                 TITLE 24--HOUSING AND URBAN DEVELOPMENT
 
 CHAPTER XX--OFFICE OF ASSISTANT SECRETARY FOR HOUSING--FEDERAL HOUSING 
        COMMISSIONER, DEPARTMENT OF HOUSING AND URBAN DEVELOPMENT
 
PART 3280--MANUFACTURED HOME CONSTRUCTION AND SAFETY STANDARDS--Table of Contents
 
                   Subpart B--Planning Considerations
 
Sec. 3280.112  Hallways.

    Hallways shall have a minimum horizontal dimension of 28 inches 
measured from the interior finished surface to the interior finished 
surface of the opposite wall. When appliances are installed in a laundry 
area, the measurement shall be from the front of the appliance to the 
opposite finished interior surface. When appliances are not installed 
and a laundry area is provided, the area shall have a minimum clear 
depth of 27 inches in addition to the 28 inches required for passage. In 
addition, a notice of the available clearance for washer/dryer units 
shall be posted in the laundry area. Minor protrusions into the minimum 
hallway width by doorknobs, trim, smoke detectors or light fixtures are 
permitted.

[40 FR 58752, Dec. 18, 1975. Redesignated at 44 FR 20679, Apr. 6, 1979, 
and further redesignated at 58 FR 55004, Oct. 25, 1993]