[Code of Federal Regulations] [Title 33, Volume 2] [Revised as of July 1, 2003] From the U.S. Government Printing Office via GPO Access [CITE: 33CFR159.103] [Page 528] TITLE 33--NAVIGATION AND NAVIGABLE WATERS CHAPTER I--COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) PART 159--MARINE SANITATION DEVICES--Table of Contents Subpart C--Design, Construction, and Testing Sec. 159.103 Vibration test. The device, with liquid retention components, if any, filled with water to one-half of their volume, must be subjected to a sinusoidal vibration for a period of 12 hours, 4 hours in each of the x, y, and z planes, at the resonant frequency of the device (or at 55 cycles per second if there is no resonant frequency between 10 to 60 hertz) and with a peak amplitude of 0.019 to 0.021 inches.