[Code of Federal Regulations]
[Title 40, Volume 5]
[Revised as of July 1, 2003]
From the U.S. Government Printing Office via GPO Access
[CITE: 40CFR53.3]
[Page 8-9]
TITLE 40--PROTECTION OF ENVIRONMENT
CHAPTER I--ENVIRONMENTAL PROTECTION AGENCY (CONTINUED)
PART 53--AMBIENT AIR MONITORING REFERENCE AND EQUIVALENT METHODS--Table of Contents
Subpart A--General Provisions
Sec. 53.3 General requirements for an equivalent method determination.
(a) Manual methods. A manual equivalent method must have been shown
in accordance with this part to satisfy the applicable requirements
specified in subpart C of this part. In addition, PM10 or
PM2.5 samplers associated with manual equivalent methods for
PM10 or PM2.5 must have been shown in accordance
with this part to satisfy the following additional requirements:
(1) A PM10 sampler associated with a manual method for
PM10 must satisfy the requirements of subpart D of this part.
(2) A PM2.5 Class I equivalent method sampler must
satisfy all requirements of subparts C and E of this part, which include
appropriate demonstration that each and every deviation or modification
from the reference method sampler specifications does not significantly
alter the performance of the sampler.
(3) A PM2.5 Class II equivalent method sampler must
satisfy the applicable requirements of subparts C, E, and F of this
part.
(4) Requirements for PM2.5 Class III equivalent method
samplers are not provided in this part because of the wide range of non-
filter-based measurement technologies that could be applied and the
likelihood that these requirements will have to be specifically adapted
for each such type of technology. Specific requirements will be
developed as needed and may include selected requirements from subparts
C, E, or F of this part or other requirements not contained in this
part.
(5) All designated equivalent methods for PM2.5 must be
manufactured in an ISO 9001-registered facility, as defined in Sec. 53.1
and as set forth in Sec. 53.51, and the Product Manufacturing Checklist
set forth in subpart E of this part must be completed by an ISO-
certified auditor, as defined in Sec. 53.1, and submitted to EPA
annually to retain a PM2.5 equivalent method designation.
(b) Automated methods. (1) Automated equivalent methods for
pollutants other than PM2.5 or PM10 must have been
shown in accordance with this part to satisfy the requirements specified
in subparts B and C of this part.
(2) Automated equivalent methods for PM10 must have been
shown in accordance with this part to satisfy the requirements of
subparts C and D of this part.
(3) Requirements for PM2.5 Class III automated equivalent
methods for
[[Page 9]]
PM2.5 are not provided in this part because of the wide range
of non-filter-based measurement technologies that could be applied and
the likelihood that these requirements will have to be specifically
adapted for each such type of technology. Specific requirements will be
developed as needed and may include selected requirements from subparts
C, E, or F of this part or other requirements not contained in this
part.
(4) All designated equivalent methods for PM2.5 must be
manufactured in an ISO 9001-registered facility, as set forth in subpart
E of this part, and the Product Manufacturing Checklist set forth in
subpart E of this part must be completed by an ISO-certified auditor and
submitted to EPA annually to retain a PM2.5 equivalent method
designation.
[62 FR 38784, July 18, 1997; 63 FR 7714, Feb. 17, 1998]