Sec.  173.121  Class 3--Assignment of packing group.

    (a) The packing group of a Class 3 material is as assigned in column 
5 of the Sec.  172.101 table. When the Sec.  172.101 table provides more 
than one packing group for a hazardous material, the packing group shall 
be determined by applying the following criteria:

----------------------------------------------------------------------------------------------------------------
             Packing group                     Flash point (closed-cup)              Initial boiling point
----------------------------------------------------------------------------------------------------------------
I.....................................  .....................................  <=35[deg]C (95[deg]F)

[[Page 480]]


II....................................  <23[deg]C (73[deg]F).................  35[deg]C (95[deg]F)
III...................................  =23[deg]C, <=60.5[deg]C     35[deg]C (95[deg]F)
                                         (=73[deg]F, <=141[deg]F).
----------------------------------------------------------------------------------------------------------------

    (b) Criteria for inclusion of viscous Class 3 materials in Packing 
Group III. (1) Viscous Class 3 materials in Packing Group II with a 
flash point of less than 23 [deg]C (73 [deg]F) may be grouped in Packing 
Group III provided that--
    (i) Less than 3 percent of the clear solvent layer separates in the 
solvent separation test;
    (ii) The mixture does not contain any substances with a primary or a 
subsidiary risk of Division 6.1 or Class 8;
    (iii) The capacity of the packaging is not more than 30 L (7.9 
gallons); and
    (iv) The viscosity and flash point are in accordance with the 
following table:

------------------------------------------------------------------------
                                          Jet
        Flow time t in seconds         diameter      Flash point c.c.
                                         in mm
------------------------------------------------------------------------
20