                            TITLE 10--ENERGY
 
                    CHAPTER II--DEPARTMENT OF ENERGY
 
PART 435--ENERGY CONSERVATION VOLUNTARY PERFORMANCE STANDARDS FOR NEW BUILDINGS; MANDATORY FOR FEDERAL BUILDINGS--Table of Contents
 
 Subpart C--Mandatory Performance Standards for New Federal Residential 
                                Buildings
 
Sec. 435.305  Alternative compliance procedure.

    (a) If a proposed building design includes unusual or innovative 
energy conservation measures which are not covered by the COSTSAFR 
program, the Federal agency shall determine whether that design meets or 
exceeds the applicable energy consumption goal in compliance with the 
procedures set forth in this section.
    (b) The Federal agency shall determine the estimated discounted 
energy cost for the COSTSAFR prototype building design, which is the 
most similar of the COSTSAFR prototypes to the proposed building design, 
by--
    (1) Printing out the COSTSAFR compliance forms for the prototype 
showing the points attributable to levels of various energy conservation 
measures;
    (2) Calculating the estimated unit energy cost on the compliance 
forms, on

[[Page 619]]

the basis of selecting the optimum levels on the compliance forms or 
otherwise in the User's Manual for each energy conservation measure; and
    (3) Multiplying the estimated unit energy cost by 100.
    (c) The Federal agency shall determine the estimated discounted 
energy cost for the proposed building design by--
    (1) Estimating the heating and cooling total annual coil loads of 
the proposed building design with the DOE 2.1C computer program on the 
basis of input assumptions including--
    (i) Shading coefficients of 0.6 for summer and 0.8 for winter;
    (ii) Thermostat setpoints of 78 degrees Fahrenheit for cooling, 70 
degrees Fahrenheit for heating (6 am to 12 midnight), and 60 degrees 
Fahrenheit for Night Setback (12 midnight to 6 am, except for houses 
with heat pumps);
    (iii) The infiltration rate measured in air changes per hour as 
calculated using appendix B of the COSTSAFR User's Manual;
    (iv) Natural venting with a constant air change rate of 10 air 
changes per hour--
    (A) When the outdoor temperature is lower than the indoor 
temperature, but not above 78 degrees Fahrenheit; and
    (B) When the enthalpy of the outdoor air is lower than the indoor 
air.
    (v) Internal gains in accordance with the following table for a 
house with 1540 square feet of floor area, adjusted by 0.35 Btu/ft \2\/
hr to account for changes in lighting as the floor area varies from 1540 
square feet--

                  Table 1--Internal Gain Schedule (Btu)
------------------------------------------------------------------------
                    Hour of day                      Sensible    Latent
------------------------------------------------------------------------
1.................................................        1139       247
2.................................................        1139       247
3.................................................        1139       247
4.................................................        1139       247
5.................................................        1139       247
6.................................................        1903       412
7.................................................        2391       518
8.................................................        4782      1036
9.................................................        2790       604
10................................................        1707       370
11................................................        1707       370
12................................................        2277       493
13................................................        1707       370
14................................................        1424       308
15................................................        1480       321
16................................................        1480       321
17................................................        2164       469
18................................................        2334       506
19................................................        2505       543
20................................................        3928       851
21................................................        3928       851
22................................................        4101       888
23................................................        4101       888
24................................................        3701       802
------------------------------------------------------------------------

    (vi) Thermal transmittances for building envelope materials measured 
in accordance with applicable ASTM procedures or from the ASHRAE 
Handbook;
    (vii) Proposed heating and cooling equipment types included in 
COSTSAFR or having a certified seasonal efficiency rating;
    (viii) Weather Year for Energy Calculations (WYEC) weather year data 
(WYEC data are on tapes available from ASHRAE, 1791 Tullie Circle, N.E., 
Atlanta, Georgia 30329), or if unavailable, Test Reference Year (TRY) 
weather data (obtainable from National Climatic Data Center, 1983 Test 
Reference Year, Tape Reference Manual, TD-9706, Asheville, North 
Carolina) relevant to project location.
    (2) Estimating the discounted energy cost for the heating and 
cooling energy loads, respectively, according to the following 
equation--

[GRAPHIC] [TIFF OMITTED] TC14NO91.084

Where:
Total Annual Coil Load=the total heating or cooling annual coil load 
          calculated under paragraph (c)(1);
Fuel Cost=the heating or cooling fuel cost calculated in accordance with 
          sections 3.3.D and 3.3.E of the User's Manual;

[[Page 620]]

UPW*=the uniform present worth discount factor; selected from the last 
          page of the compliance forms.
Equipment Efficiency=the test seasonal efficiency rating of the heating 
          and cooling equipment only (i.e., not including duct or 
          distribution system losses).

    (3) Estimating the discounted energy cost for water heating and 
refrigerator/freezer energy consumption--
    (i) For equipment types covered by the COSTSAFR compliance forms, by 
multiplying the estimated unit energy cost by 100; or
    (ii)For equipment types not covered by COSTSAFR--

    [GRAPHIC] [TIFF OMITTED] TC14NO91.085
    
Where:
Fuel Cost and UPW* are as defined in paragraph (c)(2) of this section; 
          Annual Energy Consumption is as calculated in 10 CFR 430.22; 
          and Energy Factor is the measure of energy efficiency as 
          calculated under 10 CFR 430.22

    (iii) [Reserved]
    (4) Adding together the discounted energy costs calculated under 
paragraphs (c)(2) and (c)(3) of this section;
    (d) If the discounted energy cost of the proposed building design 
calculated under paragraph (c)(4) of this section is equal to or less 
than the discounted energy cost of the COSTSAFR prototype building 
design calculated under paragraph (b) of this section, then the proposed 
building design is in compliance with the applicable energy consumption 
goal under this part.

[56 FR 3772, Jan. 31, 1991]