                   TITLE 40--PROTECTION OF ENVIRONMENT
 
         CHAPTER I--ENVIRONMENTAL PROTECTION AGENCY (CONTINUED)
 
PART 205--TRANSPORTATION EQUIPMENT NOISE EMISSION CONTROLS--Table of Contents
 
                   Subpart B--Medium and Heavy Trucks
 
Sec. 205.54-2  Sound data acquisition system.

    (a) Systems employing tape recorders and graphic level recorders may 
be established as equivalent to a Type I--ANSI S1.4-1971 sound level 
meter for use in determining compliance with this regulation by meeting 
the requirements of this section (Sec. 205.54-2(b)). This sound data 
acquisition system qualification procedure is based primarily on ANSI 
S6.1-1973.
    (1) Performance requirements--(i) System frequency response. It is 
required that the overall steady-state frequency response of the data 
acquisition system shall be within the tolerances prescribed in Table 
205.1 when measured in accordance with section (2). The tolerances in 
Table 205.1 are applicable to either flat or A-weighted response. (See 
paragraph (a)(3)(iii) of this section.)
    (ii) Detector response. To ensure that a (true) rms indication is 
provided, the difference between the level indicated for a 1000 Hz 
sinusoidal signal equivalent to a sound level of 86 dB (rms) and the 
level indicated for an octave band of random noise of equal energy as 
the sinusoidal signal centered at 1000 Hz shall be no greater than 0.5 
dB. A true rms voltmeter shall be used to determine equivalence of two 
input signals.
    (iii) Indicating meter. If an indicating meter is used to obtain 
sound levels or band pressure levels, it must meet the requirements of 
paragraphs (a)(1)(ii) and (vi)(B) of this section and the following.

                    Table 205.1--System Response Data
------------------------------------------------------------------------
                       A-weighted            Tolerance (decibels)
  Freq. (hertz)    response (Re-1000 -----------------------------------
                        Hz, dB)            Plus--            Minus--
------------------------------------------------------------------------
         31.5              -39.4                1.5               1.5
         40.0              -34.6                1.5               1.5
         50.0              -30.2                1.0               1.0
         63.0              -26.2                1.0               1.0
         80.0              -22.5                1.0               1.0
        100.0              -19.1                1.0               1.0
        125.0              -16.1                1.0               1.0
        160.0              -13.4                1.0               1.0
        200.0              -10.9                1.0               1.0
        250.0               -8.6                1.0               1.0

[[Page 113]]


        315.0               -6.6                1.0               1.0
        400.0               -4.8                1.0               1.0
        500.0               -3.2                1.0               1.0
        630.0               -1.9                1.0               1.0
        800.0                -.8                1.0               1.0
      1,000.0                  0                1.0               1.0
      1,250.0                 .6                1.0               1.0
      1,600.0                1.0                1.0               1.0
      2,000.0                1.2                1.0               1.0
      2,500.0                1.3                1.0               1.0
      3,150.0                1.2                1.0               1.0
      4,000.0                1.0                1.0               1.0
      5,000.0                 .5                1.5               2.0
      6,300.0                -.1                1.5               2.0
      8,000.0               -1.1                1.5               3.0
     10,000.0               -2.5                2.0               4.0
     12,500.0               -4.3                3.0               6.0
------------------------------------------------------------------------

    (A) The scale shall be graduated in 1 dB steps.
    (B) No scale indication shall be more than 0.2 dB different from the 
true value of the signal when an input signal equivalent to 86 dB sound 
level indicates correctly.
    (C) Maximum indication for an input signal of 1000 Hz tone burst of 
0.2 sec duration shall be within the range of -2 to 0 dB with respect to 
the steady-state indication for a 1000 Hz tone equivalent to 86 dB sound 
level.
    (iv) Microphone. If microphone is used which has not been provided 
as a component of a precision sound level meter, it must be determined 
to meet the microphone characteristics described in IEC Publication 179, 
Precision Sound Level Meters.
    (v) Magnetic tape recorders. No requirements are described in this 
document pertaining to tape recorders, except for frequency response. 
Generally, recorders of adequate quality to provide the frequency 
response performance required will also meet other minimum requirements 
for distortion, signal-to-noise ratio, etc.
    (vi) Graphic level recorder dynamic response. When using a graphic 
level recorder, it is necessary to select pen response settings such 
that the readings obtained are statistically equivalent to those 
obtained by directly reading a meter which meets the ``fast'' dynamic 
requirement of a precision sound level meter indicating meter system for 
the range of vehicles to be tested. To ensure statistical equivalence, 
at least 30 comparative observations of real test data shall be made and 
the average of the absolute value of the differences observed shall be 
less than 0.5 dB. The settings described in this paragraph likely assure 
appropriate dynamic response; however, different settings may be 
selected on the basis of the above requirement.
    (A) Use a pen writing speed of nominally 60-100 dB/sec. If 
adjustable, low frequency response should be limited to about 20 Hz.
    (B) Indicated overshoot for a suddenly applied 1000 Hz sinusoidal 
signal equivalent to 86 dB sound level shall be no more than 1.1 dB and 
no less than 0.1 dB.
    (2) Frequency response qualification procedure. (i) Typical noise 
measurement and analysis configurations are shown in Figures 205.2 
through 205.4. The qualification procedure described herein duplicates 
these configurations, but with the microphone replaced by an electronic 
sinewave oscillator. Caution should be exercised when connecting an 
oscillator to the input of a sound level meter to ensure, perhaps by 
using a resistive voltage divider network, that the input is not 
overloaded (see Sec. 205.54-2(a)(2)(ii)).

