[Code of Federal Regulations]
[Title 46, Volume 7]
[Revised as of October 1, 2003]
From the U.S. Government Printing Office via GPO Access
[CITE: 46CFR183.210]

[Page 288]
 
                           TITLE 46--SHIPPING
 
   CHAPTER I--COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED)
 
PART 183--ELECTRICAL INSTALLATION--Table of Contents
 
                     Subpart B--General Requirements
 
Sec. 183.210  Protection from wet and corrosive environments.

    (a) Electrical equipment used in the following locations must be 
dripproof:
    (1) A machinery space;
    (2) A location normally exposed to splashing, water washdown, or 
other wet conditions within a galley, a laundry, or a public washroom or 
toilet room that has a bath or shower; or
    (3) Another space with a similar moisture level.
    (b) Electrical equipment exposed to the weather must be watertight.
    (c) Electrical equipment exposed to corrosive environments must be 
of suitable construction and corrosion-resistant.