[Code of Federal Regulations]
[Title 40, Volume 5]
[Revised as of July 1, 2003]
From the U.S. Government Printing Office via GPO Access
[CITE: 40CFR53.9]
[Page 12-13]
TITLE 40--PROTECTION OF ENVIRONMENT
CHAPTER I--ENVIRONMENTAL PROTECTION AGENCY (CONTINUED)
PART 53--AMBIENT AIR MONITORING REFERENCE AND EQUIVALENT METHODS--Table of Contents
Subpart A--General Provisions
Sec. 53.9 Conditions of designation.
Designation of a candidate method as a reference method or
equivalent method shall be conditioned to the applicant's compliance
with the following requirements. Failure to comply with any of the
requirements shall constitute a ground for cancellation of the
designation in accordance with Sec. 53.11.
[[Page 13]]
(a) Any method offered for sale as a reference or equivalent method
shall be accompanied by a copy of the manual referred to in
Sec. 53.4(b)(3) when delivered to any ultimate purchaser.
(b) Any method offered for sale as a reference or equivalent method
shall generate no unreasonable hazard to operators or to the environment
during normal use or when malfunctioning.
(c) Any analyzer, PM10 sampler, or PM2.5
sampler offered for sale as part of a reference or equivalent method
shall function within the limits of the performance specifications
referred to in Sec. 53.20(a), Sec. 53.30(a), Sec. 53.50, or Sec. 53.60,
as applicable, for at least 1 year after delivery and acceptance when
maintained and operated in accordance with the manual referred to in
Sec. 53.4(b)(3).
(d) Any analyzer, PM10 sampler, or PM2.5
sampler offered for sale as a reference or equivalent method shall bear
a prominent, permanently affixed label or sticker indicating that the
analyzer or sampler has been designated by EPA as a reference method or
as an equivalent method (as applicable) in accordance with this part and
displaying any designated method identification number that may be
assigned by EPA.
(e) If an analyzer is offered for sale as a reference or equivalent
method and has one or more selectable ranges, the label or sticker
required by paragraph (d) of this section shall be placed in close
proximity to the range selector and shall indicate clearly which range
or ranges have been designated as parts of the reference or equivalent
method.
(f) An applicant who offers analyzers, PM10 samplers, or
PM2.5 samplers for sale as reference or equivalent methods
shall maintain an accurate and current list of the names and mailing
addresses of all ultimate purchasers of such analyzers or samplers. For
a period of 7 years after publication of the reference or equivalent
method designation applicable to such an analyzer or sampler, the
applicant shall notify all ultimate purchasers of the analyzer or
PM2.5 or PM10 sampler within 30 days if the
designation has been canceled in accordance with Sec. 53.11 or
Sec. 53.16 or if adjustment of the analyzer or sampler is necessary
under Sec. 53.11(b).
(g) If an applicant modifies an analyzer, PM10 sampler,
or PM2.5 sampler that has been designated as a reference or
equivalent method, the applicant shall not sell the modified analyzer or
sampler as a reference or equivalent method nor attach a label or
sticker to the modified analyzer or sampler under paragraph (d) or (e)
of this section until the applicant has received notice under
Sec. 53.14(c) that the existing designation or a new designation will
apply to the modified analyzer, PM10 sampler, or
PM2.5 sampler or has applied for and received notice under
Sec. 53.8(b) of a new reference or equivalent method determination for
the modified analyzer or sampler.
(h) An applicant who has offered PM2.5 samplers or
analyzers for sale as part of a reference or equivalent method may
continue to do so only so long as the facility in which the samplers or
analyzers are manufactured continues to be an ISO 9001-registered
facility, as set forth in subpart E of this part. In the event that the
ISO 9001 registration for the facility is withdrawn, suspended, or
otherwise becomes inapplicable, either permanently or for some specified
time interval, such that the facility is no longer an ISO 9001-
registered facility, the applicant shall notify EPA within 30 days of
the date the facility becomes other than an ISO 9001-registered
facility, and upon such notification, EPA shall issue a preliminary
finding and notification of possible cancellation of the reference or
equivalent method designation under Sec. 53.11.
(i) An applicant who has offered PM2.5 samplers or
analyzers for sale as part of a reference or equivalent method may
continue to do so only so long as updates of the Product Manufacturing
Checklist set forth in subpart E of this part are submitted annually. In
the event that an annual Checklist update is not received by EPA within
12 months of the date of the last such submitted Checklist or Checklist
update, EPA shall notify the applicant within 30 days that the Checklist
update has not been received and shall, within 30 days from the issuance
of such notification, issue a preliminary finding and notification of
possible cancellation of the reference or equivalent method designation
under Sec. 53.11.
[[Page 14]]