Sec. 23.7  Specific requirements for approval.

    (a) The circuits external to telephones and signal devices shall be 
intrinsically safe; that is, the electrical design and construction of 
telephones and signal devices shall be such that neither contact between 
wires comprising the external circuits nor contact of tools or other 
metal objects with external terminals and circuits will result in 
electrical sparks capable of igniting explosive methane-air mixtures (or 
such mixtures with coal dust in suspension) during normal operation of 
the telephones or signal devices.
    (b) All parts which, during normal operation, are capable of 
producing sparks that might ignite explosive methane-air mixtures shall 
be enclosed in explosion-proof compartments. All

[[Page 138]]

openings in the casings of such compartments shall be adequately 
protected. It is desirable that openings be as few as possible. All 
joints in the casings of an explosion-proof compartment shall be metal-
to-metal so designed as to have a width of contact, measured along the 
shortest path from the inside to the outside of the compartment, of not 
less than 1 inch if the unoccupied volume (air space) in the compartment 
is more than 60 cubic inches. For unoccupied volume of 60 cubic inches 
or less, a \3/8\-inch width of contact will be acceptable.
    (c) All bolts and screw holes shall be ``blind'' or bottomed if the 
omission of a bolt or screw would otherwise leave an opening into the 
compartment. An adequate lock or seal shall be provided to prevent 
tampering and exposure of spark-producing parts by unauthorized persons.
    (d) Battery cells shall be placed in an explosion-proof compartment 
or else in one that is locked or sealed, and the terminals and the 
connections thereto shall be so arranged and protected as to preclude 
meddling, tampering, or making other electrical connections with them.
    (e) Manufacturers shall furnish adequate instructions for the 
installation and connection of telephones and signal devices in order 
that the safety of these devices and other circuits shall not be 
diminished by improper installation. MSHA reserves the right to require 
the attachment of wiring diagrams to the cases of telephones and signal 
devices.
    (f) If electric light bulbs are used in signaling devices, they 
shall be either equipped with effective safety devices, such as are 
required for permissible electric mine lamps, 1 or enclosed 
in explosion-proof compartments.
---------------------------------------------------------------------------

     1  In this case, the requirements of the current 
schedule for mine lamps will apply.
---------------------------------------------------------------------------

    (g) Line powered telephones and signaling devices or systems shall 
be equipped with standby power sources that have the capacity to enable 
the devices or systems to continue functioning in the event the line 
power fails or is cut off. Manufacturers shall furnish instructions for 
the proper maintenance of standby power sources.
    Note: Paragraph (g) of this section is issued under the authority of 
Sec. 101 of the Federal Mine Safety and Health Act of 1977, Pub. L. 91-
173 as amended by Pub. L. 95-164, 91 Stat. 1291 (30 U.S.C. 811). All 
other paragraphs in this section continue under the original authority.