[Code of Federal Regulations]
[Title 20, Volume 3]
[Revised as of April 1, 2003]
From the U.S. Government Printing Office via GPO Access
[CITE: 20CFR654.412]

[Page 454]
 
                      TITLE 20--EMPLOYEES' BENEFITS
 
 CHAPTER V--EMPLOYMENT AND TRAINING ADMINISTRATION, DEPARTMENT OF LABOR
 
PART 654--SPECIAL RESPONSIBILITIES OF THE EMPLOYMENT SERVICE SYSTEM--Table of Contents
 
               Subpart E--Housing for Agricultural Workers
 
Sec. 654.412  Bathing, laundry, and handwashing.

    (a) Bathing and handwashing facilities, supplied with hot and cold 
water under pressure, shall be provided for the use of all occupants. 
These facilities shall be clean and sanitary and located within 200 feet 
of each living unit.
    (b) There shall be a minimum of 1 showerhead per 15 persons. 
Showerheads shall be spaced at least 3 feet apart, with a minimum of 9 
square feet of floor space per unit. Adequate, dry dressing space shall 
be provided in common use facilities. Shower floors shall be constructed 
of nonabsorbent nonskid materials and sloped to properly constructed 
floor drains. Except in individual family units, separate shower 
facilities shall be provided each sex. When common use shower facilities 
for both sexes are in the same building they shall be separated by a 
solid nonabsorbent wall extending from the floor to ceiling, or roof, 
and shall be plainly designated ``men'' or ``women'' in English and in 
the native language of the persons expected to occupy the housing.
    (c) Lavatories or equivalent units shall be provided in a ratio of 1 
per 15 persons.
    (d) Laundry facilities, supplied with hot and cold water under 
pressure, shall be provided for the use of all occupants. Laundry trays 
or tubs shall be provided in the ratio of 1 per 25 persons. Mechanical 
washers may be provided in the ratio of 1 per 50 persons in lieu of 
laundry trays, although a minimum of 1 laundry tray per 100 persons 
shall be provided in addition to the mechanical washers.