[Code of Federal Regulations]
[Title 40, Volume 14]
[Revised as of July 1, 2003]
From the U.S. Government Printing Office via GPO Access
[CITE: 40CFR75.37]

[Page 274-275]
 
                   TITLE 40--PROTECTION OF ENVIRONMENT
 
         CHAPTER I--ENVIRONMENTAL PROTECTION AGENCY (CONTINUED)
 
PART 75--CONTINUOUS EMISSION MONITORING--Table of Contents
 
             Subpart D--Missing Data Substitution Procedures
 
Sec. 75.37  Missing data procedures for moisture.

    (a) The owner or operator of a unit with a continuous moisture 
monitoring system shall substitute for missing moisture data using the 
procedures of this section.
    (b) Where no prior quality-assured moisture data exist, substitute 
the minimum potential moisture percentage, from section 2.1.5 of 
appendix A to this part, except when Equation 19-3, 19-4 or 19-8 in 
Method 19 in appendix A to part 60 of this chapter is used to determine 
NOX emission rate. If Equation 19-3, 19-4 or 19-8 in Method 
19 in appendix A to part 60 of this chapter is used to determine 
NOX emission rate, substitute the maximum potential moisture 
percentage, as specified in section 2.1.6 of appendix A to this part.
    (c) During the first 720 quality-assured monitor operating hours 
following initial certification at a particular unit or stack location 
(i.e., the date and time at which quality-assured data begins to be 
recorded by a moisture monitoring system at that location), the owner or 
operator shall provide substitute data for moisture according to 
Sec. 75.31(b).
    (d) Upon completion of the first 720 quality-assured monitor 
operating hours following initial certification, the owner or operator 
shall provide substitute data for moisture as follows:
    (1) Unless Equation 19-3, 19-4 or 19-8 in Method 19 in appendix A to 
part 60 of this chapter is used to determine NOX emission 
rate, follow the missing data procedures in Sec. 75.33(b), except that 
the term ``moisture percentage'' shall apply rather than 
``SO2 concentration;'' the term ``moisture monitoring 
system'' shall apply rather than the term ``SO2 pollutant 
concentration monitor;'' the term ``substitute the lesser of'' shall 
apply rather than ``substitute the greater of;'' the terms ``minimum 
hourly moisture percentage'' and ``minimum potential moisture 
percentage, as determined under section 2.1.5 of appendix A to this 
part''

[[Page 275]]

shall apply rather than, respectively, the terms ``maximum hourly 
SO2 concentration'' and ``maximum potential SO2 
concentration, as determined under section 2.1.1.1 of appendix A to this 
part;'' and the terms ``10th percentile'' and ``5th percentile'' shall 
apply rather than, respectively, the terms ``90th percentile'' and 
``95th percentile'' (see Table 1 of Sec. 75.33).
    (2) When Equation 19-3, 19-4 or 19-8 in Method 19 in appendix A to 
part 60 of this chapter is used to determine NOX emission 
rate:
    (i) Provided that none of the following equations is used to 
determine SO2 emissions, CO2 emissions or heat 
input: Equation F-2, F-14b, F-16, F-17, or F-18 in appendix F to this 
part, or Equation 19-5 or 19-9 in Method 19 in appendix A to part 60 of 
this chapter, use the missing data procedures in Sec. 75.33(b), except 
that the term ``moisture percentage'' shall apply rather than 
``SO2 concentration,'' the term ``moisture monitoring 
system'' shall apply rather than ``SO2 pollutant 
concentration monitor,'' and the term ``maximum potential moisture 
percentage, as defined in section 2.1.6 of appendix A to this part'' 
shall apply, rather than ``maximum potential SO2 
concentration;'' or
    (ii) If any of the following equations is used to determine 
SO2 emissions, CO2 emissions or heat input: 
Equation F-2, F-14b, F-16, F-17, or F-18 in appendix F to this part, or 
Equation 19-5 or 19-9 in Method 19 in appendix A to part 60 of this 
chapter, the owner or operator shall petition the Administrator under 
Sec. 75.66(l) for permission to use an alternative moisture missing data 
procedure.