical
corrections to Sec. Sec. 429.12 through 429.54 are effective July 5,
2011.
The corrections to Sec. 429.70, Appendix A to Subpart B of Part
429, Appendix C to Subpart C of Part 429, Appendix A1 to Subpart B of
Part 430, and Appendix B1 to Subpart B of Part 430 are effective as of
May 2, 2011.
The corrections to Appendix A to Subpart B of Part 430 and Appendix
B to Subpart B of Part 430 are effective November 28, 2011.
FOR FURTHER INFORMATION CONTACT: Ms. Ashley Armstrong, U.S. Department
of Energy, Office of Energy Efficiency and Renewable Energy, Building
Technologies Program, EE-2J, 1000 Independence Avenue, SW., Washington,
DC 20585-0121. Telephone: 202-586-6590. E-mail:
[email protected]; and Ms. Laura Barhydt, U.S. Department of
Energy, Office of the General Counsel, Forrestal Building, GC-32, 1000
Independence Avenue, SW., Washington, DC 20585. Telephone: 202-287-
6122. E-mail: [email protected].
SUPPLEMENTARY INFORMATION:
I. Background
On March 7, 2011, the U.S. Department of Energy's (DOE) Office of
Energy Efficiency and Renewable Energy (EERE) published a final rule
titled '' Energy Conservation Program: Certification, Compliance, and
Enforcement for Consumer Products and Commercial and Industrial
Equipment.'' 76 FR 12421. Since the publication of that rule, it has
come to DOE's attention that, due to a technical oversight, certain
parts of the final regulation were inadvertently deleted by the rule.
Additionally, several sections of the regulatory text have internal
referencing errors.
II. Need for Correction
In FR Doc. 2011-3146, beginning on page 12421 in the Federal
Register of Monday, March 7, 2011, the following corrections are made:
PART 429--[CORRECTED]
Sec. 429.12 [Corrected]
0
1. On page 12453, in the second column, correct Sec. 429.12, General
requirements applicable to certification reports, paragraph (a), to
read as follows:
(a) Certification. Each manufacturer, before distributing in
commerce any basic model of a covered product or covered equipment
subject to an applicable energy conservation standard set forth in
parts 430 or 431, and annually thereafter on or before the dates
provided in paragraph (d) of this section, shall submit a certification
report to DOE certifying that each basic model meets the applicable
energy conservation standard(s). The certification report(s) must be
submitted to DOE in accordance with the submission procedures of
paragraph (h) of this section.
* * * * *
Sec. 429.14 [Corrected]
0
2. On page 12455, correct the references to ``Appendix D'' to
``Appendix A'' in paragraphs (a)(2)(i)(B) and (a)(2)(ii)(B) to read as
follows:
Sec. 429.14 Residential refrigerators, refrigerator-freezers and
freezers.
(a) * * *
(2) * * *
(i) * * *
(B) The upper 95 percent confidence limit (UCL) of the true mean
divided by 1.10, where:
[GRAPHIC] [TIFF OMITTED] TR02MY11.026
and
(ii) * * *
(B) The lower 95 percent confidence limit (LCL) of the true mean
divided by 0.90, where:
[[Page 24763]]
[GRAPHIC] [TIFF OMITTED] TR02MY11.027
* * * * *
Sec. 429.15 [Corrected]
0
3. On page 12456, correct the references to ``Appendix D'' to
``Appendix A'' in paragraphs (a)(2)(i)(B) and (a)(2)(ii)(B) to read as
follows:
Sec. 429.15 Room air conditioners.
(a) * * *
(2) * * *
(i) * * *
(B) The upper 97\1/2\ percent confidence limit (UCL) of the true
mean divided by 1.05, where:
[GRAPHIC] [TIFF OMITTED] TR02MY11.028
and
(ii) * * *
(B) The lower 97\1/2\ percent confidence limit (LCL) of the true
mean divided by 0.95, where:
[GRAPHIC] [TIFF OMITTED] TR02MY11.029
* * * * *
Sec. 429.16 [Corrected]
0
4. On page 12457, correct the reference to ``Appendix D'' to ``Appendix
A'' in paragraph (a)(2)(i)(A)(2), and on page 12458, correct the
reference to ``Appendix D'' to ``Appendix A'' in paragraph
(a)(2)(i)(B)(2) to read as follows:
Sec. 429.16 Central air conditioners and heat pumps.
(a) * * *
(2)(i) * * *
(A) * * *
(2) The upper 90 percent confidence limit (UCL) of the true mean
divided by 1.05, where:
[GRAPHIC] [TIFF OMITTED] TR02MY11.030
[[Page 24764]]
and
(B) * * *
(2) The lower 90 percent confidence limit (LCL) of the true mean
divided by 0.95, where:
[GRAPHIC] [TIFF OMITTED] TR02MY11.031
* * * * *
Sec. 429.17 [Corrected]
0
5. On page 12459, correct the references to ``Appendix D'' to
``Appendix A'' in paragraphs (a)(2)(i)(B) and (a)(2)(ii)(B) to read as
follows:
Sec. 429.17 Residential water heaters.
