[Code of Federal Regulations] [Title 49, Volume 4] [Revised as of October 1, 2002] From the U.S. Government Printing Office via GPO Access [CITE: 49CFR234.243] [Page 477] TITLE 49--TRANSPORTATION CHAPTER II--FEDERAL RAILROAD ADMINISTRATION, DEPARTMENT OF TRANSPORTATION PART 234--GRADE CROSSING SIGNAL SYSTEM SAFETY--Table of Contents Subpart D--Maintenance, Inspection, and Testing Sec. 234.243 Wire on pole line and aerial cable. Wire on a pole line shall be securely attached to an insulator that is properly fastened to a cross arm or bracket supported by a pole or other support. Wire shall not interfere with, or be interfered with by, other wires on the pole line. Aerial cable shall be supported by messenger wire. An open-wire transmission line operating at voltage of 750 volts or more shall be placed not less than 4 feet above the nearest cross arm carrying active warning system circuits.