[Code of Federal Regulations]
[Title 40, Volume 14]
[Revised as of July 1, 2003]
From the U.S. Government Printing Office via GPO Access
[CITE: 40CFR75.59]

[Page 296-307]
 
                   TITLE 40--PROTECTION OF ENVIRONMENT
 
         CHAPTER I--ENVIRONMENTAL PROTECTION AGENCY (CONTINUED)
 
PART 75--CONTINUOUS EMISSION MONITORING--Table of Contents
 
                  Subpart F--Recordkeeping Requirements
 
Sec. 75.59  Certification, quality assurance, and quality control record 
provisions.

    The owner or operator shall meet all of the applicable recordkeeping 
requirements of this section.
    (a) Continuous emission or opacity monitoring systems. The owner or 
operator shall record the applicable information in this section for 
each certified monitor or certified monitoring system (including 
certified backup monitors) measuring and recording emissions or flow 
from an affected unit.
    (1) For each SO2 or NOX pollutant 
concentration monitor, flow monitor, CO2 pollutant 
concentration monitor (including O2 monitors used to 
determine CO2 emissions), or diluent gas monitor (including 
wet- and dry-basis O2 monitors used to determine percent 
moisture), the owner or operator shall record the following for all 
daily and 7-day calibration error tests and all off-line calibration 
demonstrations, including any follow-up tests after corrective action:
    (i) Component-system identification code;
    (ii) Instrument span and span scale;
    (iii) Date and hour;
    (iv) Reference value (i.e., calibration gas concentration or 
reference signal value, in ppm or other appropriate units);
    (v) Observed value (monitor response during calibration, in ppm or 
other appropriate units);
    (vi) Percent calibration error (rounded to the nearest tenth of a 
percent) (flag if using alternative performance specification for low 
emitters or differential pressure flow monitors);
    (vii) Reference signal or calibration gas level;
    (viii) Test number and reason for test;

[[Page 297]]

    (ix) For 7-day calibration tests for certification or 
recertification, a certification from the cylinder gas vendor or CEMS 
vendor that calibration gas, as defined in Sec. 72.2 of this chapter and 
appendix A to this part, was used to conduct calibration error testing;
    (x) Description of any adjustments, corrective actions, or 
maintenance prior to a passed test or following a failed test; and
    (xi) For the qualifying test for off-line calibration, the owner or 
operator shall indicate whether the unit is off-line or on-line.
    (2) For each flow monitor, the owner or operator shall record the 
following for all daily interference checks, including any follow-up 
tests after corrective action.
    (i) Component-system identification code;
    (ii) Date and hour;
    (iii) Code indicating whether monitor passes or fails the 
interference check; and
    (iv) Description of any adjustments, corrective actions, or 
maintenance prior to a passed test or following a failed test.
    (3) For each SO2 or NOX pollutant 
concentration monitor, CO2 pollutant concentration monitor 
(including O2 monitors used to determine CO2 
emissions), or diluent gas monitor (including wet- and dry-basis 
O2 monitors used to determine percent moisture), the owner or 
operator shall record the following for the initial and all subsequent 
linearity check(s), including any follow-up tests after corrective 
action.
    (i) Component-system identification code;
    (ii) Instrument span and span scale;
    (iii) Calibration gas level;
    (iv) Date and time (hour and minute) of each gas injection at each 
calibration gas level;
    (v) Reference value (i.e., reference gas concentration for each gas 
injection at each calibration gas level, in ppm or other appropriate 
units);
    (vi) Observed value (monitor response to each reference gas 
injection at each calibration gas level, in ppm or other appropriate 
units);
    (vii) Mean of reference values and mean of measured values at each 
calibration gas level;
    (viii) Linearity error at each of the reference gas concentrations 
(rounded to nearest tenth of a percent) (flag if using alternative 
performance specification);
    (ix) Test number and reason for test (flag if aborted test); and
    (x) Description of any adjustments, corrective action, or 
maintenance prior to a passed test or following a failed test.
    (4) For each differential pressure type flow monitor, the owner or 
operator shall record items in paragraphs (a)(4) (i) through (v) of this 
section, for all quarterly leak checks, including any follow-up tests 
after corrective action. For each flow monitor, the owner or operator 
shall record items in paragraphs (a)(4) (vi) and (vii) for all flow-to-
load ratio and gross heat rate tests:
    (i) Component-system identification code.
    (ii) Date and hour.
    (iii) Reason for test.
    (iv) Code indicating whether monitor passes or fails the quarterly 
leak check.
    (v) Description of any adjustments, corrective actions, or 
maintenance prior to a passed test or following a failed test.
    (vi) Test data from the flow-to-load ratio or gross heat rate (GHR) 
evaluation, including:
    (A) Monitoring system identification code;
    (B) Calendar year and quarter;
    (C) Indication of whether the test is a flow-to-load ratio or gross 
heat rate evaluation;
    (D) Indication of whether bias adjusted flow rates were used;
    (E) Average absolute percent difference between reference ratio (or 
GHR) and hourly ratios (or GHR values);
    (F) Test result;
    (G) Number of hours used in final quarterly average;
    (H) Number of hours exempted for use of a different fuel type;
    (I) Number of hours exempted for load ramping up or down;
    (J) Number of hours exempted for scrubber bypass;
    (K) Number of hours exempted for hours preceding a normal-load flow 
RATA;

