[Code of Federal Regulations]
[Title 40, Volume 14]
[Revised as of July 1, 2003]
From the U.S. Government Printing Office via GPO Access
[CITE: 40CFR76.7]
[Page 443-444]
TITLE 40--PROTECTION OF ENVIRONMENT
CHAPTER I--ENVIRONMENTAL PROTECTION AGENCY (CONTINUED)
PART 76--ACID RAIN NITROGEN OXIDES EMISSION REDUCTION PROGRAM--Table of Contents
Sec. 76.7 Revised NOX emission limitations for Group 1, Phase II
boilers.
(a) Beginning January 1, 2000, the owner or operator of a Group 1,
Phase
[[Page 444]]
II coal-fired utility unit with a tangentially fired boiler or a dry
bottom wall-fired boiler shall not discharge, or allow to be discharged,
emissions of NOX to the atmosphere in excess of the following
limits, except as provided in Secs. 76.8, 76.10, or 76.11:
(1) 0.40 lb/mmBtu of heat input on an annual average basis for
tangentially fired boilers.
(2) 0.46 lb/ mmBtu of heat input on an annual average basis for dry
bottom wall-fired boilers (other than units applying cell burner
technology).
(b) The owner or operator shall determine the annual average
NOX emission rate, in lb/mmBtu, using the methods and
procedures specified in part 75 of this chapter.
[60 FR 18761, Apr. 13, 1995, as amended at 61 FR 67163, Dec. 19, 1996]