(a) * * *
(2) * * *
(i) * * *
(B) The upper 95 percent confidence limit (UCL) of the true mean
divided by 1.10, where:
[GRAPHIC] [TIFF OMITTED] TR02MY11.032
and
(ii) * * *
(B) The lower 95 percent confidence limit (LCL) of the true mean
divided by 0.90, where:
[GRAPHIC] [TIFF OMITTED] TR02MY11.033
* * * * *
Sec. 429.18 [Corrected]
0
6.a. On page 12460, correct the reference to ``Appendix D'' to
``Appendix A'' in paragraph (a)(2)(i)(B)(2);
0
b. On page 12461, correct the references to ``Appendix D'' to
``Appendix A'' in paragraphs (a)(2)(ii)(A)(2) and (a)(2)(ii)(B)(2);
0
c. On page 12462, correct the references to ``Appendix D'' to
``Appendix A'' in paragraphs (a)(2)(iii)(A)(2) and (a)(2)(iii)(B)(2);
and
0
d. On page 12463, correct the references to ``Appendix D'' to
``Appendix A'' in paragraphs (a)(2)(iv)(B)(1)(ii) and
(a)(2)(iv)(B)(2)(ii).
The corrections read as follows:
Sec. 429.18 Residential furnaces.
(a) * * *
(2)(i) * * *
(B) * * *
(2) The lower 97\1/2\ percent confidence limit (LCL) of the true
mean divided by 0.95, where:
[[Page 24765]]
[GRAPHIC] [TIFF OMITTED] TR02MY11.034
(ii) * * *
(A) * * *
(2) The upper 97\1/2\ percent confidence limit (UCL) of the true
mean divided by 1.05, where:
[GRAPHIC] [TIFF OMITTED] TR02MY11.035
and
(B) * * *
(2) The lower 97\1/2\ percent confidence limit (LCL) of the true
mean divided by 0.95, where:
[GRAPHIC] [TIFF OMITTED] TR02MY11.036
(iii) * * *
(A) * * *
(2) The upper 97\1/2\ percent confidence limit (UCL) of the true
mean divided by 1.05, where:
[GRAPHIC] [TIFF OMITTED] TR02MY11.037
and
(B) * * *
(2) The lower 97\1/2\ percent confidence limit (LCL) of the true
mean divided by 0.95, where:
[[Page 24766]]
[GRAPHIC] [TIFF OMITTED] TR02MY11.038
(iv) * * *
(B) * * *
(1) * * *
(ii) The upper 97\1/2\ percent confidence limit (UCL) of the true
mean divided by 1.05, where:
[GRAPHIC] [TIFF OMITTED] TR02MY11.039
and
(2) * * *
(ii) The lower 97\1/2\ percent confidence limit (LCL) of the true
mean divided by 0.95, where:
[GRAPHIC] [TIFF OMITTED] TR02MY11.040
* * * * *
Sec. 429.19 [Corrected]
0
7. On page 12464, correct the reference to ``Appendix D'' to ``Appendix
A'' in paragraph (a)(2)(i)(B), and on page 12465, correct the reference
to ``Appendix D'' to ``Appendix A'' in paragraph (a)(2)(ii)(B) to read
as follows:
Sec. 429.19 Dishwashers.
(a) * * *
(2) * * *
(i) * * *
(B) The upper 97\1/2\ percent confidence limit (UCL) of the true
mean divided by 1.05, where:
[GRAPHIC] [TIFF OMITTED] TR02MY11.041
[[Page 24767]]
and
(ii) * * *
(B) The lower 97\1/2\ percent confidence limit (LCL) of the true
mean divided by 0.95, where:
[GRAPHIC] [TIFF OMITTED] TR02MY11.042
* * * * *
Sec. 429.20 [Corrected]
0
8. On page 12465, correct the reference to ``Appendix D'' to ``Appendix
A'' in paragraph (a)(2)(i)(B), and on page 12466, correct the reference
to ``Appendix D'' to ``Appendix A'' in paragraph (a)(2)(ii)(B) to read
as follows:
Sec. 429.20 Residential clothes washers.
(a) * * *
(2) * * *
(i) * * *
(B) The upper 97\1/2\ percent confidence limit (UCL) of the true
mean divided by 1.05, where:
[GRAPHIC] [TIFF OMITTED] TR02MY11.043
and
(ii) * * *
(B) The lower 97\1/2\ percent confidence limit (LCL) of the true
mean divided by 0.95, where:
[GRAPHIC] [TIFF OMITTED] TR02MY11.044
* * * * *
Sec. 429.21 [Corrected]
0
9. On page 12466, correct the reference to ``Appendix D'' to ``Appendix
A'' in paragraph (a)(2)(i)(B), and on page 12467, correct the reference
to ``Appendix D'' to ``Appendix A'' in paragraph (a)(2)(ii)(B) to read
as follows:
Sec. 429.21 Residential clothes dryers.