[[Page 298]]

    (L) Number of hours exempted for hours preceding a successful 
diagnostic test, following a documented monitor repair or major 
component replacement; and
    (M) Number of hours excluded for flue gases discharging 
simultaneously thorough a main stack and a bypass stack.
    (vii) Reference data for the flow-to-load ratio or gross heat rate 
evaluation, including (as applicable):
    (A) Reference flow RATA end date and time;
    (B) Test number of the reference RATA;
    (C) Reference RATA load and load level;
    (D) Average reference method flow rate during reference flow RATA;
    (E) Reference flow/load ratio;
    (F) Average reference method diluent gas concentration during flow 
RATA and diluent gas units of measure;
    (G) Fuel specific Fd -or Fc-factor during flow 
RATA and F-factor units of measure;
    (H) Reference gross heat rate value;
    (I) Monitoring system identification code;
    (J) Average hourly heat input rate during RATA;
    (K) Average gross unit load; and
    (L) Operating load level.
    (5) For each SO2 pollutant concentration monitor, flow 
monitor, each CO2 pollutant concentration monitor (including 
any O2 concentration monitor used to determine CO2 
mass emissions or heat input), each NOX-diluent continuous 
emission monitoring system, each SO2-diluent continuous 
emission monitoring system, each NOX concentration monitoring 
system, each diluent gas (O2 or CO2) monitor used 
to determine heat input, each moisture monitoring system, and each 
approved alternative monitoring system, the owner or operator shall 
record the following information for the initial and all subsequent 
relative accuracy test audits:
    (i) Reference method(s) used.
    (ii) Individual test run data from the relative accuracy test audit 
for the SO2 concentration monitor, flow monitor, 
CO2 pollutant concentration monitor, NOX-diluent 
continuous emission monitoring system, SO2-diluent continuous 
emission monitoring system, diluent gas (O2 or 
CO2) monitor used to determine heat input, NOX 
concentration monitoring system, moisture monitoring system, or approved 
alternative monitoring system, including:
    (A) Date, hour, and minute of beginning of test run;
    (B) Date, hour, and minute of end of test run;
    (C) Monitoring system identification code;
    (D) Test number and reason for test;
    (E) Operating level (low, mid, high, or normal, as appropriate) and 
number of operating levels comprising test;
    (F) Normal load (or operating level) indicator for flow RATAs 
(except for peaking units);
    (G) Units of measure;
    (H) Run number;
    (I) Run value from CEMS being tested, in the appropriate units of 
measure;
    (J) Run value from reference method, in the appropriate units of 
measure;
    (K) Flag value (0, 1, or 9, as appropriate) indicating whether run 
has been used in calculating relative accuracy and bias values or 
whether the test was aborted prior to completion;
    (L) Average gross unit load, expressed as a total gross unit load, 
rounded to the nearest MWe, or as steam load, rounded to the nearest 
thousand lb/hr), except for units that do not produce electrical or 
thermal output; and
    (M) Flag to indicate whether an alternative performance 
specification has been used.
    (iii) Calculations and tabulated results, as follows:
    (A) Arithmetic mean of the monitoring system measurement values, of 
the reference method values, and of their differences, as specified in 
Equation A-7 in appendix A to this part;
    (B) Standard deviation, as specified in Equation A-8 in appendix A 
to this part;
    (C) Confidence coefficient, as specified in Equation A-9 in appendix 
A to this part;
    (D) Statistical ``t'' value used in calculations;
    (E) Relative accuracy test results, as specified in Equation A-10 in 
appendix A to this part. For multi-level flow monitor tests the relative 
accuracy

