Sec. 234.269  Cut-out circuits.

    Each cut-out circuit shall be tested at least once every three 
months to determine that the circuit functions as intended. For purposes 
of this section, a cut-out circuit is any circuit which overrides the 
operation of automatic warning systems. This includes both switch cut-
out circuits and devices which enable personnel to manually override the 
operation of automatic warning systems.