[Code of Federal Regulations]
[Title 47, Volume 2]
[Revised as of October 1, 2003]
From the U.S. Government Printing Office via GPO Access
[CITE: 47CFR24.133]
[Page 236]
TITLE 47--TELECOMMUNICATION
CHAPTER I--FEDERAL COMMUNICATIONS
COMMISSION (CONTINUED)
PART 24--PERSONAL COMMUNICATIONS SERVICES--Table of Contents
Subpart D--Narrowband PCS
Sec. 24.133 Emission limits.
(a) The power of any emission shall be attenuated below the
transmitter power (P), as measured in accordance with Sec. 24.132(f), in
accordance with the following schedule:
(1) For transmitters authorized a bandwidth greater than 10 kHz:
(i) On any frequency outside the authorized bandwidth and removed
from the edge of the authorized bandwidth by a displacement frequency
(fd in kHz) of up to and including 40 kHz: at least 116
Log10 ((fd+10)/6.1) decibels or 50 plus 10
Log10 (P) decibels or 70 decibels, whichever is the lesser
attenuation;
(ii) On any frequency outside the authorized bandwidth and removed
from the edge of the authorized bandwidth by a displacement frequency
(fd in kHz) of more than 40 kHz: at least 43+10
Log10 (P) decibels or 80 decibels, whichever is the lesser
attenuation.
(2) For transmitters authorized a bandwidth of 10 kHz:
(i) On any frequency outside the authorized bandwidth and removed
from the edge of the authorized bandwidth by a displacement frequency
(fd in kHz) of up to and including 20 kHz: at least 116 x
Log10 ((fd+5)/3.05) decibels or
50+10xLog10 (P) decibels or 70 decibels, whichever is the
lesser attenuation;
(ii) On any frequency outside the authorized bandwidth and removed
from the edge of the authorized bandwidth by a displacement frequency
(fd in kHz) of more than 20 kHz: at least 43+10 Log
10 (P) decibels or 80 decibels, whichever is the lesser
attenuation.
(b) The measurements of emission power can be expressed in peak or
average values provided they are expressed in the same parameters as the
transmitter power.
(c) When an emission outside of the authorized bandwidth causes
harmful interference, the Commission may, at its discretion, require
greater attenuation than specified in this section.
(d) The following minimum spectrum analyzer resolution bandwidth
settings will be used: 300 Hz when showing compliance with paragraphs
(a)(1)(i) and (a)(2)(i) of this section; and 30 kHz when showing
compliance with paragraphs (a)(1)(ii) and (a)(2)(ii) of this section.
[58 FR 59183, Nov. 8, 1993. Redesignated at 59 FR 18499, April 19, 1994,
as amended at 59 FR 14119, Mar. 25, 1994; 66 FR 10968, Feb. 21, 2001]