[[Page 299]]

test results shall be recorded at each load (or operating) level tested. 
Each load (or operating) level shall be expressed as a total gross unit 
load, rounded to the nearest MWe, or as steam load, rounded to the 
nearest thousand lb/hr, or as otherwise specified by the Administrator, 
for units that do not produce electrical or thermal output;
    (F) Bias test results as specified in section 7.6.4 in appendix A to 
this part; and
    (G) Bias adjustment factor from Equation A-12 in appendix A to this 
part for any monitoring system that failed the bias test (except as 
otherwise provided in section 7.6.5 of appendix A to this part) and 
1.000 for any monitoring system that passed the bias test.
    (iv) Description of any adjustment, corrective action, or 
maintenance prior to a passed test or following a failed or aborted 
test.
    (v) F-factor value(s) used to convert NOX pollutant 
concentration and diluent gas (O2 or CO2) 
concentration measurements into NOX emission rates (in lb/
mmBtu), heat input or CO2 emissions.
    (vi) For flow monitors, the equation used to linearize the flow 
monitor and the numerical values of the polynomial coefficients or K 
factor(s) of that equation.
    (vii) For moisture monitoring systems, the coefficient or ``K'' 
factor or other mathematical algorithm used to adjust the monitoring 
system with respect to the reference method.
    (6) For each SO2, NOX, or CO2 
pollutant concentration monitor, NOX-diluent continuous 
emission monitoring system, SO2-diluent continuous emission 
monitoring system, NOX concentration monitoring system, or 
diluent gas (O2 or CO2) monitor used to determine 
heat input, the owner or operator shall record the following information 
for the cycle time test:
    (i) Component-system identification code;
    (ii) Date;
    (iii) Start and end times;
    (iv) Upscale and downscale cycle times for each component;
    (v) Stable start monitor value;
    (vi) Stable end monitor value;
    (vii) Reference value of calibration gas(es);
    (viii) Calibration gas level;
    (ix) Cycle time result for the entire system;
    (x) Reason for test; and
    (xi) Test number.
    (7) In addition to the information in paragraph (a)(5) of this 
section, the owner or operator shall record, for each relative accuracy 
test audit, supporting information sufficient to substantiate compliance 
with all applicable sections and appendices in this part. Unless 
otherwise specified in this part or in an applicable test method, the 
information in paragraphs (a)(7)(i) through (a)(7)(vi) of this section 
may be recorded either in hard copy format, electronic format or a 
combination of the two, and the owner or operator shall maintain this 
information in a format suitable for inspection and audit purposes. This 
RATA supporting information shall include, but shall not be limited to, 
the following data elements:
    (i) For each RATA using Reference Method 2 (or its allowable 
alternatives) in appendix A to part 60 of this chapter to determine 
volumetric flow rate:
    (A) Information indicating whether or not the location meets 
requirements of Method 1 in appendix A to part 60 of this chapter; and
    (B) Information indicating whether or not the equipment passed the 
required leak checks.
    (ii) For each run of each RATA using Reference Method 2 (or its 
allowable alternatives in appendix A to part 60 of this chapter) to 
determine volumetric flow rate, record the following data elements (as 
applicable to the measurement method used):
    (A) Operating level (low, mid, high, or normal, as appropriate);
    (B) Number of reference method traverse points;
    (C) Average stack gas temperature ( deg.F);
    (D) Barometric pressure at test port (inches of mercury);
    (E) Stack static pressure (inches of H2O);
    (F) Absolute stack gas pressure (inches of mercury);
    (G) Percent CO2 and O2 in the stack gas, dry 
basis;

[[Page 300]]

    (H) CO2 and O2 reference method used;
    (I) Moisture content of stack gas (percent H2O);
    (J) Molecular weight of stack gas, dry basis (lb/lb-mole);
    (K) Molecular weight of stack gas, wet basis (lb/lb-mole);
    (L) Stack diameter (or equivalent diameter) at the test port (ft);
    (M) Average square root of velocity head of stack gas (inches of 
H2O) for the run;
    (N) Stack or duct cross-sectional area at test port 
(ft2);
    (O) Average velocity (ft/sec);
    (P) Average stack flow rate, adjusted, if applicable, for wall 
effects (scfh, wet basis);
    (Q) Flow rate reference method used;
    (R) Average velocity, adjusted for wall effects;
    (S) Calculated (site-specific) wall effects adjustment factor 
determined during the run, and, if different, the wall effects 
adjustment factor used in the calculations; and
    (T) Default wall effects adjustment factor used.
    (iii) For each traverse point of each run of each RATA using 
Reference Method 2 (or its allowable alternatives in appendix A to part 
60 of this chapter) to determine volumetric flow rate, record the 
following data elements (as applicable to the measurement method used):
    (A) Reference method probe type;
    (B) Pressure measurement device type;
    (C) Traverse point ID;
    (D) Probe or pitot tube calibration coefficient;
    (E) Date of latest probe or pitot tube calibration;
    (F) Average velocity differential pressure at traverse point (inches 
of H2O) or the average of the square roots of the velocity 
differential pressures at the traverse point ((inches of 
H2O)1/2);
    (G) TS, stack temperature at the traverse point ( deg.F);
    (H) Composite (wall effects) traverse point identifier;
    (I) Number of points included in composite traverse point;
    (J) Yaw angle of flow at traverse point (degrees);
    (K) Pitch angle of flow at traverse point (degrees);
    (L) Calculated velocity at traverse point both accounting and not 
accounting for wall effects (ft/sec); and
    (M) Probe identification number.
    (iv) For each RATA using Method 6C, 7E, or 3A in appendix A to part 
60 of this chapter to determine SO2, NOX, 
CO2, or O2 concentration:
    (A) Pollutant or diluent gas being measured;
    (B) Span of reference method analyzer;
    (C) Type of reference method system (e.g., extractive or dilution 
type);
    (D) Reference method dilution factor (dilution type systems, only);
    (E) Reference gas concentrations (zero, mid, and high gas levels) 
used for the 3-point pre-test analyzer calibration error test (or, for 
dilution type reference method systems, for the 3-point pre-test system 
calibration error test) and for any subsequent recalibrations;
    (F) Analyzer responses to the zero-, mid-, and high-level 
calibration gases during the 3-point pre-test analyzer (or system) 
calibration error test and during any subsequent recalibration(s);
    (G) Analyzer calibration error at each gas level (zero, mid, and 
high) for the 3-point pre-test analyzer (or system) calibration error 
test and for any subsequent recalibration(s) (percent of span value);
    (H) Upscale gas concentration (mid or high gas level) used for each 
pre-run or post-run system bias check or (for dilution type reference 
method systems) for each pre-run or post-run system calibration error 
check;
    (I) Analyzer response to the calibration gas for each pre-run or 
post-run system bias (or system calibration error) check;
    (J) The arithmetic average of the analyzer responses to the zero-
level gas, for each pair of pre- and post-run system bias (or system 
calibration error) checks;
    (K) The arithmetic average of the analyzer responses to the upscale 
calibration gas, for each pair of pre- and post-run system bias (or 
system calibration error) checks;
    (L) The results of each pre-run and each post-run system bias (or 
system

