[Code of Federal Regulations] [Title 46, Volume 7] [Revised as of October 1, 2003] From the U.S. Government Printing Office via GPO Access [CITE: 46CFR174.065] [Page 172-173] TITLE 46--SHIPPING CHAPTER I--COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) PART 174--SPECIAL RULES PERTAINING TO SPECIFIC VESSEL TYPES--Table of Contents Subpart C--Special Rules Pertaining to Mobile Offshore Drilling Units Sec. 174.065 Damage stability requirements. (a) Each unit must be designed so that, while in each of its normal operating conditions and severe storm conditions, its final equilibrium waterline would remain below the lowest edge of any opening through which additional flooding could occur if the unit were subjected simultaneously to-- (1) Damage causing flooding described in Secs. 174.075 through 174.085; and (2) A wind heeling moment calculated in accordance with Sec. 174.055(b) using a wind velocity of 50 knots (25.8 meters per second). (b) Each unit must have a means to close off each pipe, ventilation system, and trunk in each compartment described in Sec. 174.080 or Sec. 174.085 if any portion of the pipe, ventilation system, or [[Page 173]] trunk is within 5 feet (1.5 meters) of the hull.