(a) * * *
(2) * * *
(i) * * *
(B) The upper 97\1/2\ percent confidence limit (UCL) of the true
mean divided by 1.05, where:
[[Page 24768]]
[GRAPHIC] [TIFF OMITTED] TR02MY11.045
and
(ii) * * *
(B) The lower 97\1/2\ percent confidence limit (LCL) of the true
mean divided by 0.95, where:
[GRAPHIC] [TIFF OMITTED] TR02MY11.046
* * * * *
Sec. 429.22 [Corrected]
0
10. On page 12467, correct the reference to ``Appendix D'' to
``Appendix A'' in paragraph (a)(2)(i)(A)(2), and on page 12468, correct
the reference to ``Appendix D'' to ``Appendix A'' in paragraph
(a)(2)(i)(B)(2) to read as follows:
Sec. 429.22 Direct heating equipment.
(a) * * *
(2)(i) * * *
(A) * * *
(2) The upper 97\1/2\ percent confidence limit (UCL) of the true
mean divided by 1.05, where:
[GRAPHIC] [TIFF OMITTED] TR02MY11.047
and
(B) * * *
(2) The lower 97\1/2\ percent confidence limit (LCL) of the true
mean divided by 0.95, where:
[GRAPHIC] [TIFF OMITTED] TR02MY11.048
[[Page 24769]]
* * * * *
Sec. 429.23 [Corrected]
0
11. On page 12468, correct the reference to ``Appendix D'' to
``Appendix A'' in paragraph (a)(2)(i)(B), and on page 12469, correct
the reference to ``Appendix D'' to ``Appendix A'' in paragraph
(a)(2)(ii)(B) to read as follows:
Sec. 429.23 Conventional cooking tops, conventional ovens, microwave
ovens.
(a) * * *
(2) * * *
(i) * * *
(B) The upper 97\1/2\ percent confidence limit (UCL) of the true
mean divided by 1.05, where:
[GRAPHIC] [TIFF OMITTED] TR02MY11.049
and
(ii) * * *
(B) The lower 97\1/2\ percent confidence limit (LCL) of the true
mean divided by 0.95, where:
[GRAPHIC] [TIFF OMITTED] TR02MY11.050
* * * * *
Sec. 429.24 [Corrected]
0
12. On page 12469, correct the reference to ``Appendix D'' to
``Appendix A'' in paragraph (a)(2)(ii) to read as follows:
Sec. 429.24 Pool heaters.
(a) * * *
(2) * * *
(ii) The lower 97\1/2\ percent confidence limit (LCL) of the true
mean divided by 0.95, where:
[GRAPHIC] [TIFF OMITTED] TR02MY11.051
* * * * *
Sec. 429.26 [Corrected]
0
13. On page 12470, correct the references to ``Appendix D'' to
``Appendix A'' in paragraphs (a)(2)(i)(B) and (a)(2)(ii)(B) to read as
follows:
Sec. 429.26 Fluorescent lamp ballasts.
(a) * * *
(2) * * *
(i) * * *
(B) The upper 99 percent confidence limit (UCL) of the true mean
divided by 1.01, where:
[[Page 24770]]
[GRAPHIC] [TIFF OMITTED] TR02MY11.052
and
(ii) * * *
(B) The lower 99 percent confidence limit (LCL) of the true mean
divided by 0.99, where:
[GRAPHIC] [TIFF OMITTED] TR02MY11.053
* * * * *
Sec. 429.27 [Corrected]
0
14. On page 12471, correct the references to ``Appendix D'' to
``Appendix A'' in paragraphs (a)(2)(i)(B) and (a)(2)(ii)(B) to read as
follows:
Sec. 429.27 General service fluorescent lamps, general service
incandescent lamps, and incandescent reflector lamps.
(a) * * *
(2)(i) * * *
(B) The lower 95 percent confidence limit (LCL) of the true mean
divided by .97, where:
[GRAPHIC] [TIFF OMITTED] TR02MY11.054
(ii) * * *
(B) The lower 95 percent confidence limit (LCL) of the true mean
divided by .97, where:
[GRAPHIC] [TIFF OMITTED] TR02MY11.055
[[Page 24771]]
* * * * *
Sec. 429.28 [Corrected]
0
15. On page 12472, correct the reference to ``Appendix D'' to
``Appendix A'' in paragraph (a)(2)(ii) to read as follows:
Sec. 429.28 Faucets.
(a) * * *
(2) * * *
(ii) The upper 95 percent confidence limit (UCL) of the true mean
divided by 1.05, where:
[GRAPHIC] [TIFF OMITTED] TR02MY11.056
* * * * *
Sec. 429.29 [Corrected]
0
16. On page 12473, correct the reference to ``Appendix D'' to
``Appendix A'' in paragraph (a)(2)(ii), and add at the end of the last
sentence in paragraph (b)(3) ``, 7.4.4(a)''.
