[Code of Federal Regulations]
[Title 40, Volume 14]
[Revised as of July 1, 2003]
From the U.S. Government Printing Office via GPO Access
[CITE: 40CFR75.14]
[Page 220]
TITLE 40--PROTECTION OF ENVIRONMENT
CHAPTER I--ENVIRONMENTAL PROTECTION AGENCY (CONTINUED)
PART 75--CONTINUOUS EMISSION MONITORING--Table of Contents
Subpart B--Monitoring Provisions
Sec. 75.14 Specific provisions for monitoring opacity.
(a) Coal-fired units and oil-fired units. The owner or operator
shall meet the general operating provisions in Sec. 75.10 of this part
for a continuous opacity monitoring system for each affected coal-fired
or oil-fired unit, except as provided in paragraphs (b), (c), and (d) of
this section and in Sec. 75.18. Each continuous opacity monitoring
system shall meet the design, installation, equipment, and performance
specifications in Performance Specification 1 in appendix B to part 60
of this chapter. Any continuous opacity monitoring system previously
certified to meet Performance Specification 1 shall be deemed certified
for the purposes of this part.
(b) Unit with wet flue gas pollution control system. If the owner or
operator can demonstrate that condensed water is present in the exhaust
flue gas stream and would impede the accuracy of opacity measurements,
then the owner or operator of an affected unit equipped with a wet flue
gas pollution control system for SO2 emissions or
particulates is exempt from the opacity monitoring requirements of this
part.
(c) Gas-fired units. The owner or operator of an affected unit that
qualifies as gas-fired, as defined in Sec. 72.2 of this chapter, based
on information submitted by the designated representative in the
monitoring plan is exempt from the opacity monitoring requirements of
this part. Whenever a unit previously categorized as a gas-fired unit is
recategorized as another type of unit by changing its fuel mix, the
owner or operator shall install, operate, and certify a continuous
opacity monitoring system as required by paragraph (a) of this section
by December 31 of the following calendar year.
(d) Diesel-fired units and dual-fuel reciprocating engine units. The
owner or operator of an affected diesel-fired unit or a dual-fuel
reciprocating engine unit is exempt from the opacity monitoring
requirements of this part.
[58 FR 3701, Jan. 11, 1993, as amended at 61 FR 25581, May 22, 1996]