       Subpart B--Criteria for Reception Facilities: Oily Mixtures
 
Sec. 158.210  Ports and terminals loading crude oil.

    The reception facility for a crude oil loading port or terminal must 
have the capacity for receiving--
    (a) Oil residue from on-board fuel and lubricating oil processing in 
the amount of 10 metric tons (11 short tons);
    (b) Bilge water containing oily mixtures in the amount of 10 metric 
tons (11 short tons) or 2 metric tons (2.2 short tons) multiplied by the 
daily vessel average, whichever quantity is greater; and
    (c) Ballast water containing oily mixtures in the amount of 30% of 
the deadweight tonnage of the largest of the oceangoing tankers loading 
crude oil at the port or terminal that do not have clean ballast tanks 
(CBT), segregated ballast tanks (SBT), or crude oil washing (COW) 
meeting Part 157 of this subchapter, multiplied by one or the daily 
vessel average, whichever quantity is greater.

[CGD 78-035, 50 FR 36793, Sept. 9, 1985, as amended by CGD 85-010, 52 FR 
7764, Mar. 12, 1987; USCG-2000-7641, 66 FR 55574, Nov. 2, 2001]