The correction reads as follows:
Sec. 429.29 Showerheads.
(a) * * *
(2) * * *
(ii) The upper 95 percent confidence limit (UCL) of the true mean
divided by 1.05, where:
[GRAPHIC] [TIFF OMITTED] TR02MY11.057
* * * * *
(b) * * *
(3) Pursuant to Sec. 429.12(b)(13), a certification report shall
include the following additional product-specific information: A
declaration that the showerhead meets the requirements of ASME/ANSI
A112.18.1M-1996, 7.4.4(a).
Sec. 429.30 [Corrected]
0
17. On page 12473, correct the reference to ``Appendix D'' to
``Appendix A'' in paragraph (a)(2)(ii) to read as follows:
Sec. 429.30 Water closets.
(a) * * *
(2) * * *
(ii) The upper 90 percent confidence limit (UCL) of the true mean
divided by 1.1, where:
[GRAPHIC] [TIFF OMITTED] TR02MY11.058
* * * * *
Sec. 429.31 [Corrected]
0
18. On page 12474, correct the reference to ``Appendix D'' to
``Appendix A'' in paragraph (a)(2)(ii) to read as follows:
Sec. 429.31 Urinals.
(a) * * *
(2) * * *
(ii) The upper 90 percent confidence limit (UCL) of the true mean
divided by 1.1, where:
[[Page 24772]]
[GRAPHIC] [TIFF OMITTED] TR02MY11.059
* * * * *
Sec. 429.33 [Corrected]
0
19. On page 12474, correct the reference to ``Appendix D'' to
``Appendix A'' in paragraph (a)(2)(i)(B), and on page 12475, correct
the reference to ``Appendix D'' to ``Appendix A'' in paragraph
(a)(2)(ii)(B) to read as follows:
Sec. 429.33 Ceiling fan light kits.
(a) * * *
(2) * * *
(i) * * *
(B) The upper 95 percent confidence limit (UCL) of the true mean
divided by 1.1, where:
[GRAPHIC] [TIFF OMITTED] TR02MY11.060
and
(ii) * * *
(B) The lower 95 percent confidence limit (LCL) of the true mean
divided by 0.9, where:
[GRAPHIC] [TIFF OMITTED] TR02MY11.061
* * * * *
Sec. 429.35 [Corrected]
0
20. On page 12476, correct the reference to ``Appendix D'' to
``Appendix A'' in paragraph (a)(2)(i)(B) to read as follows:
Sec. 429.35 Bare or covered (no reflector) medium base compact
fluorescent lamps.
(a) * * *
(2) * * *
(i) * * *
(B) The lower 97.5 percent confidence limit (LCL) of the true mean
divided by 0.95, where:
[GRAPHIC] [TIFF OMITTED] TR02MY11.062
[[Page 24773]]
* * * * *
Sec. 429.36 [Corrected]
0
21. On page 12476, correct the reference to ``Appendix D'' to
``Appendix A'' in paragraph (a)(2)(i)(B), and on page 12477, correct
the reference to ``Appendix D'' to ``Appendix A'' in paragraph
(a)(2)(ii)(B) to read as follows:
Sec. 429.36 Dehumidifiers.
(a) * * *
(2) * * *
(i) * * *
(B) The upper 95 percent confidence limit (UCL) of the true mean
divided by 1.10, where:
[GRAPHIC] [TIFF OMITTED] TR02MY11.063
and
(ii) * * *
(B) The lower 95 percent confidence limit (LCL) of the true mean
divided by 0.90, where:
[GRAPHIC] [TIFF OMITTED] TR02MY11.064
* * * * *
Sec. 429.37 [Corrected]
0
22. On page 12477, correct the reference to ``Appendix D'' to
``Appendix A'' in paragraph (a)(2)(i)(B), and on page 12478, correct
the reference to ``Appendix D'' to ``Appendix A'' in paragraph
(a)(2)(ii)(B) to read as follows:
Sec. 429.37 Class A external power supplies.
(a) * * *
(2) * * *
(i) * * *
(B) The upper 97.5 percent confidence limit (UCL) of the true mean
divided by 1.05, where:
[GRAPHIC] [TIFF OMITTED] TR02MY11.065
and
(ii) * * *
(B) The lower 97.5 percent confidence limit (LCL) of the true mean
divided by 0.95, where:
[[Page 24774]]
[GRAPHIC] [TIFF OMITTED] TR02MY11.066
* * * * *
Sec. 429.39 [Corrected]
0
23. On page 12479, correct the references to ``Appendix D'' to
``Appendix A'' in paragraphs (a)(2)(i)(B) and (a)(2)(ii)(B) to read as
follows:
Sec. 429.39 Battery chargers.
