[Code of Federal Regulations]
[Title 49, Volume 3]
[Revised as of October1, 2002]
From the U.S. Government Printing Office via GPO Access
[CITE: 49CFR195.134]

[Page 139]
 
                        TITLE 49--TRANSPORTATION
 
 CHAPTER I--RESEARCH AND SPECIAL PROGRAMS ADMINISTRATION, DEPARTMENT OF 
                       TRANSPORTATION (CONTINUED)
 
PART 195--TRANSPORTATION OF HAZARDOUS LIQUIDS BY PIPELINE--Table of Contents
 
                     Subpart C--Design Requirements
 
Sec. 195.134  CPM leak detection.

    This section applies to each hazardous liquid pipeline transporting 
liquid in single phase (without gas in the liquid). On such systems, 
each new computational pipeline monitoring (CPM) leak detection system 
and each replaced component of an existing CPM system must comply with 
section 4.2 of API 1130 in its design and with any other design criteria 
addressed in API 1130 for components of the CPM leak detection system.

[Amdt. 195-62, 63 FR 36376, July 6, 1998]