[Code of Federal Regulations]
[Title 40, Volume 14]
[Revised as of July 1, 2003]
From the U.S. Government Printing Office via GPO Access
[CITE: 40CFR75.32]
[Page 263-264]
TITLE 40--PROTECTION OF ENVIRONMENT
CHAPTER I--ENVIRONMENTAL PROTECTION AGENCY (CONTINUED)
PART 75--CONTINUOUS EMISSION MONITORING--Table of Contents
Subpart D--Missing Data Substitution Procedures
Sec. 75.32 Determination of monitor data availability for standard missing
data procedures.
(a) Following initial certification of the required SO2,
CO2, O2 or moisture monitoring system(s) at a
particular unit or stack location (i.e., the date and time at which
quality-assured data begins to be recorded by CEMS(s) at that location),
the owner or operator shall begin calculating the percent monitor data
availability as described in paragraph (a)(1) of this section, and
shall, upon completion of the first 720 quality-assured monitor
operating hours, record, by means of the automated data acquisition and
handling system, the percent monitor data availability for each
monitored parameter. Similarly, following initial certification of the
required NOX-diluent, NOX concentration, or flow
monitoring system(s) at a unit or stack location, the owner or operator
shall begin calculating the percent monitor data availability as
described in paragraph (a)(1) of this section, and shall, upon
completion of the first 2,160 quality-assured monitor operating hours,
record, by means of the automated data acquisition and handling system,
the percent monitor data availability for each monitored parameter.
Notwithstanding these requirements, if three years (26,280 clock hours)
have elapsed since the date and hour of initial certification and fewer
than 720 (or 2,160, as applicable) quality-assured monitor operating
hours have been recorded, the owner or operator shall begin recording
the percent monitor data availability. The percent monitor data
availability shall be calculated for each monitored parameter at each
unit or stack location, as follows:
(1) Prior to completion of 8,760 unit or stack operating hours
following initial certification, the owner or operator shall, for the
purpose of applying the standard missing data procedures of Sec. 75.33,
use Equation 8 to calculate, hourly, percent monitor data availability.
[GRAPHIC] [TIFF OMITTED] TC13NO91.041
(2) Upon completion of 8,760 unit (or stack) operating hours
following initial certification and thereafter, the owner or operator
shall, for the purpose of applying the standard missing data procedures
of Sec. 75.33, use Equation 9 to calculate hourly, percent monitor data
availability. Notwithstanding this requirement, if three years (26,280
clock
[[Page 264]]
hours) have elapsed since initial certification and fewer than 8,760
unit or stack operating hours have been accumulated, the owner or
operator shall begin using a modified version of Equation 9, as
described in paragraph (a)(3) of this section.
[GRAPHIC] [TIFF OMITTED] TC13NO91.042
(3) When calculating percent monitor data availability using
Equation 8 or 9, the owner or operator shall include all unit operating
hours, and all monitor operating hours for which quality-assured data
were recorded by a certified primary monitor; a certified redundant or
non-redundant backup monitor or a reference method for that unit; or by
an approved alternative monitoring system under subpart E of this part.
No hours from more than three years (26,280 clock hours) earlier shall
be used in Equation 9. For a unit that has accumulated fewer than 8,760
unit operating hours in the previous three years (26,280 clock hours),
replace the words ``during previous 8,760 unit operating hours'' in the
numerator of Equation 9 with ``in the previous three years'' and replace
``8,760'' in the denominator of Equation 9 with ``total unit operating
hours in the previous three years.'' The owner or operator of a unit
with an SO2 monitoring system shall, when SO2
emissions are determined in accordance with Sec. 75.11(e)(1) or (e)(2),
exclude hours in which a unit combusts only gaseous fuel from
calculations of percent monitor data availability for SO2
pollutant concentration monitors, as provided in Sec. 75.30(d).
(b) The monitor data availability need not be calculated during the
missing data period. The owner or operator shall record the percent
monitor data availability for the last hour of each missing data period
as the monitor availability used to implement the missing data
substitution procedures.
[58 FR 3701, Jan. 11, 1993, as amended at 60 FR 26529, 26567, May 17,
1995; 61 FR 59160, Nov. 20, 1996; 64 FR 28602, May 26, 1999; 67 FR
40434, June 12, 2002]