Sec. 3280.5  Data plate.

    Each manufactured home shall bear a data plate affixed in a 
permanent manner near the main electrical panel or other readily 
accessible and visible location. Each data plate shall be made of 
material what will receive typed information as well as preprinted 
information, and which can be cleaned of ordinary smudges or household 
dirt without removing information contained on the data plate; or the 
data plate shall be covered in a permanent manner with materials that 
will make it possible to clean the data plate of ordinary dirt and 
smudges without obscuring the information. Each data plate shall contain 
not less than the following information:
    (a) The name and address of the manufacturing plant in which the 
manufactured home was manufactured.
    (b) The serial number and model designation of the unit, and the 
date the unit was manufactured.
    (c) The statement:

    This manufactured home is designed to comply with the Federal 
Manufactured Home Construction and Safety Standards in force at the time 
of manufacture.

    (d) A list of the certification label(s) number(s) that are affixed 
to each transportable manufactured section under Sec. 3280.8.
    (e) A list of major factory-installed equipment, including the 
manufacturer's name and the model designation of each appliance.
    (f) Reference to the roof load zone and wind load zone for which the 
home is designed and duplicates of the maps as set forth in 
Sec. 3280.305(c). This information may be combined with the heating/
cooling certificate and insulation zone map required by Secs. 3280.510 
and 3280.511. The Wind Zone Map on the Data Plate shall also contain the 
statement:

    This home has not been designed for the higher wind pressures and 
anchoring provisions required for ocean/coastal areas and should not be 
located within 1500' of the coastline in Wind Zones II and III, unless 
the home and its anchoring and foundation system have been designed for 
the increased requirements specified for Exposure D in ANSI/ASCE 7-88.

    (g) The statement:

    This home has--has not--(appropriate blank to be checked by 
manufacturer) been equipped with storm shutters or other protective 
coverings for windows and exterior door openings. For homes designed to 
be located in Wind Zones II and III, which have not been provided with 
shutters or equivalent covering devices, it is strongly recommended that 
the home be made ready to be equipped with these devices in accordance 
with the method recommended in the manufacturers printed instructions.

    (h) The statement: ``Design Approval by'', followed by the name of 
the agency that approved the design.