[Code of Federal Regulations]
[Title 40, Volume 26]
[Revised as of July 1, 2003]
From the U.S. Government Printing Office via GPO Access
[CITE: 40CFR420.17]

[Page 398-399]
 
                TITLE 40-PROTECTION OF ENVIRONMENT
 
      CHAPTER I-ENVIRONMENTAL PROTECTION AGENCY (CONTINUED)
 
PART 420-IRON AND STEEL MANUFACTURING POINT SOURCE CATEGORY--Table of Contents
 
                 Subpart A-Cokemaking Subcategory
 
Sec. 420.17  Effluent limitations representing the degree of effluent reduction attainable by the application of the best conventional technology (BCT).

    Except as provided in 40 CFR 125.30 through 125.32, any existing 
point source subject to this subpart must achieve the following effluent 
limitations representing the degree of effluent reduction attainable by 
the application of the best conventional technology.
    (a) By-product cokemaking-iron and steel.

                                Subpart A
------------------------------------------------------------------------
                                                       BCT effluent
                                                       limitations
                                                ------------------------
                                                              Average of
        Pollutant or pollutant property                         daily
                                                   Maximum    values for
                                                  for any 1       30
                                                     day     consecutive
                                                                 days
------------------------------------------------------------------------
                                                    Kg/kkg (pounds per
                                                   1,000 lb) of product

                                                -------------
TSS............................................      0.253        0.131
O&G................................      0.0327       0.0109
pH.............................................  (\1\)        (\1\)
------------------------------------------------------------------------
\1\ Within the range of 6.0 to 9.0.

    (1) Increased loadings, not to exceed 11 percent of the above 
limitations, are allowed for by-product coke plants which have wet 
desulfurization systems but only to the extent such systems generate an 
increased effluent volume.
    (2) Increased loadings, not to exceed 27 percent of the above 
limitations, are allowed for by-product coke plants which include 
indirect ammonia recovery systems but only to the extent that such 
systems generate an increased effluent volume.
    (b) By-product cokemaking-merchant.

[[Page 399]]



                                Subpart A
------------------------------------------------------------------------
                                                       BCT effluent
                                                       limitations
                                                ------------------------
                                                              Average of
        Pollutant or pollutant property                         daily
                                                   Maximum    values for
                                                  for any 1       30
                                                     day     consecutive
                                                                 days
------------------------------------------------------------------------
                                                    Kg/kkg (pounds per
                                                   1,000 lb) of product

                                                -------------
TSS............................................      0.270        0.140
O&G................................      0.0348       0.0116
pH.............................................  (\1\)        (\1\)
------------------------------------------------------------------------
\1\ Within the range of 6.0 to 9.0.

    (1) Increased loadings, not to exceed 10 percent of the above 
limitations, are allowed for by-product coke plants which have wet 
desulfurization systems but only to the extent such systems generate an 
increased effluent volume.
    (2) Increased loadings, not to exceed 25 percent of the above 
limitations, are allowed for by-product coke plants which include 
indirect ammonia recovery systems but only to the extent that such 
systems generate an increased effluent volume.
    (c) Cokemaking-non-recovery. Except as provided in 40 CFR 
125.30 through 125.32, any existing point source subject to this segment 
must achieve the following effluent limitations representing the degree 
of effluent reduction attainable by the application of the best 
conventional pollutant control technology (BCT): There shall be no 
discharge of process wastewater pollutants to waters of the U.S.

[47 FR 23284, May 27, 1982, as amended at 67 FR 64264, Oct. 17, 2002]