[Code of Federal Regulations] [Title 40, Volume 25] [Revised as of July 1, 2002] From the U.S. Government Printing Office via GPO Access [CITE: 40CFR424.15] [Page 654] TITLE 40--PROTECTION OF ENVIRONMENT CHAPTER I--ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) PART 424--FERROALLOY MANUFACTURING POINT SOURCE CATEGORY--Table of Contents Subpart A--Open Electric Furnaces With Wet Air Pollution Control Devices Subcategory Sec. 424.15 Standards of performance for new sources. The following standards of performance establish the quantity or quality of pollutants or pollutant properties, controlled by this section, which may be discharged by a new source subject to the provisions of this subpart: ------------------------------------------------------------------------ Effluent limitations ----------------------------- Average of daily Effluent characteristic Maximum values for 30 for any 1 consecutive days day shall not exceed- - ------------------------------------------------------------------------ Metric units (kg/Mwh) ------------- TSS....................................... 0.024 0.012 Chromium total............................ .0008 .0004 Chromium VI............................... .00008 .00004 Manganese total........................... .008 .0039 pH........................................ (\1\) (\1\) ------------- English units (lb/Mwh) ------------- TSS....................................... .052 .026 Chromium total............................ .0017 .0009 Chromium VI............................... .0002 .0001 Manganese total........................... .017 .0086 pH........................................ (\1\) (\1\) ------------------------------------------------------------------------ \1\ Within the range 6.0 to 9.0.