Sec. 1211.5 General testing parameters.
(a) The following test parameters are to be used in the
investigation of the circuit covered by Sec. 1211.4(c) for compliance
with the Standard for Safety for Tests for Safety-Related Controls
Employing Solid-State Devices, UL 991, second edition, dated June 23,
1995, as incorporated by reference in paragraph (b)(3) of this section:
(1) With regard to electrical supervision of critical components, an
operator being inoperative with respect to downward movement of the door
meets the criteria for trouble indication.
(2) A field strength of 3 volts per meter is to be used for the
Radiated EMI Test.
(3) The Composite Operational and Cycling Test is to be used for 14
days at temperature extremes of minus 35 deg.Celsius (minus 31 deg.F)
and 70 deg.C (158 deg.F).
(4) Exposure Class H5 is to be used for the Humidity Test.
(5) A vibration level of 5g is to be used for the Vibration Test.
(6) When a Computational Investigation is conducted,
[lgr]p shall not be greater than 6 failures/10\6\ hours for
the entire system. For external secondary entrapment protection devices
that are sold separately, [lgr]p shall not be greater than 0
failures/10\6\ hours. For internal
[[Page 324]]
secondary entrapment protection devices whether or not they are sold
separately, [lgr]p shall not be greater than 0 failures/10\6\
hours. The operational test is conducted for 14 days. An external
secondary entrapment protection device that is sold separately, and that
has a [lgr]p greater than 0 failures/10\6\ hours meets the
intent of the requirement when for the combination of the operator and
the specified external secondary entrapment protection device
[lgr]p does not exceed 6 failures/10\6\ hours. See
Sec. 1211.15(i) and (k).
(7) When the Demonstrated Method Test is conducted, the multiplier
is to be based on the continuous usage level, and a minimum of 24 units
for a minimum of 24 hours per unit are to be tested.
(8) The Endurance test is to be conducted concurrently with the
Operational test. The control shall perform its intended function while
being conditioned for fourteen days in an ambient air temperature of 60
deg.C (140 deg.F), or 10 deg.C (18 deg.F) greater than the operating
temperature of the control, whichever is higher. During the test, the
control is to be operated in a manner representing the opening and
closing of the door at a rate of one open-close operation per minute.
(9) For the Electrical Fast Transient Burst Test, test level 3 is to
be used for residential garage door operators.
(b) In the evaluation of entrapment protection circuits used in
residential garage door operators, the critical condition flow chart
shown in figure 1 shall be used:
(1) To conduct a failure-mode and effect analysis (FMEA);
(2) In investigating the performance during the Environmental Stress
Tests; and
(3) During the Power Cycling Safety for Tests in accordance with the
Standard for Safety for Tests for Safety-Related Controls Employing
Solid-State Devices, UL 991, second edition, dated June 23, 1995. This
incorporation by reference was approved by the Director of the Federal
Register in accordance with 5 U.S.C. 552(a) and 1 CFR part 51. Copies
may be obtained from Global Engineering Documents, 15 Inverness Way
East, Englewood, CO 80112, Telephone (800) 854-7179 or Global
Engineering Documents, 7730 Carondelet Ave., Suite 470, Clayton, MO
63105, Telephone (800) 854-7179. Copies may be inspected at the Consumer
Product Safety Commission, Office of the Secretary, 4330 East West
Highway, Bethesda, Maryland or at the Office of the Federal Register,
800 North Capitol Street, NW., suite 700, Washington, DC.
[57 FR 60455, Dec. 21, 1992, as amended at 62 FR 46667, Sept. 4, 1997;
65 FR 70657, Nov. 27, 2000]