[[Page 114]]

[GRAPHIC] [TIFF OMITTED] TC01FE92.053

    (ii) Calibrate the oscillator to be used by measuring its output 
relative to the voltage which is equivalent to 86 dB sound level at each 
of the 27 frequencies listed in Table 205.1 using an electronic 
voltmeter of known calibration. Record the result in voltage level in dB 
re voltage corresponding to 86 dB

[[Page 115]]

sound level at 1000 Hz. This will describe the frequency response 
characteristics of the oscillator.
    (iii) If a graphic level recorder is to be used, connect it to the 
oscillator output. If the oscillator and graphic level recorder can be 
synchronized, slowly sweep the frequency over the range of 31.5 to 
12,500 Hz, recording the oscillator output. If they cannot be 
synchronized, record oscillator output for signals at the 27 frequencies 
given in Table 205.1. The differences between the combined response thus 
obtained and the oscillator response obtained previously will describe 
the frequency response of the graphic level recorder.
    (iv) If visual observation of an indicating meter is to be used for 
obtaining data, the oscillator should be connected to the indicating 
meter input (such as the microphone input of a sound level meter) and 
the meter reading observed for a fixed oscillator output voltage setting 
for signals at the 27 frequencies given in Table 205.1.
    (v) To check a tape recorder, connect the instruments as shown in 
Figure 205.4. Using a 1000 Hz tone, adjust the oscillator output level 
to obtain a reading 15 dB below maximum record level. If the 
synchronized oscillator/graphic level recorder system is to be used for 
analysis, record an oscillator sweep over the range of 31.5 to 12,500 
Hz, using an appropriate tape recorder input attenuator setting. 
Alternatively, tape-record frequency tones at the 27 frequencies given 
in Table 205.1. Replay the tape recordings using the setup shown in 
Figure 205.3. Record the data on a graphic level recorder or through 
visual observation of the indicating meter. Subtract the oscillator 
frequency response in paragraph (b)(2) of this section from the response 
obtained through the record-playback sequence to obtain the record/
reproduce frequency response of the system except for the microphone.
    (vi) To obtain the overall system frequency response, add the 
manufacturer's microphone calibration data to the response just 
obtained. This may be the frequency response for the specific microphone 
to be used, including calibration tolerances. Alternatively, use the 
manufacturer's ``typical'' microphone response plus and minus the 
maximum deviation expected from ``typical'' including calibration 
tolerances. Use the microphone response curve which corresponds to the 
manner in which it is used in the field. It may be required to add a 
correction to the response curves provided to obtain field response; 
refer to the manufacturer's manual.
    (vii) Adjustment or repair of equipment may be required to obtain 
response within the requirements of paragraph (a) of this section. After 
any adjustments, the system shall be requalified according to paragraph 
(b) of this section.
    (3) General comments. (i) Calibrate tape recorders using the brand 
and type of magnetic tape used for actual data acquisition. Differences 
in tape can cause an appreciable variation in the recorder/reproduce 
frequency response characteristics of tape recorder.
    (ii) It shall be ensured that the instrumentation used will perform 
within specifications and applicable tolerances over the temperature, 
humidity, and other environmental variation ranges which may be 
encountered in vehicle noise measurement works.
    (iii) Qualification tests shall be performed using equipment 
(including cables) and recording and playback techniques identical with 
those used while recording vehicle noise. For example, if weighted sound 
level data are normally recorded use similar weighting and apply the 
tolerances of Table 205.1 to the weighting curve for comparison with 
record-playback curves. Precautions should also be taken to ensure that 
source and load impedances are appropriate to the device being tested. 
Other data acquisition systems may use any combination of microphones, 
sound level meters, amplifiers, tape recorders, graphic level recorders, 
or indicating meters. The same approach to qualifying such a system 
shall be taken as described in this document for the systems depicted in 
Figures 205.2, 205.3 and 205.4.
    (b) Systems other than those specified in Secs. 205.54-1(a) and 
205.54-2(a) may be used for establishing compliance with this 
regulation. In each case the system must yield sound levels which are 
equivalent to those produced by a sound level meter Type 1 ANSI S1.4-

[[Page 116]]

1971. The manufacturer bears the burden of demonstrating such 
equivalence.