[[Page 301]]

calibration error) check using the zero-level gas (percentage of span 
value);
    (M) The results of each pre-run and each post-run system bias (or 
system calibration error) check using the upscale calibration gas 
(percentage of span value);
    (N) Calibration drift and zero drift of analyzer during each RATA 
run (percentage of span value);
    (O) Moisture basis of the reference method analysis;
    (P) Moisture content of stack gas, in percent, during each test run 
(if needed to convert to moisture basis of CEMS being tested);
    (Q) Unadjusted (raw) average pollutant or diluent gas concentration 
for each run;
    (R) Average pollutant or diluent gas concentration for each run, 
corrected for calibration bias (or calibration error) and, if 
applicable, corrected for moisture;
    (S) The F-factor used to convert reference method data to units of 
lb/mmBtu (if applicable);
    (T) Date(s) of the latest analyzer interference test(s);
    (U) Results of the latest analyzer interference test(s);
    (V) Date of the latest NO2 to NO conversion test (Method 
7E only);
    (W) Results of the latest NO2 to NO conversion test 
(Method 7E only); and
    (X) For each calibration gas cylinder used during each RATA, record 
the cylinder gas vendor, cylinder number, expiration date, pollutant(s) 
in the cylinder, and certified gas concentration(s).
    (v) For each test run of each moisture determination using Method 4 
in appendix A to part 60 of this chapter (or its allowable 
alternatives), whether the determination is made to support a gas RATA, 
to support a flow RATA, or to quality assure the data from a continuous 
moisture monitoring system, record the following data elements (as 
applicable to the moisture measurement method used):
    (A) Test number;
    (B) Run number;
    (C) The beginning date, hour, and minute of the run;
    (D) The ending date, hour, and minute of the run;
    (E) Unit operating level (low, mid, high, or normal, as 
appropriate);
    (F) Moisture measurement method;
    (G) Volume of H2O collected in the impingers (ml);
    (H) Mass of H2O collected in the silica gel (g);
    (I) Dry gas meter calibration factor;
    (J) Average dry gas meter temperature ( deg.F);
    (K) Barometric pressure (inches of mercury);
    (L) Differential pressure across the orifice meter (inches of 
H2O);
    (M) Initial and final dry gas meter readings (ft3);
    (N) Total sample gas volume, corrected to standard conditions 
(dscf); and
    (O) Percentage of moisture in the stack gas (percent 
H2O).
    (vi) The raw data and calculated results for any stratification 
tests performed in accordance with sections 6.5.6.1 through 6.5.6.3 of 
appendix A to this part.
    (8) For each certified continuous emission monitoring system, 
continuous opacity monitoring system, or alternative monitoring system, 
the date and description of each event which requires recertification of 
the system and the date and type of each test performed to recertify the 
system in accordance with Sec. 75.20(b).
    (9) When hardcopy relative accuracy test reports, certification 
reports, recertification reports, or semiannual or annual reports for 
gas or flow rate CEMS are required or requested under Sec. 75.60(b)(6) 
or Sec. 75.63, the reports shall include, at a minimum, the following 
elements (as applicable to the type(s) of test(s) performed):
    (i) Summarized test results.
    (ii) DAHS printouts of the CEMS data generated during the 
calibration error, linearity, cycle time, and relative accuracy tests.
    (iii) For pollutant concentration monitor or diluent monitor 
relative accuracy tests at normal operating load:
    (A) The raw reference method data from each run, i.e., the data 
under paragraph (a)(7)(iv)(Q) of this section (usually in the form of a 
computerized printout, showing a series of one-minute readings and the 
run average);

