[Code of Federal Regulations] [Title 33, Volume 2] [Revised as of July 1, 2002] From the U.S. Government Printing Office via GPO Access [CITE: 33CFR149.421] [Page 205-206] TITLE 33--NAVIGATION AND NAVIGABLE WATERS CHAPTER I--COAST GUARD, DEPARTMENT OF TRANSPORTATION (CONTINUED) PART 149--DESIGN, CONSTRUCTION, AND EQUIPMENT--Table of Contents Subpart D--Safety Equipment Sec. 149.421 Means of escape from platform. (a) Each platform must have at least one fixed and one unfixed means of escape from the highest working level to the water level with an entry at each working level. (b) Each platform with living spaces must have at least two fixed means of escape from the highest level with living spaces to the water with an entry at each level below. If the highest level of the PPC contains living spaces, the two fixed means of escape required by this paragraph satisfy the requirements in paragraph (a) of this section. (c) Each platform must have at least one fixed or unfixed means of escape for every ten persons on board the platform, including the means of escape required under paragraphs (a) and (b) of this section. (d) When two or more fixed means of escape are installed, at least two must be as far from each other as practicable. (e) Each fixed means of escape required under this section must be a steel ladder or steel stairway. (f) Each unfixed means of escape required under this section must be: (1) A portable ladder; [[Page 206]] (2) A flexible ladder; or (3) A knotted man rope. (g) Two exits must be provided from each space having over 300 square feet of floor area. Where practicable, the exits must give egress to different corridors, rooms, or spaces. (h) Exits must provide egress to the external means of escape required in this section. Dead end corridors may not be longer than 40 feet.