[Code of Federal Regulations] [Title 10, Volume 4, Parts 500 to end] [Revised as of January 1, 2001] From the U.S. Government Printing Office via GPO Access [CITE: 10CFR835.402] [Page 461-462] TITLE 10--ENERGY CHAPTER III--DEPARTMENT OF ENERGY PART 835--OCCUPATIONAL RADIATION PROTECTION--Table of Contents Subpart E--Monitoring of Individuals and Areas Sec. 835.402 Individual monitoring. (a) For the purpose of monitoring individual exposures to external radiation, personnel dosimeters shall be provided to and used by: (1) Radiological workers who, under typical conditions, are likely to receive one or more of the following: (i) An effective dose equivalent to the whole body of 0.1 rem (0.001 sievert) or more in a year; [[Page 462]] (ii) A shallow dose equivalent to the skin or to any extremity of 5 rems (0.05 sievert) or more in a year; (iii) A lens of the eye dose equivalent of 1.5 rems (0.015 sievert) or more in a year; (2) Declared pregnant workers who are likely to receive from external sources a dose equivalent to the embryo/fetus in excess of 10 percent of the limit at Sec. 835.206(a); (3) Occupationally exposed minors likely to receive a dose in excess of 50 percent of the applicable limits at Sec. 835.207 in a year from external sources; (4) Members of the public entering a controlled area likely to receive a dose in excess of 50 percent of the limit at Sec. 835.208 in a year from external sources; and (5) Individuals entering a high or very high radiation area. (b) External dose monitoring programs implemented to demonstrate compliance with Sec. 835.402(a) shall be adequate to demonstrate compliance with the dose limits established in subpart C of this part and shall be: (1) Accredited, or excepted from accreditation, in accordance with the DOE Laboratory Accreditation Program for Personnel Dosimetry; or (2) Determined by the Secretarial Officer responsible for environment, safety and health matters to have performance substantially equivalent to that of programs accredited under the DOE Laboratory Accreditation Program for Personnel Dosimetry. (c) For the purpose of monitoring individual exposures to internal radiation, internal dosimetry programs (including routine bioassay programs) shall be conducted for: (1) Radiological workers who, under typical conditions, are likely to receive a committed effective dose equivalent of 0.1 rem (0.001 sievert) or more from all occupational radionuclide intakes in a year; (2) Declared pregnant workers likely to receive an intake or intakes resulting in a dose equivalent to the embryo/fetus in excess of 10 percent of the limit stated at Sec. 835.206(a); (3) Occupationally exposed minors who are likely to receive a dose in excess of 50 percent of the applicable limit stated at Sec. 835.207 from all radionuclide intakes in a year; or (4) Members of the public entering a controlled area likely to receive a dose in excess of 50 percent of the limit stated at Sec. 835.208 from all radionuclide intakes in a year. (d) Internal dose monitoring programs implemented to demonstrate compliance with Sec. 835.402(c) shall be adequate to demonstrate compliance with the dose limits established in subpart C of this part and shall be: (1) Accredited, or excepted from accreditation, in accordance with the DOE Laboratory Accreditation Program for Radiobioassay; or, (2) Determined by the Secretarial Officer responsible for environment, safety and health matters to have performance substantially equivalent to that of programs accredited under the DOE Laboratory Accreditation Program for Radiobioassy. [63 FR 59683, Nov. 4, 1998]