[[Page 302]]

    (B) The raw data and results for all required pre-test, post-test, 
pre-run and post-run quality assurance checks (i.e., calibration gas 
injections) of the reference method analyzers, i.e., the data under 
paragraphs (a)(7)(iv)(E) through (a)(7)(iv)(N) of this section;
    (C) The raw data and results for any moisture measurements made 
during the relative accuracy testing, i.e., the data under paragraphs 
(a)(7)(v)(A) through (a)(7)(v)(O) of this section; and
    (D) Tabulated, final, corrected reference method run data (i.e., the 
actual values used in the relative accuracy calculations), along with 
the equations used to convert the raw data to the final values and 
example calculations to demonstrate how the test data were reduced.
    (iv) For relative accuracy tests for flow monitors:
    (A) The raw flow rate reference method data, from Reference Method 2 
(or its allowable alternatives) under appendix A to part 60 of this 
chapter, including auxiliary moisture data (often in the form of 
handwritten data sheets), i.e., the data under paragraphs (a)(7)(ii)(A) 
through (a)(7)(ii)(T), paragraphs (a)(7)(iii)(A) through (a)(7)(iii)(M), 
and, if applicable, paragraphs (a)(7)(v)(A) through (a)(7)(v)(O) of this 
section; and
    (B) The tabulated, final volumetric flow rate values used in the 
relative accuracy calculations (determined from the flow rate reference 
method data and other necessary measurements, such as moisture, stack 
temperature and pressure), along with the equations used to convert the 
raw data to the final values and example calculations to demonstrate how 
the test data were reduced.
    (v) Calibration gas certificates for the gases used in the 
linearity, calibration error, and cycle time tests and for the 
calibration gases used to quality assure the gas monitor reference 
method data during the relative accuracy test audit.
    (vi) Laboratory calibrations of the source sampling equipment.
    (vii) A copy of the test protocol used for the CEMS certifications 
or recertifications, including narrative that explains any testing 
abnormalities, problematic sampling, and analytical conditions that 
required a change to the test protocol, and/or solutions to technical 
problems encountered during the testing program.
    (viii) Diagrams illustrating test locations and sample point 
locations (to verify that locations are consistent with information in 
the monitoring plan). Include a discussion of any special traversing or 
measurement scheme. The discussion shall also confirm that sample points 
satisfy applicable acceptance criteria.
    (ix) Names of key personnel involved in the test program, including 
test team members, plant contacts, agency representatives and test 
observers on site.
    (10) Whenever reference methods are used as backup monitoring 
systems pursuant to Sec. 75.20(d)(3), the owner or operator shall record 
the following information:
    (i) For each test run using Reference Method 2 (or its allowable 
alternatives in appendix A to part 60 of this chapter) to determine 
volumetric flow rate, record the following data elements (as applicable 
to the measurement method used):
    (A) Unit or stack identification number;
    (B) Reference method system and component identification numbers;
    (C) Run date and hour;
    (D) The data in paragraph (a)(7)(ii) of this section, except for 
paragraphs (a)(7)(ii)(A), (F), (H), (L) and (Q) through (T); and
    (E) The data in paragraph (a)(7)(iii), except on a run basis.
    (ii) For each reference method test run using Method 6C, 7E, or 3A 
in appendix A to part 60 of this chapter to determine SO2, 
NOX, CO2, or O2 concentration:
    (A) Unit or stack identification number;
    (B) The reference method system and component identification 
numbers;
    (C) Run number;
    (D) Run start date and hour;
    (E) Run end date and hour;
    (F) The data in paragraphs (a)(7)(iv)(B) through (I) and (L) through 
(O); and (G) Stack gas density adjustment factor (if applicable).
    (iii) For each hour of each reference method test run using Method 
6C, 7E,

