[Code of Federal Regulations]
[Title 9, Volume 1]
[Revised as of January 1, 2003]
From the U.S. Government Printing Office via GPO Access
[CITE: 9CFR113.52]

[Page 617-619]
 
                  TITLE 9--ANIMALS AND ANIMAL PRODUCTS
 
  CHAPTER I--ANIMAL AND PLANT HEALTH INSPECTION SERVICE, DEPARTMENT OF 
                               AGRICULTURE
 
PART 113--STANDARD REQUIREMENTS--Table of Contents
 
Sec. 113.52  Requirements for cell lines used for production of biologics.

    When prescribed in an applicable Standard Requirement or in a filed 
Outline of Production each cell line used to prepare a biological 
product shall be tested as prescribed in this section. A cell line found 
unsatisfactory

[[Page 618]]

by any prescribed test shall not be used. A serial of biological product 
shall not be released if produced from a cell line that is found 
unsatisfactory by any prescribed test.
    (a) General requirements. (1) A complete record of the cell line 
shall be kept, such as, but not limited to, the source, passage history, 
and medium used for propagation.
    (2) A Master Cell Stock (MCS) shall be established at a specified 
passage level for each cell line. The passage level and identity of the 
MCS and the highest passage level (MCS + n) intended for use in the 
preparation of a biological product shall be specified in the Outline of 
Production for the product.
    (3) Sufficient 1.0 ml or larger aliquots of MCS and MCS + n shall be 
prepared, kept in a frozen state, and made available to Animal and Plant 
Health Inspection Service (APHIS) upon request for performing the tests 
prescribed in this section.
    (4) Each lot of cells shall be monitored for the characteristics 
determined to be normal for the cell line, such as, but not limited to, 
microscopic appearance, growth rate, acid production, or other 
observable features.
    (b) The MCS shall be shown to be of the same species of origin as 
that reported in paragraph (a)(1) of this section by the following 
method:
    (1) At least four monolayers with a total area of at least 6 cm\2\ 
shall be grown to at least 80 percent confluency.
    (2) The monolayers shall be removed from their media, processed, 
stained, and examined.
    (i) At least two monolayers shall be stained with an antispecies 
fluorchrome-conjugated antibody unrelated to the species of origin of 
the MCS.
    (ii) At least two monolayers shall be stained with an antispecies 
fluorochrome-conjugated antibody specific to the species of origin of 
the MCS.
    (iii) All monolayers shall be examined for evidence of specific 
fluorescence.
    (3) If specific fluorescence is not found in the monolayers stained 
with the conjugate specific to the species of origin of the MCS, the 
cell line is unsatisfactory and shall not be used for vaccine 
production.
    (4) If nonspecific fluorescence is found in the monolayers stained 
with conjugate from an unrelated species of origin or other results make 
the test results equivocal, the procedure shall be repeated until either 
specific fluorescence is found only in the monolayers stained with 
conjugate specific to the species of origin of the MCS and not in the 
control monolayers or specific fluorescence cannot be identified and the 
MCS is declared unsatisfactory.
    (5) Alternate tests to determine the species of origin of the MCS 
may be used if approved by APHIS.
    (c) The MCS and either each subculture of cells used to prepare a 
biological product or the final pool of harvested material (with or 
without the stabilizer) or final container samples of completed product 
for each serial of such product shall be shown to be free of mycoplasma 
as prescribed in Sec. 113.28. The sample for testing shall consist of at 
least 75 cm\2\ of actively growing cells or the equivalent, in harvest 
fluids. The cells shall represent all sources of cells in the batch.
    (d) The MCS and either each subculture used to prepare a biological 
product or the final pool of harvested material for each serial of such 
product or final container samples of completed product for each serial 
of such product shall be tested for bacteria and fungi as prescribed in 
Sec. 113.26 or Sec. 113.27 (whichever is applicable). If bacteria or 
fungi are found in the MCS, the MCS shall not be used. If bacteria or 
fungi are found in a subculture, the subculture shall not be used.
    (e) A monolayer at least 75 cm\2\ from each MCS shall be shown free 
of extraneous agents as prescribed in this paragraph.
    (1) The test monolayer shall be maintained for at least 21 days 
using the medium (with additives) intended for growth and maintenance 
and under conditions similar to those used to prepare biological 
products.
    (2) Cells shall be subcultured at least two times during the 
maintenance period. All but the last subculture shall

