Sec. 7.68  Firing line terminals test.

    (a) Test procedures. (1) The contact resistance through each firing 
line terminal shall be determined.
    (2) A 10-pound pull shall be applied to a No. 18 gauge wire that has 
been connected to each firing line terminal according to the 
manufacturer's instructions.
    (b) Acceptable performance. (1) The contact resistance shall not be 
greater than 1 ohm.
    (2) The No. 18 gauge wire shall not become disconnected from either 
firing line terminal.