[[Page 303]]

or 3A in appendix A to part 60 of this chapter to determine 
SO2, NOX, CO2, or O2 
concentration:
    (A) Unit or stack identification number;
    (B) The reference method system and component identification 
numbers;
    (C) Run number;
    (D) Run date and hour;
    (E) Pollutant or diluent gas being measured;
    (F) Unadjusted (raw) average pollutant or diluent gas concentration 
for the hour; and
    (G) Average pollutant or diluent gas concentration for the hour, 
adjusted as appropriate for moisture, calibration bias (or calibration 
error) and stack gas density.
    (11) For each other quality-assurance test or other quality 
assurance activity, the owner or operator shall record the following (as 
applicable):
    (i) Component/system identification code;
    (ii) Parameter;
    (iii) Test or activity completion date and hour;
    (iv) Test or activity description;
    (v) Test result;
    (vi) Reason for test; and
    (vii) Test code.
    (12) For each request for a quality assurance test extension or 
exemption, for any loss of exempt status, and for each single-load flow 
RATA claim pursuant to section 2.3.1.3(c)(3) of appendix B to this part, 
the owner or operator shall record the following (as applicable):
    (i) For a RATA deadline extension or exemption request:
    (A) Monitoring system identification code;
    (B) Date of last RATA;
    (C) RATA expiration date without extension;
    (D) RATA expiration date with extension;
    (E) Type of RATA extension of exemption claimed or lost;
    (F) Year to date hours of usage of fuel other than very low sulfur 
fuel;
    (G) Year to date hours of non-redundant back-up CEMS usage at the 
unit/stack; and
    (H) Quarter and year.
    (ii) For a linearity test or flow-to-load ratio test quarterly 
exemption:
    (A) Component-system identification code;
    (B) Type of test;
    (C) Basis for exemption;
    (D) Quarter and year; and
    (E) Span scale.
    (iii) For a quality assurance test extension claim based on a grace 
period:
    (A) Component-system identification code;
    (B) Type of test;
    (C) Beginning of grace period;
    (D) Date and hour of completion of required quality assurance test;
    (E) Number of unit or stack operating hours from the beginning of 
the grace period to the completion of the quality assurance test or the 
maximum allowable grace period; and
    (F) Date and hour of end of grace period.
    (iv) For a fuel flowmeter accuracy test extension:
    (A) Component-system identification code;
    (B) Date of last accuracy test;
    (C) Accuracy test expiration date without extension;
    (D) Accuracy test expiration date with extension;
    (E) Type of extension; and
    (F) Quarter and year.
    (v) For a single-load (or single-level) flow RATA claim:
    (A) Monitoring system identification code;
    (B) Ending date of last annual flow RATA;
    (C) The relative frequency (percentage) of unit or stack operation 
at each load (or operating) level (low, mid, and high) since the 
previous annual flow RATA, to the nearest 0.1 percent;
    (D) End date of the historical load (or operating level) data 
collection period; and
    (E) Indication of the load (or operating) level (low, mid or high) 
claimed for the single-load flow RATA.
    (13) An indication that data have been excluded from a periodic span 
and range evaluation of an SO2 or NOX monitor 
under section 2.1.1.5 or 2.1.2.5 of appendix A to this part and the 
reason(s) for excluding the data. For purposes of reporting under 
Sec. 75.64(a)(2), this information shall be reported with the quarterly 
report as descriptive text consistent with Sec. 75.64(g).

[[Page 304]]

    (b) Excepted monitoring systems for gas-fired and oil-fired units. 
The owner or operator shall record the applicable information in this 
section for each excepted monitoring system following the requirements 
of appendix D to this part or appendix E to this part for determining 
and recording emissions from an affected unit.
    (1) For certification and quality assurance testing of fuel 
flowmeters tested against a reference fuel flow rate (i.e., flow rate 
from another fuel flowmeter under section 2.1.5.2 of appendix D to this 
part or flow rate from a procedure according to a standard incorporated 
by reference under section 2.1.5.1 of appendix D to this part):
    (i) Unit or common pipe header identification code;
    (ii) Component and system identification codes of the fuel flowmeter 
being tested;
    (iii) Date and hour of test completion, for a test performed in-line 
at the unit;
    (iv) Date and hour of flowmeter reinstallation, for laboratory 
tests;
    (v) Test number;
    (vi) Upper range value of the fuel flowmeter;
    (vii) Flowmeter measurements during accuracy test (and mean of 
values), including units of measure;
    (viii) Reference flow rates during accuracy test (and mean of 
values), including units of measure;
    (ix) Level of fuel flowrate test during runs (low, mid or high);
    (x) Average flowmeter accuracy for low and high fuel flowrates and 
highest flowmeter accuracy of any level designated as mid, expressed as 
a percent of upper range value;
    (xi) Indicator of whether test method was a lab comparison to 
reference meter or an in-line comparison against a master meter;
    (xii) Test result (aborted, pass, or fail); and
    (xiii) Description of fuel flowmeter calibration specification or 
procedure (in the certification application, or periodically if a 
different method is used for annual quality assurance testing).
    (2) For each transmitter or transducer accuracy test for an orifice-
, nozzle-, or venturi-type flowmeter used under section 2.1.6 of 
appendix D to this part:
    (i) Component and system identification codes of the fuel flowmeter 
being tested;
    (ii) Completion date and hour of test;
    (iii) For each transmitter or transducer: transmitter or transducer 
type (differential pressure, static pressure, or temperature); the full-
scale value of the transmitter or transducer, transmitter input (pre-
calibration) prior to accuracy test, including units of measure; and 
expected transmitter output during accuracy test (reference value from 
NIST-traceable equipment), including units of measure;
    (iv) For each transmitter or transducer tested: output during 
accuracy test, including units of measure; transmitter or transducer 
accuracy as a percent of the full-scale value; and transmitter output 
level as a percent of the full-scale value;
    (v) Average flowmeter accuracy at low and high level fuel flowrates 
and highest flowmeter accuracy of any level designated as mid fuel 
flowrate, expressed as a percent of upper range value;
    (vi) Test result (pass, fail, or aborted);
    (vii) Test number; and
    (viii) Accuracy determination methodology.
    (3) For each visual inspection of the primary element or transmitter 
or transducer accuracy test for an

