Sec. 159.111  Pressure and vacuum pulse test.

    Liquid retention components of the device with manufacturer 
specified venting installed must be subjected to 50 fillings of water at 
a pressure head of 7 feet or the maximum pressure specified by the 
manufacturer for operation of the device, whichever is greater, and then 
emptied with a 45 gallon per minute or larger positive displacement pump 
that remains in operation 30 seconds after emptying the tank at the end 
of each cycle.