[Code of Federal Regulations] [Title 49, Volume 4] [Revised as of October 1, 2002] From the U.S. Government Printing Office via GPO Access [CITE: 49CFR230.48] [Page 331-332] TITLE 49--TRANSPORTATION CHAPTER II--FEDERAL RAILROAD ADMINISTRATION, DEPARTMENT OF TRANSPORTATION PART 230--STEAM LOCOMOTIVE INSPECTION AND MAINTENANCE STANDARDS--Table of Contents Subpart B--Boilers and Appurtenances Sec. 230.48 Number and capacity. (a) Number and capacity. Every boiler shall be equipped with at least two safety relief valves, suitable for the service intended, that are capable of preventing an accumulation of pressure greater than 6 percent above the MAWP under any conditions of service. An FRA inspector may require verification of sufficient safety valve relieving capacity. (b) Determination of capacity. Safety relief valve capacity may be determined by making an accumulation test with the fire in good, bright condition [[Page 332]] and all steam outlets closed. Additional safety relief valve capacity shall be provided if the safety relief valves allow an excess pressure of more than 6 percent above the MAWP during this test.