orifice-, nozzle-, or venturi-type flowmeter under sections 2.1.6.1 
through 2.1.6.4 of appendix D to this part:
    (i) Date of inspection/test;
    (ii) Hour of completion of inspection/test;
    (iii) Component and system identification codes of the fuel 
flowmeter being inspected/tested; and
    (iv) Results of inspection/test (pass or fail).
    (4) For fuel flowmeters that are tested using the optional fuel 
flow-to-load ratio procedures of section 2.1.7 of appendix D to this 
part:
    (i) Test data for the fuel flowmeter flow-to-load ratio or gross 
heat rate check, including:
    (A) Component/system identification code;
    (B) Calendar year and quarter;

[[Page 305]]

    (C) Indication of whether the test is for fuel flow-to-load ratio or 
gross heat rate;
    (D) Quarterly average absolute percent difference between baseline 
for fuel flow-to-load ratio (or baseline gross heat rate and hourly 
quarterly fuel flow-to-load ratios (or gross heat rate value);
    (E) Test result;
    (F) Number of hours used in the analysis;
    (G) Number of hours excluded due to co-firing;
    (H) Number of hours excluded due to ramping; and
    (I) Number of hours excluded in lower 25.0 percent range of 
operation.
    (ii) Reference data for the fuel flowmeter flow-to-load ratio or 
gross heat rate evaluation, including:
    (A) Completion date and hour of most recent primary element 
inspection;
    (B) Completion date and hour of most recent flowmeter or transmitter 
accuracy test;
    (C) Beginning date and hour of baseline period;
    (D) Completion date and hour of baseline period;
    (E) Average fuel flow rate, in 100 scfh for gas and lb/hr for oil;
    (F) Average load, in megawatts or 1000 lb/hr of steam;
    (G) Baseline fuel flow-to-load ratio, in the appropriate units of 
measure (if using fuel flow-to-load ratio);
    (H) Baseline gross heat rate if using gross heat rate, in the 
appropriate units of measure (if using gross heat rate check);
    (I) Number of hours excluded from baseline data due to ramping;
    (J) Number of hours excluded from baseline data in lower 25.0 
percent of range of operation;
    (K) Average hourly heat input rate;
    (L) Flag indicating baseline data collection is in progress and that 
fewer than four calendar quarters have elapsed since the quarter of the 
last flowmeter QA test; and
    (M) Number of hours excluded due to co-firing.
    (5) For gas-fired peaking units or oil-fired peaking units using the 
optional procedures of appendix E to this part, for each initial 
performance, periodic, or quality assurance/quality control-related 
test:
    (i) For each run of emission data, record the following data:
    (A) Unit or common pipe identification code;
    (B) Monitoring system identification code for appendix E system;
    (C) Run start date and time;
    (D) Run end date and time;
    (E) Total heat input during the run (mmBtu);
    (F) NOX emission rate (lb/mmBtu) from reference method;
    (G) Response time of the O2 and NOX reference 
method analyzers;
    (H) Type of fuel(s) combusted during the run;
    (I) Heat input rate (mmBtu/hr) during the run;
    (J) Test number;
    (K) Run number;
    (L) Operating level during the run;
    (M) NOX concentration recorded by the reference method 
during the run;
    (N) Diluent concentration recorded by the reference method during 
the run; and
    (O) Moisture measurement for the run (if applicable).
    (ii) For each run during which oil or mixed fuels are combusted 
record the following data:
    (A) Unit or common pipe identification code;
    (B) Monitoring system identification code for oil monitoring system;
    (C) Run start date and time;
    (D) Run end date and time;
    (E) Mass flow or volumetric flow of oil, in the units of measure for 
the type of fuel flowmeter;
    (F) Gross calorific value of oil in the appropriate units of 
measure;
    (G) Density of fuel oil in the appropriate units of measure (if 
density is used to convert oil volume to mass);
    (H) Hourly heat input (mmBtu) during run from oil;
    (I) Test number;
    (J) Run number; and
    (K) Operating level during the run.
    (iii) For each run during which gas or mixed fuels are combusted 
record the following data:
    (A) Unit or common pipe identification code;
    (B) Monitoring system identification code for gas monitoring system;

