[Code of Federal Regulations] [Title 40, Volume 27] [Revised as ofJuly 1, 2003] From the U.S. Government Printing Office via GPO Access [CITE: 40CFR455.23] [Page 473] TITLE 40--PROTECTION OF ENVIRONMENT CHAPTER I--ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) PART 455--PESTICIDE CHEMICALS--Table of Contents Subpart A--Organic Pesticide Chemicals Manufacturing Subcategory Sec. 455.23 Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best conventional pollutant control technology (BCT). Except as provided in 40 CFR 125.30 through 125.32, any existing point source subject to this subpart must achieve the effluent limitations representing the degree of effluent reduction attainable by the application of the best conventional pollutant control technology: The limitations for BOD, TSS and pH are the same as those specified in 40 CFR 455.22. BCT Effluent Limitations Effluent Limitations ------------------------------------------------------------------------ Average Maximum of daily for any values Pollutant or pollutant property one shall day** not exceed** ------------------------------------------------------------------------ BOD5................................................. 7.400 1.6000 TSS.................................................. 6.100 1.8000 pH................................................... * * ------------------------------------------------------------------------ * Within the range 6.0 to 9.0 ** Metric units: Kilogram pollutant/1,000 kg of total organic active ingredients. English units: Pound pollutant/1,000 lb of total organic active ingredients [58 FR 50689, Sept. 28, 1993]