[Code of Federal Regulations] [Title 14, Volume 1] [Revised as of January 1, 2003] From the U.S. Government Printing Office via GPO Access [CITE: 14CFR31.46] [Page 730] TITLE 14--AERONAUTICS AND SPACE CHAPTER I--FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF TRANSPORTATION PART 31--AIRWORTHINESS STANDARDS: MANNED FREE BALLOONS--Table of Contents Subpart D--Design Construction Sec. 31.46 Pressurized fuel systems. For pressurized fuel systems, each element and its connecting fittings and lines must be tested to an ultimate pressure of at least twice the maximum pressure to which the system will be subjected in normal operation. No part of the system may fail or malfunction during the test. The test configuration must be representative of the normal fuel system installation and balloon configuration. [Amdt. 31-3, 41 FR 55474, Dec. 20, 1976]