[[Page 306]]

    (C) Run start date and time;
    (D) Run end date and time;
    (E) Volumetric flow of gas (100 scf);
    (F) Gross calorific value of gas (Btu/100 scf);
    (G) Hourly heat input (mmBtu) during run from gas;
    (H) Test number;
    (I) Run number; and
    (J) Operating level during the run.
    (iv) For each operating level at which runs were performed:
    (A) Completion date and time of last run for operating level;
    (B) Type of fuel(s) combusted during test;
    (C) Average heat input rate at that operating level (mmBtu/hr);
    (D) Arithmetic mean of NOX emission rates from reference 
method run at this level;
    (E) F-factor used in calculations of NOX emission rate at 
that operating level;
    (F) Unit operating parametric data related to NOX 
formation for that unit type (e.g., excess O2 level, water/
fuel ratio);
    (G) Test number; and
    (H) Operating level for runs.
    (c) For units with add-on SO2 or NOX emission 
controls following the provisions of Sec. 75.34(a)(1) or (a)(2), the 
owner or operator shall keep the following records on-site in the 
quality assurance/quality control plan required by section 1 of appendix 
B to this part:
    (1) A list of operating parameters for the add-on emission controls, 
including parameters in Sec. 75.58(b), appropriate to the particular 
installation of add-on emission controls; and
    (2) The range of each operating parameter in the list that indicates 
the add-on emission controls are properly operating.
    (d) Excepted monitoring for low mass emissions units under 
Sec. 75.19(c)(1)(iv). For oil-and gas-fired units using the optional 
SO2, NOX and CO2 emissions calculations 
for low mass emission units under Sec. 75.19, the owner or operator 
shall record the following information for tests performed to determine 
a fuel and unit-specific default as provided in Sec. 75.19(c)(1)(iv):
    (1) For each run of each test performed using the procedures of 
section 2.1 of appendix E to this part, record the following data:
    (i) Unit or common pipe identification code;
    (ii) Run start date and time;
    (iii) Run end date and time;
    (iv) NOX emission rate (lb/mmBtu) from reference method;
    (v) Response time of the O2 and NOX reference 
method analyzers;
    (vi) Type of fuel(s) combusted during the run;
    (vii) Test number;
    (viii) Run number;
    (ix) Operating level during the run;
    (x) NOX concentration recorded by the reference method 
during the run;
    (xi) Diluent concentration recorded by the reference method during 
the run; and
    (xii) Moisture measurement for the run (if applicable).
    (2) For each single-load or multiple-load appendix E test, record 
the following:
    (i) The three-run average NOX emission rate for each load 
level;
    (ii) An indicator that the average NOX emission rate is 
the highest NOX average emission rate recorded at any load 
level of the test (if appropriate);
    (iii) The default NOX emission rate (highest three-run 
average NOX emission rate at any load level), multiplied by 
1.15, if appropriate;
    (iv) An indicator that the add-on NOX emission controls 
were operating or not operating during each run of the test; and
    (v) Parameter data indicating the use and efficacy of control 
equipment during the test.
    (3) For each unit in a group of identical units qualifying for 
reduced testing under Sec. 75.19(c)(1)(iv)(B), record the following 
data:
    (i) The unique group identification code assigned to the group. This 
code must include the ORIS code of one of the units in the group;
    (ii) The ORIS code or facility identification code for the unit;
    (iii) The plant name of the facility at which the unit is located, 
consistent with the facility's monitoring plan;
    (iv) The identification code for the unit, consistent with the 
facility's monitoring plan;

[[Page 307]]

    (v) A record of whether or not the unit underwent fuel and unit-
specific testing for purposes of establishing a fuel and unit-specific 
NOX emission rate for purposes of Sec. 75.19;
    (vi) The completion date of the fuel and unit-specific test 
performed for purposes of establishing a fuel and unit-specific 
NOX emission rate for purposes of Sec. 75.19;
    (vii) The fuel and unit-specific NOX default rate 
established for the group of identical units under Sec. 75.19;
    (viii) The type of fuel combusted for the units during testing and 
represented by the resulting default NOX emission rate;
    (ix) The control status for the units during testing and represented 
by the resulting default NOX emission rate;
    (x) Documentation supporting the qualification of all units in the 
group for reduced testing based on the criteria established in 
Secs. 75.19(c)(1)(iv)(B)(1); and
    (xi) Purpose of group tests.

[64 FR 28614, May 26, 1999, as amended at 67 FR 40442, June 12, 2002]