[Code of Federal Regulations]
[Title 49, Volume 5]
[Revised as of October 1, 2002]
From the U.S. Government Printing Office via GPO Access
[CITE: 49CFR572.35]

[Page 789-794]
 
                        TITLE 49--TRANSPORTATION
 
                            OF TRANSPORTATION
 
PART 572--ANTHROPOMORPHIC TEST DEVICES--Table of Contents
 
                    Subpart E--Hybrid III Test Dummy
 
Sec. 572.35  Limbs.

    (a) The limbs consist of the following assemblies: leg assemblies 
86-5001-001, revision A and -002, revision A, and arm assemblies 78051-
123, revision D and -124, revision D, and shall conform to the drawings 
subtended therein.
    (b) Femur impact response. (1) When each knee of the leg assemblies 
is impacted in accordance with paragraph (b)(2) of this section, at 6.9 
ft/sec 0.10 ft/sec by the pendulum defined in 
Sec. 572.36(b), the peak knee impact force, which is a product of 
pendulum mass and acceleration, shall have a minimum value of not less 
than 1060 pounds and a maximum value of not more than 1300 pounds.
    (2) Test procedure. (i) The test material consists of leg assemblies 
(86-5001-001, revision A) left and (-002, revision A) right with upper 
leg assemblies (78051-46) left and (78051-47) right removed. The load 
cell simulator (78051-319, revision A) is used to secure the knee cap 
assemblies (79051-16, revision B) as shown in Figure 24.
    (ii) Soak the test material in a test environment at any temperature 
between 66 degrees F to 78 degrees F and at a relative humidity from 10% 
to 70% for a period of at least four hours prior to its application in a 
test.
    (iii) Mount the test material with the leg assembly secured through 
the load cell simulator to a rigid surface as shown in Figure 24. No 
contact is permitted between the foot and any other exterior surfaces.
    (iv) Place the longitudinal centerline of the test probe so that at 
contact with the knee it is collinear within 2 degrees with the 
longitudinal centerline of the femur load cell simulator.
    (v) Guide the pendulum so that there is no significant lateral, 
vertical or rotational movement at time zero.
    (vi) Impact the knee with the test probe so that the longitudinal 
centerline of the test probe at the instant of impact falls within .5 
degrees of a horizontal line parallel to the femur load cell simulator 
at time zero.
    (vii) Time zero is defined as the time of contact between the test 
probe and the knee.
    (c) Hip joint-femur flexion. (1) When each femur is rotated in the 
flexion direction in accordance with paragraph (c)(2) of this section, 
the femur torque at 30 deg. rotation from its initial horizontal 
orientation will not be more than 70 ft-lbf, and at 150 ft-lbf of torque 
will not be less than 40 deg. or more than 50 deg.
    (2) Test procedure. (i) The test material consists of the assembled 
dummy, part No. 78051-218 (revision S) except that (1) leg assemblies 
(86-5001-001 and 002) are separated from the dummy by removing the 3/8-
16 Socket Head Cap Screw (SHCS) (78051-99) but retaining the structural 
assembly of the upper legs (78051-43 and -44), (2) the abdominal insert 
(78051-52) is removed and (3) the instrument cover plate (78051-13) in 
the pelvic bone is replaced by a rigid pelvic bone stabilizer insert 
(Figure 25a) and firmly secured.
    (ii) Seat the dummy on a rigid seat fixture (Figure 25) and firmly 
secure it to the seat back by bolting the stabilizer insert and the 
rigid support device (Figure 25b) to the seat back of the test fixture 
(Figures 26 and 27) while

[[Page 790]]

maintaining the pelvis (78051-58) ``B'' plane horizontal.
    (iii) Insert a lever arm into the femur shaft opening of the upper 
leg structure assembly (78051-43/44) and firmly secure it using the 3/8-
16 socket head cap screws.
    (iv) Lift the lever arm parallel to the midsagittal plane at a 
rotation rate of 5 to 10 deg. per second while maintaining the 1/2 in. 
shoulder bolt longitudinal centerline horizontal throughout the range of 
motion until the 150 ft-lbf torque level is reached. Record the torque 
and angle of rotation of the femur.
    (v) Operating environment and temperature are the same as specified 
in paragraph (b)(2)(ii) of this section.
[GRAPHIC] [TIFF OMITTED] TC01AU91.167


[[Page 791]]


[GRAPHIC] [TIFF OMITTED] TR26DE96.004


[[Page 792]]


[GRAPHIC] [TIFF OMITTED] TR26DE96.005

[GRAPHIC] [TIFF OMITTED] TR26DE96.006


[[Page 793]]


[GRAPHIC] [TIFF OMITTED] TR26DE96.007


[[Page 794]]


[GRAPHIC] [TIFF OMITTED] TR26DE96.008


[51 FR 26701, July 25, 1986, as amended at 53 FR 8765, Mar. 17, 1988; 61 
FR 67955, Dec. 26, 1997; 63 FR 5748, Feb. 4, 1998]