Sec. 236.2  Grounds.

    Each circuit, the functioning of which affects the safety of train 
operations, shall be kept free of any ground or combination of grounds 
which will permit a flow of current equal to or in excess of 75 percent 
of the release value of any relay or other electromagnetic device in the 
circuit, except circuits which include any track rail and except the 
common return wires of single-wire, single-break, signal control 
circuits using a grounded common, and alternating current power 
distribution circuits which are grounded in the interest of safety.