(a) * * *
(2) * * *
(i) * * *
(B) The upper 97.5 percent confidence limit (UCL) of the true mean
divided by 1.05, where:
[GRAPHIC] [TIFF OMITTED] TR02MY11.067
and
(ii) * * *
(B) The lower 97.5 percent confidence limit (LCL) of the true mean
divided by 0.95, where:
[GRAPHIC] [TIFF OMITTED] TR02MY11.068
* * * * *
Sec. 429.40 [Corrected]
0
24. On page 12480, correct the reference to ``Appendix D'' to
``Appendix A'' in paragraph (a)(2)(ii) to read as follows:
Sec. 429.40 Candelabra base incandescent lamps and intermediate base
incandescent lamps.
(a) * * *
(2) * * *
(ii) The lower 97.5 percent confidence limit (LCL) of the true mean
divided by 0.95, where:
[GRAPHIC] [TIFF OMITTED] TR02MY11.069
[[Page 24775]]
* * * * *
Sec. 429.42 [Corrected]
0
25. On page 12480, correct the reference to ``Appendix D'' to
``Appendix A'' in paragraph (a)(2)(i)(B), and on page 12481, correct
the reference to ``Appendix D'' to ``Appendix A'' in paragraph
(a)(2)(ii)(B) to read as follows:
Sec. 429.42 Commercial refrigerators, freezers, and refrigerator-
freezers.
(a) * * *
(2) * * *
(i) * * *
(B) The upper 95 percent confidence limit (UCL) of the true mean
divided by 1.10, where:
[GRAPHIC] [TIFF OMITTED] TR02MY11.070
and
(ii) * * *
(B) The lower 95 percent confidence limit (LCL) of the true mean
divided by 0.90, where:
[GRAPHIC] [TIFF OMITTED] TR02MY11.071
* * * * *
Sec. 429.43 [Corrected]
0
26. On page 12482, correct the references to ``Appendix D'' to
``Appendix A'' in paragraphs (a)(2)(i)(B) and (a)(2)(ii)(B) to read as
follows:
Sec. 429.43 Commercial heating, ventilating, air conditioning (HVAC)
equipment.
(a) * * *
(2) * * *
(i) * * *
(B) The upper 95 percent confidence limit (UCL) of the true mean
divided by 1.05, where:
[GRAPHIC] [TIFF OMITTED] TR02MY11.072
and
(ii) * * *
(B) The lower 95 percent confidence limit (LCL) of the true mean
divided by 0.95, where:
[[Page 24776]]
[GRAPHIC] [TIFF OMITTED] TR02MY11.073
* * * * *
Sec. 429.44 [Corrected]
0
27. On page 12483, correct the reference to ``Appendix D'' to
``Appendix A'' in paragraph (a)(2)(i)(B), and on page 12484, correct
the reference to ``Appendix D'' to ``Appendix A'' in paragraph
(a)(2)(ii)(B) to read as follows:
Sec. 429.44 Commercial water heating equipment.
(a) * * *
(2) * * *
(i) * * *
(B) The upper 95 percent confidence limit (UCL) of the true mean
divided by 1.05, where:
[GRAPHIC] [TIFF OMITTED] TR02MY11.074
and
(ii) * * *
(B) The lower 95 percent confidence limit (LCL) of the true mean
divided by 0.95, where:
[GRAPHIC] [TIFF OMITTED] TR02MY11.075
* * * * *
Sec. 429.45 [Corrected]
0
28. On page 12484, correct the reference to ``Appendix D'' to
``Appendix A'' in paragraph (a)(2)(i)(B), and on page 12485, correct
the reference to ``Appendix D'' to ``Appendix A'' in paragraph
(a)(2)(ii)(B) to read as follows:
Sec. 429.45 Automatic commercial ice makers.
(a) * * *
(2) * * *
(i) * * *
(B) The upper 95 percent confidence limit (UCL) of the true mean
divided by 1.10, where:
[[Page 24777]]
[GRAPHIC] [TIFF OMITTED] TR02MY11.076
and
(ii) * * *
(B) The lower 95 percent confidence limit (LCL) of the true mean
divided by 0.90, where:
[GRAPHIC] [TIFF OMITTED] TR02MY11.077
* * * * *
Sec. 429.46 [Corrected]
0
29. On page 12485, correct the reference to ``Appendix D'' to
``Appendix A'' in paragraph (a)(2)(i)(B), and on page 12486, correct
the reference to ``Appendix D'' to ``Appendix A'' in paragraph
(a)(2)(ii)(B) to read as follows:
Sec. 429.46 Commercial clothes washers.