[[Page 619]]

result in at least one new monolayer of at least 75 cm\2\. The last 
subculture shall meet the minimum area requirement specified in 
Secs. 113.46 and 113.47 and paragraph (f) of this section.
    (3) Monolayers shall be examined regularly throughout the 21-day 
maintenance period for evidence of the presence of cytopathogenic 
agents. If evidence of a cytopathogenic agent is found, the MCS is 
unsatisfactory.
    (4) At the conclusion of the 21-day maintenance period, monolayers 
shall be tested for:
    (i) Cytopathogenic and/or hemadsorbing agents as prescribed in 
Sec. 113.46; and
    (ii) Extraneous agents by the fluorescent antibody technique as 
prescribed in Sec. 113.47.
    (f) At the conclusion of the 21-day maintenance period provided in 
paragraph (e) of this section, at least one monolayer of at least 75 
cm\2\ shall also be shown free of extraneous agents as prescribed in 
this paragraph.
    (1) Alternately freeze and thaw the monolayer(s) three times. 
Centrifuge the disrupted cells at no greater than 2,000xg for no more 
than 15 minutes to remove cellular debris. Divide the supernatant into 
equal aliquots and dispense 1.0 ml onto each of at least one monolayer 
(at least 75 cm\2\) of:
    (i) Vero (African green monkey kidney) cell line;
    (ii) Embryonic cells, neonatal cells, or a cell line of the same 
species of origin as the MCS if different than provided in paragraph 
(f)(1)(i) of this section;
    (iii) Embryonic cells, neonatal cells, or a cell line of the species 
for which the vaccine is recommended if different than provided in 
paragraph (f)(1)(ii) of this section; and
    (iv) Embryonic cells, neonatal cells, or a cell line of bovine 
origin if not specified in paragraphs (f)(1)(ii), and (iii) of this 
section.
    (2) The monolayers of cells specified in paragraphs (f)(1)(i), (ii), 
(iii), and (iv) of this section shall be maintained for at least 14 days 
after inoculation with the aliquot of disrupted MCS. Monolayers shall be 
subcultured at least once during the maintenance period. All but the 
last subculture shall result in a new monolayer of at least 75 cm\2\. 
The last subculture shall meet the minimum area requirement specified in 
Secs. 113.46 and 113.47.
    (3) Monolayers shall be examined regularly throughout the 14-day 
maintenance period for evidence of the presence of cytopathogenic 
agents. If evidence of a cytopathogenic agent is found, the MCS is 
unsatisfactory.
    (4) At the conclusion of the 14-day maintenance period, monolayers 
shall be tested for:
    (i) Cytopathogenic and/or hemadsorbing agents as prescribed in 
Sec. 113.46; and
    (ii) Extraneous viruses by the fluorescent antibody technique as 
prescribed in Sec. 113.47.
    (g) The karyology of cells lines used in the production of biologics 
shall be examined as follows. A minimum of 50 mitotic cells shall be 
examined at both the MCS and MCS+n. The modal number in the MCS+n shall 
not exceed plus or minus 15 percent of the modal number of the MCS. Any 
marker chromosomes present in the MCS shall persist at the MCS+n. If the 
modal number exceeds the limits and/or the marker chromosomes do not 
persist (through the MCS+n passage level), the cell line shall not be 
used for vaccine production.
    (h) If direct or indirect evidence exists that a cell line which is 
intended for use in the preparation of a vaccine may induce malignancies 
in the species for which the product is intended, that cell line shall 
be tested for tumorigenicity/oncogenicity by a method acceptable to 
APHIS.

[50 FR 442, Jan. 4, 1985; 50 FR 3316, Jan. 24, 1985, as amended at 56 FR 
66784, Dec. 26, 1991; 60 FR 24549, May 9, 1995]