Sec. 75.326  Mean entry air velocity.

    In exhausting face ventilation systems, the mean entry air velocity 
shall be at least 60 feet per minute reaching each working face where 
coal is being cut, mined, drilled for blasting, or loaded, and to any 
other working places as required in the approved ventilation plan. A 
lower mean entry air velocity may be approved in the ventilation plan if 
the lower velocity will maintain methane and respirable dust 
concentrations in accordance with the applicable levels. Mean entry air 
velocity shall be determined at or near the inby end of the line 
curtain, ventilation tubing, or other face ventilation control devices.