(a) * * *
(2) * * *
(i) * * *
(B) The upper 97\1/2\ percent confidence limit (UCL) of the true
mean divided by 1.05, where:
[GRAPHIC] [TIFF OMITTED] TR02MY11.078
and
(ii) * * *
(B) The lower 97\1/2\ percent confidence limit (LCL) of the true
mean divided by 0.95, where:
[GRAPHIC] [TIFF OMITTED] TR02MY11.079
[[Page 24778]]
* * * * *
Sec. 429.48 [Corrected]
0
30. On page 12487, correct the references to ``Appendix D'' to
``Appendix A'' in paragraphs (a)(2)(i)(B) and (a)(2)(ii)(B) to read as
follows:
Sec. 429.48 Illuminated exit signs.
(a) * * *
(2) * * *
(i) * * *
(B) The upper 95 percent confidence limit (UCL) of the true mean
divided by 1.10, where
[GRAPHIC] [TIFF OMITTED] TR02MY11.080
and
(ii) * * *
(B) The lower 95 percent confidence limit (LCL) of the true mean
divided by 0.90, where
[GRAPHIC] [TIFF OMITTED] TR02MY11.081
* * * * *
Sec. 429.49 [Corrected]
0
31. On page 12488, correct the references to ``Appendix D'' to
``Appendix A'' in paragraphs (a)(2)(i)(B) and (a)(2)(ii)(B) to read as
follows:
Sec. 429.49 Traffic signal modules and pedestrian modules.
(a) * * *
(2) * * *
(i) * * *
(B) The upper 95 percent confidence limit (UCL) of the true mean
divided by 1.10, where:
[GRAPHIC] [TIFF OMITTED] TR02MY11.082
and
(ii) * * *
(B) The lower 95 percent confidence limit (LCL) of the true mean
divided by 0.90, where:
[[Page 24779]]
[GRAPHIC] [TIFF OMITTED] TR02MY11.083
* * * * *
Sec. 429.51 [Corrected]
0
32. On page 12489, correct the references to ``Appendix D'' to
``Appendix A'' in paragraphs (a)(2)(i)(B) and (a)(2)(ii)(B) to read as
follows:
Sec. 429.51 Commercial pre-rinse spray valves.
(a) * * *
(2) * * *
(i) * * *
(B) The upper 95 percent confidence limit (UCL) of the true mean
divided by 1.10, where:
[GRAPHIC] [TIFF OMITTED] TR02MY11.084
and
(ii) * * *
(B) The lower 95 percent confidence limit (LCL) of the true mean
divided by 0.90, where:
[GRAPHIC] [TIFF OMITTED] TR02MY11.085
* * * * *
Sec. 429.52 [Corrected]
0
33. On page 12490, correct the references to ``Appendix D'' to
``Appendix A'' in paragraphs (a)(2)(i)(B) and (a)(2)(ii)(B) to read as
follows:
Sec. 429.52 Refrigerated bottled or canned beverage vending machines.
(a) * * *
(2) * * *
(i) * * *
(B) The upper 95 percent confidence limit (UCL) of the true mean
divided by 1.10, where:
[GRAPHIC] [TIFF OMITTED] TR02MY11.086
[[Page 24780]]
and
(ii) * * *
(B) The lower 95 percent confidence limit (LCL) of the true mean
divided by 0.90, where:
[GRAPHIC] [TIFF OMITTED] TR02MY11.087
* * * * *
Sec. 429.54 [Corrected]
0
34. On page 12491, correct the reference to ``Appendix D'' to
``Appendix A'' in paragraph (a)(2)(i)(B) to read as follows:
Sec. 429.54 Metal halide lamp ballasts and fixtures.
(a) * * *
(2) * * *
(i) * * *
(B) The lower 99-percent confidence limit (LCL) of the true mean
divided by 0.99.
[GRAPHIC] [TIFF OMITTED] TR02MY11.088
* * * * *
APPENDIX A--[Corrected]
0
35. On page 12494, correct the reference to ``Appendix D'' to
``Appendix A'' in Figure 1 to read as follows:
APPENDIX A TO SUBPART B OF PART 429--STUDENT'S t-DISTRIBUTION VALUES
FOR CERTIFICATION TESTING
Figure 1--t-Distribution Values for Certification Testing
[One-sided]
----------------------------------------------------------------------------------------------------------------
Confidence interval
Degrees of freedom (from Appendix A) -------------------------------------------------------------
90% 95% 97.5% 99%
----------------------------------------------------------------------------------------------------------------
1................................................. 3.078 6.314 12.71 31.82
2................................................. 1.886 2.920 4.303 6.965
3................................................. 1.638 2.353 3.182 4.541
4................................................. 1.533 2.132 2.776 3.747
5................................................. 1.476 2.015 2.571 3.365
6................................................. 1.440 1.943 2.447 3.143
7................................................. 1.415 1.895 2.365 2.998
8................................................. 1.397 1.860 2.306 2.896
9................................................. 1.383 1.833 2.262 2.821
10................................................ 1.372 1.812 2.228 2.764
11................................................ 1.363 1.796 2.201 2.718
12................................................ 1.356 1.782 2.179 2.681
13................................................ 1.350 1.771 2.160 2.650
14................................................ 1.345 1.761 2.145 2.624
15................................................ 1.341 1.753 2.131 2.602
16................................................ 1.337 1.746 2.120 2.583
17................................................ 1.333 1.740 2.110 2.567
18................................................ 1.330 1.734 2.101 2.552
19................................................ 1.328 1.729 2.093 2.539
20................................................ 1.325 1.725 2.086 2.528
----------------------------------------------------------------------------------------------------------------
[[Page 24781]]
APPENDIX C--[Corrected]
0
36. On page 12501, in the first column, correct the reference to
``Appendix D'' to ``Appendix A'' in paragraph (b)(5) to read as
follows:
APPENDIX C TO SUBPART C OF PART 429--SAMPLING PLAN FOR ENFORCEMENT
TESTING OF DISTRIBUTION TRANSFORMERS
* * * * *
(b) * * *
(5) Compute the lower control limit (LCL1) for the
mean of the first sample as follows:
[GRAPHIC] [TIFF OMITTED] TR02MY11.089
* * * * *
0
37. On page 12502, second column, correct amendatory instruction 6 to
read as follows:
6. ``In Appendix A to subpart B of part 430, revise paragraph 5.1,
introductory text, to read as follows:''.
