[Code of Federal Regulations]
[Title 7, Volume 11]
[Revised as of January 1, 2003]
From the U.S. Government Printing Office via GPO Access
[CITE: 7CFR1728.97]

[Page 278-279]
 
                          TITLE 7--AGRICULTURE
 
    CHAPTER XVII--RURAL UTILITIES SERVICE, DEPARTMENT OF AGRICULTURE
 
PART 1728--ELECTRIC STANDARDS AND SPECIFICATIONS FOR MATERIALS AND CONSTRUCTION--Table of Contents
 
Sec. 1728.97  Incorporation by reference of electric standards and specifications.

    (a) The following electric bulletins have been approved for 
incorporation by reference by the Director of the Office of the Federal 
Register. The bulletins containing construction standards (50-3 to 50-6 
and 1728F-803 to 1728F-811), may be purchased from the Superintendent of 
Documents, U.S. Government Printing Office, Washington, DC 20402. The 
bulletins containing specifications for materials and equipment (50-15 
to 50-99 and 1728F-700) may be obtained from the Rural Utilities 
Service, Program Development and Regulatory Analysis, Stop 1522, Room 
4028-S, Washington, DC 20250-1522. The terms ``RUS form'', ``RUS 
standard form'', ``RUS specification'', and ``RUS bulletin'' have the 
same meanings as the terms ``REA form'', ``REA standard form'', ``REA 
specification'', and ``REA bulletin'', respectively unless otherwise 
indicated. The bulletins are available for inspection at the Office of 
the Federal Register, 800 North Capitol Street, NW, Suite 700, 
Washington, DC. These materials are incorporated as they exist on the 
date of the approval and a notice of any change in these materials will 
be published in the Federal Register.
    (b) List of Bulletins.

Bulletin 50-3 (D-804), Specifications and Drawings for 12.5/7.2 kV Line 
Construction (4-83)
Bulletin 50-4 (D-801), Specification and Drawings for 34.5/19.9 kV 
Distribution Line Construction (11-86)
Bulletin 50-6 (D-806), Specifications and Drawings for Underground 
Electric Distribution (3-90)
Bulletin 50-15 (DT-3), RUS Specifications for Pole Top Pins with 1\3/
8\[foot] Diameter Lead Thread (1-51)
Bulletin 50-16 (DT-4), RUS Specifications for Angle Suspension Brackets 
(3-52)
Bulletin 50-19 (DT-7), RUS Specifications for Clevis Bolts (8-53)
Bulletin 50-23 (DT-18), RUS Specifications for 60 Wood 
Crossarm Braces (2-71)
Bulletin 50-31 (D-3), RUS Specifications for Pole Top Pins with 
1 Diameter Lead Threads (2-79)
Bulletin 50-32 (D-4), RUS Specifications for Steel Crossarm Mounted Pins 
with 1 Diameter Lead Threads (10-50)
Bulletin 50-33 (D-5), RUS Specifications for Single and Double Upset 
Spool Bolts (2-51)
Bulletin 50-34 (D-6), RUS Specifications for Secondary Swinging Clevises 
(12-70)
Bulletin 50-35 (D-7), RUS Specifications for Service Swinging Clevises 
(9-52)
Bulletin 50-36 (D-8), RUS Specifications for Service Deadend Clevises 
(9-52)
Bulletin 50-40 (D-14), RUS Specifications for Pole Top Brackets for 
Channel Type Pins (9-51)
Bulletin 50-41 (D-15), RUS Specifications for Service Wireholders (11-
51)
Bulletin 50-55 (T-2), RUS Specifications for Overhead Ground Wire 
Support Brackets (5-53)
Bulletin 50-56 (T-3), RUS Specifications for Steel Plate Anchors for 
Transmission Lines (12-53)
Bulletin 50-60 (T-9), RUS Specification--Single Pole Steel Structures, 
Complete with Arms (12-71)
Bulletin 50-70 (U-1), RUS Specification for 15 kV and 25 kV Primary 
Underground Power Cable (12-22-87)
Bulletin 50-72 (U-4), RUS Specification for Electrical Equipment 
Enclosures (5-35 kV) (10-79)
Bulletin 50-73 (U-5), RUS Specifications for Pad-Mounted Transformers 
(Single and Three-Phase) (1-77)
Bulletin 50-74 (U-6), RUS Specification for Secondary Pedestals (600 
Volts and Below) (10-79)

[[Page 279]]

Bulletin 50-91 (S-3), RUS Specifications for Step-Down Distribution 
Substation Transformers (34.4-138 kV) (1-78)
Bulletin 1728F-700, RUS Specification for Wood Poles, Stubs and Anchor 
Logs (8-93).
Bulletin 1728F-803, Specifications and Drawings for 24.9/14.4 kV Line 
Construction (10-98).
Bulletin 1728F-806 (D-806), Specifications and Drawings for Underground 
Electric Distribution, June 2000.
Bulletin 1728F-810, Electric Transmission Specifications and Drawings, 
34.5 kV to 69 kV (3-98).
Bulletin 1728F-811, Electric Transmission Specifications and Drawings, 
115 kV to 230 kV (3-98).

[48 FR 31853, July 12, 1983, as amended at 52 FR 22289, June 11, 1987; 
52 FR 48799, Dec. 28, 1987; 53 FR 39229, Oct. 6, 1988; 53 FR 44176, Nov. 
2, 1988; 55 FR 8909, Mar. 9, 1990. Redesignated at 55 FR 39395, Sept. 
27, 1990, as amended at 56 FR 1563, Jan. 16, 1991; 58 FR 41398, Aug. 3, 
1993; 59 FR 66440, Dec. 27, 1994; 63 FR 11591, Mar. 10, 1998; 63 FR 
72104, Dec. 31, 1998; 65 FR 34047, May 26, 2000]