Sec. 141.62  Maximum contaminant levels for inorganic contaminants.

    (a) [Reserved]
    (b) The maximum contaminant levels for inorganic contaminants 
specified in paragraphs (b) (2)-(6), (b)(10), and (b) (11)-(16) of this 
section apply to community water systems and non-transient, non-
community water systems. The maximum contaminant level specified in 
paragraph (b)(1) of this section only applies to community water 
systems. The maximum contaminant levels specified in (b)(7), (b)(8), and 
(b)(9) of this section apply to community water systems; non-transient, 
non-community water systems; and transient non-community water systems.

------------------------------------------------------------------------
                Contaminant                          MCL (mg/l)
------------------------------------------------------------------------
(1) Fluoride..............................  4.0
(2) Asbestos..............................  7 Million Fibers/liter
                                             (longer than 10 [mu]m).
(3) Barium................................  2
(4) Cadmium...............................  0.005
(5) Chromium..............................  0.1
(6) Mercury...............................  0.002
(7) Nitrate...............................  10 (as Nitrogen)
(8) Nitrite...............................  1 (as Nitrogen)
(9) Total Nitrate and Nitrite.............  10 (as Nitrogen)
(10) Selenium.............................  0.05
(11) Antimony.............................  0.006
(12) Beryllium............................  0.004
(13) Cyanide (as free Cyanide)............  0.2
(14) [Reserved]...........................  ............................
(15) Thallium.............................  0.002
(16) Arsenic..............................  0.01
------------------------------------------------------------------------

    (c) The Administrator, pursuant to section 1412 of the Act, hereby 
identifies the following as the best technology, treatment technique, or 
other means available for achieving compliance with the maximum 
contaminant levels for inorganic contaminants identified in paragraph 
(b) of this section, except fluoride:

          BAT FOR INORGANIC COMPOUNDS LISTED IN SECTION 141.62(b)
------------------------------------------------------------------------
                      Chemical Name                           BAT(s)
------------------------------------------------------------------------
Antimony................................................             2,7
Arsenic \4\.............................................  1, 2, 5, 6, 7,
                                                               9, 12 \5\

[[Page 429]]


Asbestos................................................           2,3,8
Barium..................................................         5,6,7,9
Beryllium...............................................       1,2,5,6,7
Cadmium.................................................         2,5,6,7
Chromium................................................     2,5,6 \2\,7
Cyanide.................................................          5,7,10
Mercury.................................................  2 \1\,4,6 \1\,
                                                                   7 \1\
Nickel..................................................           5,6,7
Nitrate.................................................           5,7,9
Nitrite.................................................             5,7
Selenium................................................   1,2 \3\,6,7,9
Thallium................................................             1,5
------------------------------------------------------------------------
\1\ BAT only if influent Hg concentrations [le]10[mu]g/1.
\2\ BAT for Chromium III only.
\3\ BAT for Selenium IV only.
\4\ BATs for Arsenic V. Pre-oxidation may be required to convert Arsenic
  III to Arsenic V.
\5\ To obtain high removals, iron to arsenic ratio must be at least
  20:1.

                          Key to BATS in Table

1=Activated Alumina
2 = Coagulation/Filtration (not BAT for systems < 500 service 
connections)
2=Coagulation/Filtration
3=Direct and Diatomite Filtration
4=Granular Activated Carbon
5=Ion Exchange
6 = Lime Softening (not BAT for systems < 500 service connections)
7=Reverse Osmosis
8=Corrosion Control
9=Electrodialysis
10=Chlorine
11=Ultraviolet
12 = Oxidation/Filtration
    (d) The Administrator, pursuant to section 1412 of the Act, hereby 
identifies in the following table the affordable technology, treatment 
technique, or other means available to systems serving 10,000 persons or 
fewer for achieving compliance with the maximum contaminant level for 
arsenic:

    Small System Compliance Technologies (SSCTs) \1\ for Arsenic \2\
------------------------------------------------------------------------
                                             Affordable for listed small
    Small system compliance technology          system categories \3\
------------------------------------------------------------------------
Activated Alumina (centralized)...........  All size categories.
Activated Alumina (Point-of-Use) \4\......  All size categories.
Coagulation/Filtration \5\................  501-3,300, 3,301-10,000.
Coagulation-assisted Microfiltration......  501-3,300, 3,301-10,000.
Electrodialysis reversal \6\..............  501-3,300, 3,301-10,000.
Enhanced coagulation/filtration...........  All size categories
Enhanced lime softening (pH      All size categories.
 10.5).
Ion Exchange..............................  All size categories.
Lime Softening \5\........................  501-3,300, 3,301-10,000.
Oxidation/Filtration \7\..................  All size categories.
Reverse Osmosis (centralized) \6\.........  501-3,300, 3,301-10,000.
Reverse Osmosis (Point-of-Use) \4\........  All size categories.
------------------------------------------------------------------------
\1\ Section 1412(b)(4)(E)(ii) of SDWA specifies that SSCTs must be
  affordable and technically feasible for small systems.
\2\ SSCTs for Arsenic V. Pre-oxidation may be required to convert
  Arsenic III to Arsenic V.
\3\ The Act (ibid.) specifies three categories of small systems: (i)
  those serving 25 or more, but fewer than 501, (ii) those serving more
  than 500, but fewer than 3,301, and (iii) those serving more than
  3,300, but fewer than 10,001.
\4\ When POU or POE devices are used for compliance, programs to ensure
  proper long-term operation, maintenance, and monitoring must be
  provided by the water system to ensure adequate performance.
\5\ Unlikely to be installed solely for arsenic removal. May require pH
  adjustment to optimal range if high removals are needed.
\6\ Technologies reject a large volume of water--may not be appropriate
  for areas where water quantity may be an issue.
\7\ To obtain high removals, iron to arsenic ratio must be at least
  20:1.


[56 FR 3594, Jan. 30, 1991, as amended at 56 FR 30280, July 1, 1991; 57 
FR 31847, July 17, 1992; 59 FR 34325, July 1, 1994; 60 FR 33932, June 
29, 1995; 66 FR 7063, Jan. 22, 2001]