0
38. On page 12502, third column, correct amendatory instruction 8 to
read as follows:
8. ``In Appendix B to subpart B of part 430, revise paragraph 5.1,
introductory text, to read as follows:''.
List of Subjects
10 CFR Part 429
Confidential business information, Energy conservation, Household
appliances, Imports, Reporting and recordkeeping requirements.
10 CFR Part 430
Administrative practice and procedure, Confidential business
information, Energy conservation, Household appliances, Imports,
Intergovernmental relations, Small businesses.
Accordingly, 10 CFR parts 429 and 430, are corrected by making the
following correcting amendments:
PART 429--CERTIFICATION, COMPLIANCE, AND ENFORCEMENT FOR CONSUMER
PRODUCTS AND COMMERCIAL AND INDUSTRIAL EQUIPMENT
0
1. The authority citation for Part 429 continues to read as follows:
Authority: 42 U.S.C. 6291-6317.
Sec. 429.70 [Corrected]
0
2. Section 429.70 is amended:
0
a. In paragraph (d)(2)(ii) by correcting the reference to ``Sec.
429.42'' to read ``Sec. 429.47''; and
0
b. In paragraphs (d)(2)(iii) and (d)(2)(iv) by correcting the
references to ``(c)(2)(i)'' to read ``(d)(2)(i)'', and by correcting
the references to ``(c)(2)(ii)'' to read ``(d)(2)(ii)''.
PART 430--ENERGY CONSERVATION PROGRAM FOR CONSUMER PRODUCTS
0
3. The authority citation for Part 430 continues to read as follows:
Authority: 42 U.S.C. 6291-6309; 28 U.S.C. 2461 note.
Appendix A1 [Corrected]
0
4. In Appendix A1 to subpart B of part 430, revise introductory
paragraph 5.1 to read as follows:
Appendix A1 to Subpart B of Part 430--Uniform Test Method for Measuring
the Energy Consumption of Electric Refrigerators and Electric
Regrigerator-Freezers
* * * * *
5. Test Measurements
5.1 Temperature Measurements. Temperature measurements shall be
made at the locations prescribed in Figures 7.1 and 7.2 of HRF-1-
1979 (incorporated by reference; see Sec. 430.3) and shall be
accurate to within 0.5 [deg]F (0.3 [deg]C). No freezer
temperature measurements need be taken in an all-refrigerator model.
If the interior arrangements of the cabinet do not conform with
those shown in Figure 7.1 and 7.2 of HRF-1-1979, the product may be
tested by relocating the temperature sensors from the locations
specified in the figures to avoid interference with hardware or
components within the cabinet, in which case the specific locations
used for the temperature sensors shall be noted in the test data
records maintained by the manufacturer in accordance with 10 CFR
429.14, and the certification report shall indicate that non-
standard sensor locations were used.
5.1.1 Measured Temperature. The measured temperature of a
compartment is to be the average of all sensor temperature readings
taken in that compartment at a particular time. Measurements shall
be taken at regular intervals not to exceed four minutes.
5.1.2 Compartment Temperature. The compartment temperature for
each test period shall be an average of the measured temperatures
taken in a compartment during one or more complete compressor
cycles. One compressor cycle is one complete motor ``on'' and one
complete motor ``off'' period. For long-time automatic defrost
models, compartment temperatures shall be those measured in the
first part of the test period specified in section 4.2.1. For models
with variable defrost controls, compartment temperatures shall be
those measured in the first part of the test period specified in
section 4.2.2.
