[Code of Federal Regulations]
[Title 40, Volume 26]
[Revised as of July 1, 2003]
From the U.S. Government Printing Office via GPO Access
[CITE: 40CFR413.24]

[Page 210-211]
 
                TITLE 40-PROTECTION OF ENVIRONMENT
 
      CHAPTER I-ENVIRONMENTAL PROTECTION AGENCY (CONTINUED)
 
PART 413-ELECTROPLATING POINT SOURCE CATEGORY--Table of Contents
 
     Subpart B-Electroplating of Precious Metals Subcategory
 
Sec. 413.24  Pretreatment standards for existing sources.

    Except as provided in 40 CFR Sec.Sec. 403.7 and 
403.13, any existing source subject to this subpart which introduces 
pollutants into a publicly owned treatment works must comply with 40 CFR 
part 403 and achieve the following pretreatment standards for existing 
sources (PSES):
    (a) No user introducing wastewater pollutants into a publicly owned 
treatment works under the provisions of this subpart shall augment the 
use of process wastewater or otherwise dilute the wastewater as a 
partial or total substitute for adequate treatment to achieve compliance 
with this standard.
    (b) For a source discharging less than 38,000 liters (10,000 gal) 
per calendar day of electroplating process wastewater the following 
limitations shall apply:

  Subpart B-Precious Metals Facilities Discharging Less
           Than 38,000 Liters Per Day PSES Limitations (mg/l)
------------------------------------------------------------------------
                                                            Average of
                                                           daily values
                                                               for 4
     Pollutant or pollutant property        Maximum for     consecutive
                                             any 1 day      monitoring
                                                          days shall not
                                                              exceed
------------------------------------------------------------------------
CN, A...................................             5.0             2.7
Pb......................................              .6              .4
Cd......................................             1.2              .7
------------------------------------------------------------------------

    (c) For plants discharging 38,000 liters (10,000 gal) or more per 
calendar day of electroplating process wastewater the following 
limitations shall apply:

 Subpart B-Precious Metals Facilities Discharging 38,000
             Liters or More Per Day PSES Limitations (mg/l)
------------------------------------------------------------------------
                                                            Average of
                                                           daily values
                                                               for 4
     Pollutant or pollutant property        Maximum for     consecutive
                                             any 1 day      monitoring
                                                          days shall not
                                                              exceed
------------------------------------------------------------------------
Ag......................................             1.2             0.7
CN, T...................................             1.9             1.0
Cu......................................             4.5             2.7
Ni......................................             4.1             2.6
Cr......................................             7.0             4.0
Zn......................................             4.2             2.6
Pb......................................              .6              .4
Cd......................................             1.2              .7
Total metals............................            10.5             6.8
------------------------------------------------------------------------

    (d) Alternatively, the following mass-based standards are equivalent 
to and may apply in place of those limitations specified under paragraph 
(c) of this section upon prior agreement between a source subject to 
these standards and the publicly owned treatment works receiving such 
regulated wastes:

 Subpart B-Precious Metals Facilities Discharging 38,000
       Liters or More Per Day PSES Limitations (mg/sq m-Operation)
------------------------------------------------------------------------
                                                            Average of
                                                           daily values
                                                               for 4
     Pollutant or pollutant property        Maximum for     consecutive
                                             any 1 day      monitoring
                                                          days shall not
                                                              exceed
------------------------------------------------------------------------
Ag......................................              47              29
CN, T...................................              74              39
Cu......................................             176             105
Ni......................................             160             100
Cr......................................             273             156
Zn......................................             164             102

[[Page 211]]


Pb......................................              23              16
Cd......................................              47              29
Total metals............................             410             267
------------------------------------------------------------------------

    (e) For wastewater sources regulated under paragraph (c) of this 
section, the following optional control program may be elected by the 
source introducing treated process wastewater into a publicly owned 
treatment works with the concurrence of the control authority. These 
optional pollutant parameters are not eligible for allowance for removal 
achieved by the publicly owned treatment works under 40 CFR 403.7. In 
the absence of strong chelating agents, after reduction of hexavalent 
chromium wastes, and after neutralization using calcium oxide (or 
hydroxide) the following limitations shall apply:

 Subpart B-Precious Metals Facilities Discharging 38,000
             Liters or More Per Day PSES Limitations (mg/l)
------------------------------------------------------------------------
                                                            Average of
                                                           daily values
                                                               for 4
     Pollutant or pollutant property        Maximum for     consecutive
                                             any 1 day      monitoring
                                                          days shall not
                                                              exceed
------------------------------------------------------------------------
CN, T...................................             1.9             1.0
Pb......................................              .6              .4
Cd......................................             1.2              .7
TSS.....................................            20.0            13.4
pH......................................             \1\             \1\
------------------------------------------------------------------------
\1\ Within the range 7.5 to 10.0.

    (f) In addition to paragraphs (a) and (b) the following limitation 
shall apply for plants discharging less than 38,000 l (10,000 gal) per 
calendar day of electroplating process wastewater:

------------------------------------------------------------------------
        Pollutant or pollutant property           Maximum for any 1 day
------------------------------------------------------------------------
                                                   Milligrams per liter
                                                      [chyph](mg/l)

                                                ------------------------
TTO............................................                     4.57
------------------------------------------------------------------------

    (g) In addition to paragraphs (a), (c), (d), and (e) the following 
limitation shall apply for plants discharging 38,000 l (10,000 gal) or 
more per calendar day of electroplating process wastewater:

------------------------------------------------------------------------
        Pollutant or pollutant property           Maximum for any 1 day
------------------------------------------------------------------------
                                                   Milligrams per liter
                                                      [chyph](mg/l)

                                                ------------------------
TTO............................................                     2.13
------------------------------------------------------------------------

    (h) In addition to paragraphs (a), (b), (c), (d), (e), (f), and (g) 
the following shall apply: An existing source submitting a certification 
in lieu of monitoring pursuant to Sec. 413.03 of this 
regulation must implement the toxic organic management plan approved by 
the control authority.

(Secs. 301, 304, 306, 307, 308, and 501 of the Clean Water Act (the 
Federal Water Pollution Control Act Amendments of 1972, 33 U.S.C. 1251 
et. seq., as amended by the Clean Water Act of 1977, Pub. L. 95-217))

[46 FR 9467, Jan. 28, 1981, as amended at 48 FR 32484, July 15, 1983; 48 
FR 43681, Sept. 26, 1983]

Subpart C-Electroplating of Speciali[chyph]ty Metals 
Subcategory [Reserved]