[Code of Federal Regulations] [Title 46, Volume 7] [Revised as of October 1, 2003] From the U.S. Government Printing Office via GPO Access [CITE: 46CFR174.090] [Page 173] TITLE 46--SHIPPING CHAPTER I--COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) PART 174--SPECIAL RULES PERTAINING TO SPECIFIC VESSEL TYPES--Table of Contents Subpart C--Special Rules Pertaining to Mobile Offshore Drilling Units Sec. 174.090 Permeability of spaces. When doing the calculations required in Sec. 174.065-- (a) The permeability of a floodable space, other than a machinery space, must be as listed in Table 174.090; and (b) Calculations in which a machinery space is treated as a floodable space must be based on an assumed machinery space permeability of 85%, unless the use of an assumed permeability of less than 85% is justified in detail. Table 174.090--Permeability ------------------------------------------------------------------------ Spaces and tanks Permeability (percent) ------------------------------------------------------------------------ Storeroom spaces........................... 60. Accommodation spaces....................... 95. Voids...................................... 95. Consumable liquid tanks.................... 95 or 0.\1\ Other liquid tanks......................... 95 or 0.\2\ ------------------------------------------------------------------------ \1\ Whichever results in the more disabling condition. \2\ If tanks are partially filled, the permeability must be determined from the actual density and amount of liquid carried.