[Code of Federal Regulations] [Title 40, Volume 14] [Revised as of July 1, 2003] From the U.S. Government Printing Office via GPO Access [CITE: 40CFR75.62] [Page 311] TITLE 40--PROTECTION OF ENVIRONMENT CHAPTER I--ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) PART 75--CONTINUOUS EMISSION MONITORING--Table of Contents Subpart G--Reporting Requirements Sec. 75.62 Monitoring plan submittals. (a) Submission--(1) Electronic. Using the format specified in paragraph (c) of this section, the designated representative for an affected unit shall submit a complete, electronic, up-to-date monitoring plan file (except for hardcopy portions identified in paragraph (a)(2) of this section) to the Administrator as follows: no later than 45 days prior to the initial certification tests; at the time of each certification or recertification application submission; in each electronic quarterly report; and whenever an update of the electronic monitoring plan information is required, either under Sec. 75.53(b) or elsewhere in this part. (2) Hardcopy. The designated representative shall submit all of the hardcopy information required under Sec. 75.53 to the appropriate EPA Regional Office and the appropriate State and/or local air pollution control agency prior to initial certification. Thereafter, the designated representative shall submit hardcopy information only if that portion of the monitoring plan is revised. The designated representative shall submit the required hardcopy information as follows: no later than 45 days prior to the initial certification test; with any certification or recertification application, if a hardcopy monitoring plan change is associated with the certification or recertification event; and within 30 days of any other event with which a hardcopy monitoring plan change is associated, pursuant to Sec. 75.53(b). Electronic submittal of all monitoring plan information, including hardcopy portions, is permissible provided that a paper copy of the hardcopy portions can be furnished upon request. (b) Contents. Monitoring plans shall contain the information specified in Sec. 75.53 of this part. (c) Format. The designated representative shall submit each monitoring plan in a format specified by the Administrator. [58 FR 3701, Jan. 11, 1993, as amended at 60 FR 26539, May 17, 1995; 64 FR 28621, May 26, 1999; 67 FR 40443, June 12, 2002]