5.1.2.1 The number of complete compressor cycles over which the
measured temperatures in a compartment are to be averaged to
determine compartment temperature shall be equal to the number of
minutes between measured temperature readings, rounded up to the
next whole minute or a number of complete compressor cycles over a
time period exceeding 1 hour, whichever is greater. One of the
compressor cycles shall be the last complete compressor cycle during
the test period.
5.1.2.2 If no compressor cycling occurs, the compartment
temperature shall be the average of the measured temperatures taken
during the last 32 minutes of the test period.
5.1.2.3 If incomplete compressor cycling occurs, the compartment
temperatures shall be the average of the measured temperatures taken
during the last three hours of the last complete compressor ``on''
period.
5.1.3 Fresh Food Compartment Temperature. The fresh food
compartment temperature shall be calculated as:
[GRAPHIC] [TIFF OMITTED] TR02MY11.090
[[Page 24782]]
Where:
R is the total number of applicable fresh food compartments, which
include the first fresh food compartment and any number of separate
auxiliary fresh food compartments (including separate auxiliary
convertible compartments tested as fresh food compartments in
accordance with section 2.7);
TRi is the compartment temperature of fresh food
compartment ``i'' determined in accordance with section 5.1.2; and
VRi is the volume of fresh food compartment ``i''.
5.1.4 Freezer Compartment Temperature. The freezer compartment
temperature shall be calculated as:
[GRAPHIC] [TIFF OMITTED] TR02MY11.091
Where:
F is the total number of applicable freezer compartments, which include
the first freezer compartment and any number of separate auxiliary
freezer compartments (including separate auxiliary convertible
compartments tested as freezer compartments in accordance with section
2.7);
TFi is the compartment temperature of freezer compartment
``i'' determined in accordance with section 5.1.2; and
VFi is the volume of freezer compartment ``i''.
* * * * *
Appendix B1 [Corrected]
0
5. In Appendix B1 to subpart B of part 430, revise introductory
paragraph 5.1 to read as follows:
Appendix B1 to Subpart B of Part 430--Uniform Test Method for Measuring
the Energy Consumption of Freezers
* * * * *
5. Test Measurements
5.1 Temperature Measurements. Temperature measurements shall be
made at the locations prescribed in Figure 7.2 of HRF-1-1979
(incorporated by reference; see Sec. 430.3) and shall be accurate
to within 0.5 [deg]F (0.3 [deg]C). If the interior
arrangements of the cabinet do not conform with those shown in
Figure 7.2 of HRF-1-1979, the product may be tested by relocating
the temperature sensors from the locations specified in the figures
to avoid interference with hardware or components within the
cabinet, in which case the specific locations used for the
temperature sensors shall be noted in the test data records
maintained by the manufacturer in accordance with 10 CFR 429.14, and
the certification report shall indicate that non-standard sensor
locations were used.
5.1.1 Measured Temperature. The measured temperature is to be
the average of all sensor temperature readings taken at a particular
time. Measurements shall be taken at regular intervals not to exceed
four minutes.
5.1.2 Compartment Temperature. The compartment temperature for
each test period shall be an average of the measured temperatures
taken during one or more complete compressor cycles. One compressor
cycle is one complete motor ``on'' and one complete motor ``off''
period. For long-time automatic defrost models, compartment
temperature shall be that measured in the first part of the test
period specified in 4.2.1. For models equipped with variable defrost
controls, compartment temperatures shall be those measured in the
first part of the test period specified in 4.2.2.
5.1.2.1 The number of complete compressor motor cycles over
which the measured temperatures in a compartment are to be averaged
to determine compartment temperature shall be equal to the number of
minutes between measured temperature readings rounded up to the next
whole minute or a number of complete cycles over a time period
exceeding one hour. One of the compressor cycles shall be the last
complete compressor cycle during the test period before start of the
defrost control sequence for products with automatic defrost.
5.1.2.2 If no compressor motor cycling occurs, the compartment
temperature shall be the average of the measured temperatures taken
during the last thirty-two minutes of the test period.
5.1.2.3 If incomplete cycling occurs (less than one compressor
cycle), the compartment temperature shall be the average of all
readings taken during the last 3 hours of the last complete
compressor ``on'' period.
5.1.3 Freezer Compartment Temperature. The freezer compartment
temperature shall be calculated as:
[GRAPHIC] [TIFF OMITTED] TR02MY11.092
Where:
F is the total number of applicable freezer compartments, which
include the first freezer compartment and any number of separate
auxiliary freezer compartments;
TFi is the compartment temperature of freezer compartment
``i'' determined in accordance with section 5.1.2; and
VFi is the volume of freezer compartment ``i''.
* * * * *
Issued in Washington, DC, on April 22, 2011.
Kathleen Hogan,
Deputy Assistant Secretary for Energy Efficiency, Office of Technology
Development, Energy Efficiency and Renewable Energy.
[FR Doc. 2011-10401 Filed 4-29-11; 8:45 am]
BILLING CODE 6450-01-P