                       TITLE 30--MINERAL RESOURCES
 
  CHAPTER I--MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR
 
PART 7--TESTING BY APPLICANT OR THIRD PARTY--Table of Contents
 
                 Subpart D--Multiple-Shot Blasting Units
 
Sec. 7.64  Technical requirements.

    (a) Energy output. Blasting units shall meet the acceptable 
performance criteria of the output energy test in Sec. 7.66.
    (b) Maximum blasting circuit resistance. The maximum value of the 
resistance of the blasting circuit that can be connected to the firing 
line terminals of the blasting unit, without exceeding its capacity, 
shall be specified by the applicant. The specified maximum blasting 
circuit resistance shall be at least 150 ohms.
    (c) Visual indicator. The blasting unit shall provide a visual 
indication to the user prior to the operation of the firing switch when 
the voltage necessary to produce the required firing current is 
attained.
    (d) Firing switch. The switch used to initiate the application of 
energy to the blasting circuit shall--
    (1) Require deliberate action for its operation to prevent 
accidental firing; and
    (2) Operate only when the voltage necessary to produce the required 
firing current is available to the blasting circuit.
    (e) Firing line terminals. The terminals used to connect the 
blasting circuit to the blasting unit shall--
    (1) Provide a secure, low-resistance connection to the blasting 
circuit as demonstrated by the firing line terminals test in Sec. 7.68;
    (2) Be corrosion-resistant;
    (3) Be insulated to protect the user from electrical shock; and
    (4) Be separated from each other by an insulated barrier.
    (f) Ratings of electric components. No electric component of the 
blasting unit, other than batteries, shall be operated at more than 90 
percent of any of its electrical ratings in the normal operation of the 
blasting unit.
    (g) Non-incendive electric contacts. In the normal operation of a 
blasting unit, the electric energy discharged by making and breaking 
electric contacts shall not be capable of igniting a methane-air 
atmosphere, as determined by the following:
    (1) The electric current through an electric contact shall not be 
greater than that determined from Figure D-1.
    (2) The maximum voltage that can be applied across an electric 
contact that discharges a capacitor shall not be greater than that 
determined from Figure D-2.
    (3) The electric current through an electric contact that interrupts 
a circuit containing inductive components shall not be greater than that 
determined from Figure D-3. Inductive components include inductors, 
chokes, relay coils, motors, transformers, and similar electric 
components that have an inductance greater than 100 microhenries. No 
inductive component in a circuit with making and breaking electric 
contacts shall have an inductance value greater than 100 millihenries.

[[Page 24]]

[GRAPHIC] [TIFF OMITTED] TC22OC91.001


[[Page 25]]


[GRAPHIC] [TIFF OMITTED] TC22OC91.002


[[Page 26]]


[GRAPHIC] [TIFF OMITTED] TC22OC91.003

    (h) Maximum temperature. In the normal operation of the blasting 
unit, the maximum temperature of any electric component shall not exceed 
302  deg.F (150  deg.C).
    (i) Capacitor discharge. The blasting unit shall include an 
automatic means

[[Page 27]]

to dissipate any electric charge remaining in any capacitor after the 
blasting unit is deenergized and not in use.
    (j) Construction. Blasting units shall meet the acceptable 
performance criteria of the construction test of Sec. 7.67.
    (k) Locking device. The blasting unit shall be equipped with a 
locking device to prevent unauthorized use.
    (l) Enclosure. The blasting unit enclosure shall be protected 
against tampering by--
    (1) Sealing the enclosure, except the battery compartment, using 
continuous welding, brazing, soldering, or equivalent methods; or
    (2) Sealing the electric components, other than batteries, in a 
solidified insulating material and assembling the enclosure with tamper-
resistant hardware.
    (m) Battery charging. Blasting units that contain rechargeable 
batteries shall have the following:
    (1) A blocking diode, or equivalent device, in series with the 
battery to prevent electric energy in the battery from being available 
at the charging connector.
    (2) The charging connector recessed into the enclosure.