[Code of Federal Regulations]
[Title 33, Volume 2]
[Revised as of July 1, 2003]
From the U.S. Government Printing Office via GPO Access
[CITE: 33CFR159.115]

[Page 528]
 
                TITLE 33--NAVIGATION AND NAVIGABLE WATERS
 
   CHAPTER I--COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED)
 
PART 159--MARINE SANITATION DEVICES--Table of Contents
 
              Subpart C--Design, Construction, and Testing
 
Sec. 159.115  Temperature range test.

    (a) The device must be held at a temperature of 60 C or higher 
for a period of 16 hours.
    (b) The device must be held at a temperature of -40 C or less 
for a period of 16 hours following winterization in accordance with 
manufacturers' instructions.