Sec. 75.14  Specific provisions for monitoring opacity.

    (a) Coal-fired units and oil-fired units. The owner or operator 
shall meet the general operating provisions in Sec. 75.10 of this part 
for a continuous opacity monitoring system for each affected coal-fired 
or oil-fired unit, except as provided in paragraphs (b), (c), and (d) of 
this section and in Sec. 75.18. Each continuous opacity monitoring 
system shall meet the design, installation, equipment, and performance 
specifications in Performance Specification 1 in appendix B to part 60 
of this chapter. Any continuous opacity monitoring system previously 
certified to meet Performance Specification 1 shall be deemed certified 
for the purposes of this part.
    (b) Unit with wet flue gas pollution control system. If the owner or 
operator can demonstrate that condensed water is present in the exhaust 
flue gas stream and would impede the accuracy of opacity measurements, 
then the owner or operator of an affected unit equipped with a wet flue 
gas pollution control system for SO2 emissions or 
particulates is exempt from the opacity monitoring requirements of this 
part.
    (c) Gas-fired units. The owner or operator of an affected unit that 
qualifies as gas-fired, as defined in Sec. 72.2 of this chapter, based 
on information submitted by the designated representative in the 
monitoring plan is exempt from the opacity monitoring requirements of 
this part. Whenever a unit previously categorized as a gas-fired unit is 
recategorized as another type of unit by changing its fuel mix, the 
owner or operator shall install, operate, and certify a continuous 
opacity monitoring system as required by paragraph (a) of this section 
by December 31 of the following calendar year.
    (d) Diesel-fired units and dual-fuel reciprocating engine units. The 
owner or operator of an affected diesel-fired unit or a dual-fuel 
reciprocating engine unit is exempt from the opacity monitoring 
requirements of this part.

[58 FR 3701, Jan. 11, 1993, as amended at 61 FR 25581, May 22, 1996]