Sec. 3280.106  Exit facilities; egress windows and devices.

    (a) Every room designed expressly for sleeping purposes, unless it 
has an exit door (see Sec. 3280.105), shall have at least one outside 
window or approved exit device which meets the requirements of 
Sec. 3280.404, the ``Standard for Egress Windows and Devices for Use in 
Manufactured Homes.''
    (b) The bottom of the window opening shall not be more than 36 
inches above the floor.
    (c) Locks, latches, operating handles, tabs, and any other window 
screen or storm window devices which need to be operated in order to 
permit exiting, shall not be located in excess of 54 inches from the 
finished floor.
    (d) Integral rolled-in screens shall not be permitted in an egress 
window unless the window is of the hinged-type.

[49 FR 58752, Dec. 18, 1975. Redesignated at 44 FR 20679, Apr. 6, 1979, 