Sec. 183.435  Conductors in circuits of 50 volts or more.

    (a) Each conductor in a circuit that has a nominal voltage of 50 
volts or more must be:
    (1) A conductor that has insulation listed and classified moisture 
resistant and flame retardant in Article 310, NFPA No. 70, National 
Electric Code;
    (2) A flexible cord type SO, STO, ST, SJO, SJT, or SJTO listed in 
Article 400, NFPA No. 70, National Electric Code;
    (3) A conductor that meets IEEE Standard 45.
    (4) A conductor that meets UL Standard 1426.
    (b) Where the nominal circuit voltage of each of three or more 
current carrying conductors in a duct, bundle, or cable is 50 volts or 
more, the amperages of each of those conductors must not exceed the 
value in table 5 multiplied by the correction factor in note 2 to Table 
5 for the number of conductors that carry 50 volts or more.
    (c) This section does not apply to communication systems; electronic 
navigation equipment; resistance conductors that control circuit 
amperage; conductors in secondary circuits of ignition systems; and 
pigtails of less than seven inches of exposed length.